Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression

This rapid method for determining the degree of degradation of frying rapeseed oils uses Fourier-transform infrared (FTIR) spectroscopy combined with partial least-squares (PLS) regression. One hundred and fifty-six frying oil samples that degraded to different degrees by frying potatoes were scanne...

Full description

Saved in:
Bibliographic Details
Main Authors: Jie Yu Chen, Han Zhang, Jinkui Ma, Tomohiro Tuchiya, Yelian Miao
Format: Article
Language:English
Published: Wiley 2015-01-01
Series:International Journal of Analytical Chemistry
Online Access:http://dx.doi.org/10.1155/2015/185367
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832558134289235968
author Jie Yu Chen
Han Zhang
Jinkui Ma
Tomohiro Tuchiya
Yelian Miao
author_facet Jie Yu Chen
Han Zhang
Jinkui Ma
Tomohiro Tuchiya
Yelian Miao
author_sort Jie Yu Chen
collection DOAJ
description This rapid method for determining the degree of degradation of frying rapeseed oils uses Fourier-transform infrared (FTIR) spectroscopy combined with partial least-squares (PLS) regression. One hundred and fifty-six frying oil samples that degraded to different degrees by frying potatoes were scanned by an FTIR spectrometer using attenuated total reflectance (ATR). PLS regression with full cross validation was used for the prediction of acid value (AV) and total polar compounds (TPC) based on raw, first, and second derivative FTIR spectra (4000–650 cm−1). The precise calibration model based on the second derivative FTIR spectra shows that the coefficients of determination for calibration (R2) and standard errors of cross validation (SECV) were 0.99 and 0.16 mg KOH/g and 0.98 and 1.17% for AV and TPC, respectively. The accuracy of the calibration model, tested using the validation set, yielded standard errors of prediction (SEP) of 0.16 mg KOH/g and 1.10% for AV and TPC, respectively. Therefore, the degradation of frying oils can be accurately measured using FTIR spectroscopy combined with PLS regression.
format Article
id doaj-art-d24ca8e9fef246459cf03afe946dc0bb
institution Kabale University
issn 1687-8760
1687-8779
language English
publishDate 2015-01-01
publisher Wiley
record_format Article
series International Journal of Analytical Chemistry
spelling doaj-art-d24ca8e9fef246459cf03afe946dc0bb2025-02-03T01:33:09ZengWileyInternational Journal of Analytical Chemistry1687-87601687-87792015-01-01201510.1155/2015/185367185367Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares RegressionJie Yu Chen0Han Zhang1Jinkui Ma2Tomohiro Tuchiya3Yelian Miao4Faculty of Bioresource Sciences, Akita Prefectural University, Akita 010-0195, JapanFaculty of Bioresource Sciences, Akita Prefectural University, Akita 010-0195, JapanSchool of Chemistry & Chemical Engineering, Zhaoqing University, Zhaoqing 526061, ChinaFaculty of Bioresource Sciences, Akita Prefectural University, Akita 010-0195, JapanCollege of Food and Light Industrial Engineering, Nanjing University of Technology, Nanjing 211800, ChinaThis rapid method for determining the degree of degradation of frying rapeseed oils uses Fourier-transform infrared (FTIR) spectroscopy combined with partial least-squares (PLS) regression. One hundred and fifty-six frying oil samples that degraded to different degrees by frying potatoes were scanned by an FTIR spectrometer using attenuated total reflectance (ATR). PLS regression with full cross validation was used for the prediction of acid value (AV) and total polar compounds (TPC) based on raw, first, and second derivative FTIR spectra (4000–650 cm−1). The precise calibration model based on the second derivative FTIR spectra shows that the coefficients of determination for calibration (R2) and standard errors of cross validation (SECV) were 0.99 and 0.16 mg KOH/g and 0.98 and 1.17% for AV and TPC, respectively. The accuracy of the calibration model, tested using the validation set, yielded standard errors of prediction (SEP) of 0.16 mg KOH/g and 1.10% for AV and TPC, respectively. Therefore, the degradation of frying oils can be accurately measured using FTIR spectroscopy combined with PLS regression.http://dx.doi.org/10.1155/2015/185367
spellingShingle Jie Yu Chen
Han Zhang
Jinkui Ma
Tomohiro Tuchiya
Yelian Miao
Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression
International Journal of Analytical Chemistry
title Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression
title_full Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression
title_fullStr Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression
title_full_unstemmed Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression
title_short Determination of the Degree of Degradation of Frying Rapeseed Oil Using Fourier-Transform Infrared Spectroscopy Combined with Partial Least-Squares Regression
title_sort determination of the degree of degradation of frying rapeseed oil using fourier transform infrared spectroscopy combined with partial least squares regression
url http://dx.doi.org/10.1155/2015/185367
work_keys_str_mv AT jieyuchen determinationofthedegreeofdegradationoffryingrapeseedoilusingfouriertransforminfraredspectroscopycombinedwithpartialleastsquaresregression
AT hanzhang determinationofthedegreeofdegradationoffryingrapeseedoilusingfouriertransforminfraredspectroscopycombinedwithpartialleastsquaresregression
AT jinkuima determinationofthedegreeofdegradationoffryingrapeseedoilusingfouriertransforminfraredspectroscopycombinedwithpartialleastsquaresregression
AT tomohirotuchiya determinationofthedegreeofdegradationoffryingrapeseedoilusingfouriertransforminfraredspectroscopycombinedwithpartialleastsquaresregression
AT yelianmiao determinationofthedegreeofdegradationoffryingrapeseedoilusingfouriertransforminfraredspectroscopycombinedwithpartialleastsquaresregression