Case Analysis of Several Atypical Faults of Large Turbo-Generator Set

This paper presents several atypical fault cases of large steam generator set caused by installation or maintenance mistakes in recent years. The fault symptoms, causes and consequences are described and analyzed in details, which involved axial displacement overrun, sudden change of turbine output...

Full description

Saved in:
Bibliographic Details
Main Authors: Xueyan ZHANG, Jie QU, Guoan HE, Pengbo ZHU, Guangzheng JIANG, Bo PAN
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2020-12-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202003147
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This paper presents several atypical fault cases of large steam generator set caused by installation or maintenance mistakes in recent years. The fault symptoms, causes and consequences are described and analyzed in details, which involved axial displacement overrun, sudden change of turbine output and thermal parameters, or abnormal vibrations. The analytical procedures and experience of the cases can provide reference for the analysis of faults and accidents as well as the installation and maintenance guide of the unit in the future.