ON THE DURABILITY OF PROGRESSIVE CAVITIES PUMPS

Within this project, it has been demonstrated that the progressive cavities pump flow rate varies depending on the position of the rotor in the stator. These variations, even if they take quite low values, are extremely important because they cause stator heating to record the highest temperature...

Full description

Saved in:
Bibliographic Details
Main Author: Marius STAN
Format: Article
Language:English
Published: Academica Brancusi 2018-05-01
Series:Fiabilitate şi Durabilitate
Subjects:
Online Access:http://www.utgjiu.ro/rev_mec/mecanica/pdf/2018-01/32_Marius%20STAN%20-%20ON%20THE%20DURABILITY%20OF%20PROGRESSIVE%20CAVITIES%20PUMPS.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Within this project, it has been demonstrated that the progressive cavities pump flow rate varies depending on the position of the rotor in the stator. These variations, even if they take quite low values, are extremely important because they cause stator heating to record the highest temperatures at 1/3 of the thickness of the elastomer and consequently to stiffen the pump or even damage the pump. Using the hydraulic controller technology, however, by changing its position according to the maximum volume recorded on the length of a stator step, it has been demonstrated that the flow can be uniformized by reducing the range of pulse propagation values