Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing
Because a pool scrubbing is important for reducing radioactive aerosols to the environment for a nuclear reactor in a severe accident situation, many researches have been performed. However, decontamination factor (DF) dependence on aerosol concentration was seldom considered in an aerosol number co...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2019-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2019/1743982 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832561665553465344 |
---|---|
author | Haomin Sun Yasuteru Sibamoto Yuria Okagaki Taisuke Yonomoto |
author_facet | Haomin Sun Yasuteru Sibamoto Yuria Okagaki Taisuke Yonomoto |
author_sort | Haomin Sun |
collection | DOAJ |
description | Because a pool scrubbing is important for reducing radioactive aerosols to the environment for a nuclear reactor in a severe accident situation, many researches have been performed. However, decontamination factor (DF) dependence on aerosol concentration was seldom considered in an aerosol number concentration with limited aerosol coagulation. To investigate an existence of DF dependence on the concentration, DF in a pool scrubbing with 2.4 m water submergence was derived from aerosol measurements by light scattering aerosol spectrometers. It was observed that DF increased monotonically with decreasing particle number concentration in a constant thermohydraulic condition: a gradual increase from 10 to 32 in the range of 1.3×1011 - 8.0×1011/m3 at the inlet and a significant increase from 32 to 77 in the range of 3.6×1010 - 1.3×1011/m3. Two validation experiments were conducted in the range with the gradual DF increase to confirm whether the DF dependence is a real pool scrubbing phenomenon. In addition, characteristics of the DF dependence in different water submergences were investigated experimentally. It was found that the DF dependence became more significant in higher water submergence. Significant DF dependence was observed in the condition of the water submergence higher than 1.6 m and the inlet particle number concentration less than around 1×1011 /m3. It is recommended to perform further analysis for the DF dependence mainly in such condition since it could make a difference to both experiment and model of the pool scrubbing. |
format | Article |
id | doaj-art-cf24146a07b44ad685e6b8551230ef34 |
institution | Kabale University |
issn | 1687-6075 1687-6083 |
language | English |
publishDate | 2019-01-01 |
publisher | Wiley |
record_format | Article |
series | Science and Technology of Nuclear Installations |
spelling | doaj-art-cf24146a07b44ad685e6b8551230ef342025-02-03T01:24:32ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832019-01-01201910.1155/2019/17439821743982Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool ScrubbingHaomin Sun0Yasuteru Sibamoto1Yuria Okagaki2Taisuke Yonomoto3Nuclear Safety Research Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, JapanNuclear Safety Research Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, JapanNuclear Safety Research Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, JapanNuclear Safety Research Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, JapanBecause a pool scrubbing is important for reducing radioactive aerosols to the environment for a nuclear reactor in a severe accident situation, many researches have been performed. However, decontamination factor (DF) dependence on aerosol concentration was seldom considered in an aerosol number concentration with limited aerosol coagulation. To investigate an existence of DF dependence on the concentration, DF in a pool scrubbing with 2.4 m water submergence was derived from aerosol measurements by light scattering aerosol spectrometers. It was observed that DF increased monotonically with decreasing particle number concentration in a constant thermohydraulic condition: a gradual increase from 10 to 32 in the range of 1.3×1011 - 8.0×1011/m3 at the inlet and a significant increase from 32 to 77 in the range of 3.6×1010 - 1.3×1011/m3. Two validation experiments were conducted in the range with the gradual DF increase to confirm whether the DF dependence is a real pool scrubbing phenomenon. In addition, characteristics of the DF dependence in different water submergences were investigated experimentally. It was found that the DF dependence became more significant in higher water submergence. Significant DF dependence was observed in the condition of the water submergence higher than 1.6 m and the inlet particle number concentration less than around 1×1011 /m3. It is recommended to perform further analysis for the DF dependence mainly in such condition since it could make a difference to both experiment and model of the pool scrubbing.http://dx.doi.org/10.1155/2019/1743982 |
spellingShingle | Haomin Sun Yasuteru Sibamoto Yuria Okagaki Taisuke Yonomoto Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing Science and Technology of Nuclear Installations |
title | Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing |
title_full | Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing |
title_fullStr | Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing |
title_full_unstemmed | Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing |
title_short | Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing |
title_sort | experimental investigation of decontamination factor dependence on aerosol concentration in pool scrubbing |
url | http://dx.doi.org/10.1155/2019/1743982 |
work_keys_str_mv | AT haominsun experimentalinvestigationofdecontaminationfactordependenceonaerosolconcentrationinpoolscrubbing AT yasuterusibamoto experimentalinvestigationofdecontaminationfactordependenceonaerosolconcentrationinpoolscrubbing AT yuriaokagaki experimentalinvestigationofdecontaminationfactordependenceonaerosolconcentrationinpoolscrubbing AT taisukeyonomoto experimentalinvestigationofdecontaminationfactordependenceonaerosolconcentrationinpoolscrubbing |