Fatigue behaviour of titanium dental endosseous implants
In this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during masticatio...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Gruppo Italiano Frattura
2011-10-01
|
Series: | Fracture and Structural Integrity |
Subjects: | |
Online Access: | http://www.gruppofrattura.it/pdf/rivista/numero18/numero_18_art_2.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832568733563879424 |
---|---|
author | Alessandro Scicutelli Daniela Pilone Ferdinando Felli |
author_facet | Alessandro Scicutelli Daniela Pilone Ferdinando Felli |
author_sort | Alessandro Scicutelli |
collection | DOAJ |
description | In this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during mastication motion. The results of these endurance tests are summarized in the form of Wohler-type diagrams showing the duration of a specific implant for different applied loads. These plots show a fatigue limit below which the implants could resist indefinitely. Other aspects of this research concern the influence of a potentially corrosive medium and the analysis of the deformation and failure of the specimens. During fatigue cycling, the titanium implants do not seem to be affected by a more aggressive environment, such as a saline solution. The analysis of the broken specimen allowed the crack initiation sites and the type of fracture propagation to be investigated in depth. In all the considered implants fatigue cracks were seen to initiate preferentially from sites in which the tensile stress concentration is the highest. The results of a finite element analysis performed on one of the specimens is in good agreement with the failure mode observed after the tests. The SEM fracture surface analysis shows a clear similarity between the fracture mode of the tested implants and of the actual implants broken after a certain operating period. |
format | Article |
id | doaj-art-ca797295c0ff41cb8c72464a85129413 |
institution | Kabale University |
issn | 1971-8993 |
language | English |
publishDate | 2011-10-01 |
publisher | Gruppo Italiano Frattura |
record_format | Article |
series | Fracture and Structural Integrity |
spelling | doaj-art-ca797295c0ff41cb8c72464a851294132025-02-03T00:42:25ZengGruppo Italiano FratturaFracture and Structural Integrity1971-89932011-10-015181422Fatigue behaviour of titanium dental endosseous implantsAlessandro ScicutelliDaniela PiloneFerdinando FelliIn this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during mastication motion. The results of these endurance tests are summarized in the form of Wohler-type diagrams showing the duration of a specific implant for different applied loads. These plots show a fatigue limit below which the implants could resist indefinitely. Other aspects of this research concern the influence of a potentially corrosive medium and the analysis of the deformation and failure of the specimens. During fatigue cycling, the titanium implants do not seem to be affected by a more aggressive environment, such as a saline solution. The analysis of the broken specimen allowed the crack initiation sites and the type of fracture propagation to be investigated in depth. In all the considered implants fatigue cracks were seen to initiate preferentially from sites in which the tensile stress concentration is the highest. The results of a finite element analysis performed on one of the specimens is in good agreement with the failure mode observed after the tests. The SEM fracture surface analysis shows a clear similarity between the fracture mode of the tested implants and of the actual implants broken after a certain operating period.http://www.gruppofrattura.it/pdf/rivista/numero18/numero_18_art_2.pdfDental implantsFatigue resistanceTitanium alloys |
spellingShingle | Alessandro Scicutelli Daniela Pilone Ferdinando Felli Fatigue behaviour of titanium dental endosseous implants Fracture and Structural Integrity Dental implants Fatigue resistance Titanium alloys |
title | Fatigue behaviour of titanium dental endosseous implants |
title_full | Fatigue behaviour of titanium dental endosseous implants |
title_fullStr | Fatigue behaviour of titanium dental endosseous implants |
title_full_unstemmed | Fatigue behaviour of titanium dental endosseous implants |
title_short | Fatigue behaviour of titanium dental endosseous implants |
title_sort | fatigue behaviour of titanium dental endosseous implants |
topic | Dental implants Fatigue resistance Titanium alloys |
url | http://www.gruppofrattura.it/pdf/rivista/numero18/numero_18_art_2.pdf |
work_keys_str_mv | AT alessandroscicutelli fatiguebehaviouroftitaniumdentalendosseousimplants AT danielapilone fatiguebehaviouroftitaniumdentalendosseousimplants AT ferdinandofelli fatiguebehaviouroftitaniumdentalendosseousimplants |