Metrological Guarantee of Flashing Light Measurements

The results of the modernization of the State primary standard unit of luminous intensity concerned with extension of functional capabilities in the area of the reproduction and transfer of flashing light quantities. Described reproduction and transfer procedures of the light units - illumination. F...

Full description

Saved in:
Bibliographic Details
Main Authors: P. Neyezhmakov, A. Kupko, V. Tereshchenko, G. Churyumov
Format: Article
Language:English
Published: Sumy State University 2017-02-01
Series:Журнал нано- та електронної фізики
Subjects:
Online Access:http://jnep.sumdu.edu.ua/download/numbers/2017/1/articles/jnep_V9_01013.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The results of the modernization of the State primary standard unit of luminous intensity concerned with extension of functional capabilities in the area of the reproduction and transfer of flashing light quantities. Described reproduction and transfer procedures of the light units - illumination. For the first time in Ukraine to transmit the flashing light quantities was used LED light sources. The basic changes in the project state verification scheme of the light measurements. The results of the development of calibration methods of the flickermeters and pulse photometers.
ISSN:2077-6772