Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy Range
As it is important to obtain accurate analytical result in an experimental research, this required quality control of the experimental system. Gamma spectrometry system can be used in a variety of different fields such as radiation and medical physics. In this paper the absolute efficiency, peak to...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2014-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2014/186798 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832564149827141632 |
---|---|
author | I. Akkurt K. Gunoglu S. S. Arda |
author_facet | I. Akkurt K. Gunoglu S. S. Arda |
author_sort | I. Akkurt |
collection | DOAJ |
description | As it is important to obtain accurate analytical result in an experimental research, this required quality control of the experimental system. Gamma spectrometry system can be used in a variety of different fields such as radiation and medical physics. In this paper the absolute efficiency, peak to valley ratio, and energy resolution of a 3′′×3′′ NaI(Tl) detector were determined experimentally for 511, 662, 835, 1173, 1275, and 1332 keV photon energies obtained from 22Na, 54Mn, 60Co, and 137Cs radioactive sources. |
format | Article |
id | doaj-art-d3a1fd64de7a453bada731c9b4a366ac |
institution | Kabale University |
issn | 1687-6075 1687-6083 |
language | English |
publishDate | 2014-01-01 |
publisher | Wiley |
record_format | Article |
series | Science and Technology of Nuclear Installations |
spelling | doaj-art-d3a1fd64de7a453bada731c9b4a366ac2025-02-03T01:11:39ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832014-01-01201410.1155/2014/186798186798Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy RangeI. Akkurt0K. Gunoglu1S. S. Arda2Fen-Edebiyat Fakultesi Fizik Bol, Suleyman Demirel University, 32260 Isparta, TurkeyTeknşk Bil. MYO, Suleyman Demirel University, 32260 Isparta, TurkeyFen-Edebiyat Fakultesi Fizik Bol, Suleyman Demirel University, 32260 Isparta, TurkeyAs it is important to obtain accurate analytical result in an experimental research, this required quality control of the experimental system. Gamma spectrometry system can be used in a variety of different fields such as radiation and medical physics. In this paper the absolute efficiency, peak to valley ratio, and energy resolution of a 3′′×3′′ NaI(Tl) detector were determined experimentally for 511, 662, 835, 1173, 1275, and 1332 keV photon energies obtained from 22Na, 54Mn, 60Co, and 137Cs radioactive sources.http://dx.doi.org/10.1155/2014/186798 |
spellingShingle | I. Akkurt K. Gunoglu S. S. Arda Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy Range Science and Technology of Nuclear Installations |
title | Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy Range |
title_full | Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy Range |
title_fullStr | Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy Range |
title_full_unstemmed | Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy Range |
title_short | Detection Efficiency of NaI(Tl) Detector in 511–1332 keV Energy Range |
title_sort | detection efficiency of nai tl detector in 511 1332 kev energy range |
url | http://dx.doi.org/10.1155/2014/186798 |
work_keys_str_mv | AT iakkurt detectionefficiencyofnaitldetectorin5111332kevenergyrange AT kgunoglu detectionefficiencyofnaitldetectorin5111332kevenergyrange AT ssarda detectionefficiencyofnaitldetectorin5111332kevenergyrange |