Accuracy-dependent dose-constraints and dose-based safety margins for organs-at-risk in radiotherapy
Background and purpose: Geometrical uncertainties in radiotherapy are generally accounted for by margins for tumors, but their effect on organs-at-risk (OARs) is often ignored. We developed a model that incorporates dose- and geometry-based uncertainties in OAR planning using dose constraints. Mater...
Saved in:
Main Authors: | Joep C. Stroom, Sandra C. Vieira, Carlo Greco, Sebastiaan M.J.J.G. Nijsten |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-01-01
|
Series: | Physics and Imaging in Radiation Oncology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405631625000181 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Spatial accuracy of dose delivery significantly impacts the planning target volume margin in linear accelerator-based intracranial stereotactic radiosurgery
by: Yuta Takahashi, et al.
Published: (2025-01-01) -
Comparative Analysis of Postoperative Radiotherapy Dose Escalation in Oral Cavity Cancer Patients with Positive Margins: A Propensity Score-Matched Study
by: Rashmi Sarawagi, et al. -
Modeling dose uncertainty in cone-beam computed tomography: Predictive approach for deep learning-based synthetic computed tomography generation
by: Cédric Hémon, et al.
Published: (2025-01-01) -
Effect of Mycorrhizae Inoculation and Maggot Compost on Sunflower Development on Marginal Land
by: Obel Obel, et al.
Published: (2024-10-01) -
Adaptive treatment margins to reduce organs at risk dose in patients with no or minimal anatomical changes in radiotherapy of non-small cell lung cancer