Case Analysis of Several Atypical Faults of Large Turbo-Generator Set
This paper presents several atypical fault cases of large steam generator set caused by installation or maintenance mistakes in recent years. The fault symptoms, causes and consequences are described and analyzed in details, which involved axial displacement overrun, sudden change of turbine output...