Calculation of Lead-Iron Double-Layer Thickness for Gamma-Ray Shielding by MATLAB Program
This contribution is aimed at designing the optimal thickness of lead-iron double-layer container to store a radioactive waste releasing the photon energy at 1.3325 MeV and initial radiation intensity at 100 mSv/hr using the optimization design by MATLAB software. This design consisted of three part...
Saved in:
Main Authors: | Sarai Lekchaum, Kitsakorn Locharoenrat |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2017-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2017/6078461 |