Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual Irrigation and Aspiration System of Phaco Machine in Immature Cataract
Seventy-eight eye of 65 patients were enrolled in this retrospective clinical study. Two-side ports are made with a 23-gauge stiletto knife. The irrigation handpiece is introduced into the anterior chamber through one side port and 27-gauge cystotome is introduced through the other one. Anterior cap...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Journal of Ophthalmology |
Online Access: | http://dx.doi.org/10.1155/2013/921646 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832548493389987840 |
---|---|
author | Huseyin Oksuz Mutlu C. Daglioglu Mesut Coskun Özgür İlhan Esra Ayhan Tuzcu Nilufer Ilhan Emre Ayıntap Uğurcan Keskin İbrahim Taşkın |
author_facet | Huseyin Oksuz Mutlu C. Daglioglu Mesut Coskun Özgür İlhan Esra Ayhan Tuzcu Nilufer Ilhan Emre Ayıntap Uğurcan Keskin İbrahim Taşkın |
author_sort | Huseyin Oksuz |
collection | DOAJ |
description | Seventy-eight eye of 65 patients were enrolled in this retrospective clinical study. Two-side ports are made with a 23-gauge stiletto knife. The irrigation handpiece is introduced into the anterior chamber through one side port and 27-gauge cystotome is introduced through the other one. Anterior capsular flap is created with cystotome. The capsular flap is vacuumed with a 25-gauge visco elastic’s cannula, which connected to the phaco machine vacuum. The continuous circular capsulorhexis (CCC) is completed with the using bimanual irrigation and aspiration system of phaco machine. Vacuum-assisted CCC technique was used in 78 cases of uncomplicated immature senile cataracts. All cases were done under sub-Tenon’s anesthesia. A complete CCC was achieved in all cases. Performing CCC with our technique is easy, safe, and cheap. It may be an alternative method to CCC by using OVD and forceps. |
format | Article |
id | doaj-art-cf460c1c0b824cf2ac095f1fcb3b89e2 |
institution | Kabale University |
issn | 2090-004X 2090-0058 |
language | English |
publishDate | 2013-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Ophthalmology |
spelling | doaj-art-cf460c1c0b824cf2ac095f1fcb3b89e22025-02-03T06:14:03ZengWileyJournal of Ophthalmology2090-004X2090-00582013-01-01201310.1155/2013/921646921646Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual Irrigation and Aspiration System of Phaco Machine in Immature CataractHuseyin Oksuz0Mutlu C. Daglioglu1Mesut Coskun2Özgür İlhan3Esra Ayhan Tuzcu4Nilufer Ilhan5Emre Ayıntap6Uğurcan Keskin7İbrahim Taşkın8Department of Ophthalmology, Medical Faculty, Mustafa Kemal University, 31400 Hatay, TurkeyDepartment of Ophthalmology, Medical Faculty, Mustafa Kemal University, 31400 Hatay, TurkeyDepartment of Ophthalmology, Medical Faculty, Mustafa Kemal University, 31400 Hatay, TurkeyDepartment of Ophthalmology, Medical Faculty, Mustafa Kemal University, 31400 Hatay, TurkeyDepartment of Ophthalmology, Medical Faculty, Mustafa Kemal University, 31400 Hatay, TurkeyDepartment of Ophthalmology, Medical Faculty, Mustafa Kemal University, 31400 Hatay, TurkeyDepartment of Ophthalmology, Medical Faculty, Bezmialem Vakif University, Istanbul, TurkeyDepartment of Ophthalmology, Medical Faculty, Mustafa Kemal University, 31400 Hatay, TurkeyPrivate Maya Eye Center, Adana, TurkeySeventy-eight eye of 65 patients were enrolled in this retrospective clinical study. Two-side ports are made with a 23-gauge stiletto knife. The irrigation handpiece is introduced into the anterior chamber through one side port and 27-gauge cystotome is introduced through the other one. Anterior capsular flap is created with cystotome. The capsular flap is vacuumed with a 25-gauge visco elastic’s cannula, which connected to the phaco machine vacuum. The continuous circular capsulorhexis (CCC) is completed with the using bimanual irrigation and aspiration system of phaco machine. Vacuum-assisted CCC technique was used in 78 cases of uncomplicated immature senile cataracts. All cases were done under sub-Tenon’s anesthesia. A complete CCC was achieved in all cases. Performing CCC with our technique is easy, safe, and cheap. It may be an alternative method to CCC by using OVD and forceps.http://dx.doi.org/10.1155/2013/921646 |
spellingShingle | Huseyin Oksuz Mutlu C. Daglioglu Mesut Coskun Özgür İlhan Esra Ayhan Tuzcu Nilufer Ilhan Emre Ayıntap Uğurcan Keskin İbrahim Taşkın Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual Irrigation and Aspiration System of Phaco Machine in Immature Cataract Journal of Ophthalmology |
title | Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual
Irrigation and Aspiration System of Phaco Machine in Immature Cataract |
title_full | Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual
Irrigation and Aspiration System of Phaco Machine in Immature Cataract |
title_fullStr | Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual
Irrigation and Aspiration System of Phaco Machine in Immature Cataract |
title_full_unstemmed | Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual
Irrigation and Aspiration System of Phaco Machine in Immature Cataract |
title_short | Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual
Irrigation and Aspiration System of Phaco Machine in Immature Cataract |
title_sort | vacuum assisted continuous circular capsulorhexis using bimanual irrigation and aspiration system of phaco machine in immature cataract |
url | http://dx.doi.org/10.1155/2013/921646 |
work_keys_str_mv | AT huseyinoksuz vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT mutlucdaglioglu vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT mesutcoskun vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT ozgurilhan vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT esraayhantuzcu vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT niluferilhan vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT emreayıntap vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT ugurcankeskin vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract AT ibrahimtaskın vacuumassistedcontinuouscircularcapsulorhexisusingbimanualirrigationandaspirationsystemofphacomachineinimmaturecataract |