Fatigue behaviour of titanium dental endosseous implants

In this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during masticatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Alessandro Scicutelli, Daniela Pilone, Ferdinando Felli
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2011-10-01
Series:Fracture and Structural Integrity
Subjects:
Online Access:http://www.gruppofrattura.it/pdf/rivista/numero18/numero_18_art_2.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832568733563879424
author Alessandro Scicutelli
Daniela Pilone
Ferdinando Felli
author_facet Alessandro Scicutelli
Daniela Pilone
Ferdinando Felli
author_sort Alessandro Scicutelli
collection DOAJ
description In this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during mastication motion. The results of these endurance tests are summarized in the form of Wohler-type diagrams showing the duration of a specific implant for different applied loads. These plots show a fatigue limit below which the implants could resist indefinitely. Other aspects of this research concern the influence of a potentially corrosive medium and the analysis of the deformation and failure of the specimens. During fatigue cycling, the titanium implants do not seem to be affected by a more aggressive environment, such as a saline solution. The analysis of the broken specimen allowed the crack initiation sites and the type of fracture propagation to be investigated in depth. In all the considered implants fatigue cracks were seen to initiate preferentially from sites in which the tensile stress concentration is the highest. The results of a finite element analysis performed on one of the specimens is in good agreement with the failure mode observed after the tests. The SEM fracture surface analysis shows a clear similarity between the fracture mode of the tested implants and of the actual implants broken after a certain operating period.
format Article
id doaj-art-ca797295c0ff41cb8c72464a85129413
institution Kabale University
issn 1971-8993
language English
publishDate 2011-10-01
publisher Gruppo Italiano Frattura
record_format Article
series Fracture and Structural Integrity
spelling doaj-art-ca797295c0ff41cb8c72464a851294132025-02-03T00:42:25ZengGruppo Italiano FratturaFracture and Structural Integrity1971-89932011-10-015181422Fatigue behaviour of titanium dental endosseous implantsAlessandro ScicutelliDaniela PiloneFerdinando FelliIn this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during mastication motion. The results of these endurance tests are summarized in the form of Wohler-type diagrams showing the duration of a specific implant for different applied loads. These plots show a fatigue limit below which the implants could resist indefinitely. Other aspects of this research concern the influence of a potentially corrosive medium and the analysis of the deformation and failure of the specimens. During fatigue cycling, the titanium implants do not seem to be affected by a more aggressive environment, such as a saline solution. The analysis of the broken specimen allowed the crack initiation sites and the type of fracture propagation to be investigated in depth. In all the considered implants fatigue cracks were seen to initiate preferentially from sites in which the tensile stress concentration is the highest. The results of a finite element analysis performed on one of the specimens is in good agreement with the failure mode observed after the tests. The SEM fracture surface analysis shows a clear similarity between the fracture mode of the tested implants and of the actual implants broken after a certain operating period.http://www.gruppofrattura.it/pdf/rivista/numero18/numero_18_art_2.pdfDental implantsFatigue resistanceTitanium alloys
spellingShingle Alessandro Scicutelli
Daniela Pilone
Ferdinando Felli
Fatigue behaviour of titanium dental endosseous implants
Fracture and Structural Integrity
Dental implants
Fatigue resistance
Titanium alloys
title Fatigue behaviour of titanium dental endosseous implants
title_full Fatigue behaviour of titanium dental endosseous implants
title_fullStr Fatigue behaviour of titanium dental endosseous implants
title_full_unstemmed Fatigue behaviour of titanium dental endosseous implants
title_short Fatigue behaviour of titanium dental endosseous implants
title_sort fatigue behaviour of titanium dental endosseous implants
topic Dental implants
Fatigue resistance
Titanium alloys
url http://www.gruppofrattura.it/pdf/rivista/numero18/numero_18_art_2.pdf
work_keys_str_mv AT alessandroscicutelli fatiguebehaviouroftitaniumdentalendosseousimplants
AT danielapilone fatiguebehaviouroftitaniumdentalendosseousimplants
AT ferdinandofelli fatiguebehaviouroftitaniumdentalendosseousimplants