Subtrochanteric Fracture following Removal of a Porous Tantalum Implant
Osteonecrosis of the hip accounts for about 10% of all total hip arthroplasty cases and presents a significant challenge for those patients with and without femoral head collapse. Subtrochanteric femur fractures have been reported with numerous types of proximal femoral implants. Care must be taken...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Case Reports in Orthopedics |
Online Access: | http://dx.doi.org/10.1155/2013/946745 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Osteonecrosis of the hip accounts for about 10% of all total hip arthroplasty cases and presents a significant challenge for those patients with and without femoral head collapse. Subtrochanteric femur fractures have been reported with numerous types of proximal femoral implants. Care must be taken to avoid penetrating the lateral cortex of the proximal femur inferior to the distal border of the lesser trochanter. Core decompression requires a 3 mm to 20 mm defect in the lateral femoral cortex. Subtrochanteric femur fractures are a well-known complication of core decompression as well. We present a case of a subtrochanteric fracture following the removal of a porous tantalum implant. |
---|---|
ISSN: | 2090-6749 2090-6757 |