Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access Memory

Abstract From the perspective of developing low‐power mobile healthcare devices capable of real‐time electrogram diagnosis, memristor‐based physical reservoir computing (PRC) offers a promising alternative to conventional deep neural network (DNN)‐based systems. Here, real‐time electrocardiogram (EC...

Full description

Saved in:
Bibliographic Details
Main Authors: Kyumin Lee, Dongmin Kim, Jongseon Seo, Hyunsang Hwang
Format: Article
Language:English
Published: Wiley-VCH 2025-07-01
Series:Advanced Electronic Materials
Subjects:
Online Access:https://doi.org/10.1002/aelm.202400920
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849719699469762560
author Kyumin Lee
Dongmin Kim
Jongseon Seo
Hyunsang Hwang
author_facet Kyumin Lee
Dongmin Kim
Jongseon Seo
Hyunsang Hwang
author_sort Kyumin Lee
collection DOAJ
description Abstract From the perspective of developing low‐power mobile healthcare devices capable of real‐time electrogram diagnosis, memristor‐based physical reservoir computing (PRC) offers a promising alternative to conventional deep neural network (DNN)‐based systems. Here, real‐time electrocardiogram (ECG) monitoring and arrhythmia detection are demonstrated using electrochemical random‐access memory (ECRAM)‐based PRC. ECRAM devices provide the millisecond‐range temporal resolution required for bio‐potential signals like ECG. Through material and process engineering, it is identified that higher ionic conductivity (σion) in the electrolyte layer and lower ionic diffusivity (Dion) in the channel layer are crucial for achieving non‐linear dynamics and fading memory characteristics. In addition, LaF3/WOx‐based ECRAM exhibits low‐power operation (≈300 pW spike−1) with minimal cycle‐to‐cycle (CTC) variation (<10%). Arrhythmia detection tests confirmed the feasibility of real‐time ECG monitoring, achieving a high classification accuracy of 93.04% with a 50‐fold reduction in training parameters compared to DNN‐based systems. Therefore, the developed LaF3/WOx‐based ECRAM with engineering guidelines of ion dynamics makes a significant contribution to mobile healthcare systems for electrogram diagnosis.
format Article
id doaj-art-c52e18c3c1144b18a1d76b412a9ccf93
institution DOAJ
issn 2199-160X
language English
publishDate 2025-07-01
publisher Wiley-VCH
record_format Article
series Advanced Electronic Materials
spelling doaj-art-c52e18c3c1144b18a1d76b412a9ccf932025-08-20T03:12:05ZengWiley-VCHAdvanced Electronic Materials2199-160X2025-07-011111n/an/a10.1002/aelm.202400920Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access MemoryKyumin Lee0Dongmin Kim1Jongseon Seo2Hyunsang Hwang3Center for Single Atom‐based Semiconductor Device and the Department of Materials Science and Engineering Pohang University of Science and Technology Pohang 37673 Republic of KoreaCenter for Single Atom‐based Semiconductor Device and the Department of Materials Science and Engineering Pohang University of Science and Technology Pohang 37673 Republic of KoreaCenter for Single Atom‐based Semiconductor Device and the Department of Materials Science and Engineering Pohang University of Science and Technology Pohang 37673 Republic of KoreaCenter for Single Atom‐based Semiconductor Device and the Department of Materials Science and Engineering Pohang University of Science and Technology Pohang 37673 Republic of KoreaAbstract From the perspective of developing low‐power mobile healthcare devices capable of real‐time electrogram diagnosis, memristor‐based physical reservoir computing (PRC) offers a promising alternative to conventional deep neural network (DNN)‐based systems. Here, real‐time electrocardiogram (ECG) monitoring and arrhythmia detection are demonstrated using electrochemical random‐access memory (ECRAM)‐based PRC. ECRAM devices provide the millisecond‐range temporal resolution required for bio‐potential signals like ECG. Through material and process engineering, it is identified that higher ionic conductivity (σion) in the electrolyte layer and lower ionic diffusivity (Dion) in the channel layer are crucial for achieving non‐linear dynamics and fading memory characteristics. In addition, LaF3/WOx‐based ECRAM exhibits low‐power operation (≈300 pW spike−1) with minimal cycle‐to‐cycle (CTC) variation (<10%). Arrhythmia detection tests confirmed the feasibility of real‐time ECG monitoring, achieving a high classification accuracy of 93.04% with a 50‐fold reduction in training parameters compared to DNN‐based systems. Therefore, the developed LaF3/WOx‐based ECRAM with engineering guidelines of ion dynamics makes a significant contribution to mobile healthcare systems for electrogram diagnosis.https://doi.org/10.1002/aelm.202400920electrocardiogram arrhythmia detectionelectrochemical random‐access memoryionic conductivityionic diffusivitynon‐linear dynamicsphysical reservoir computing
spellingShingle Kyumin Lee
Dongmin Kim
Jongseon Seo
Hyunsang Hwang
Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access Memory
Advanced Electronic Materials
electrocardiogram arrhythmia detection
electrochemical random‐access memory
ionic conductivity
ionic diffusivity
non‐linear dynamics
physical reservoir computing
title Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access Memory
title_full Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access Memory
title_fullStr Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access Memory
title_full_unstemmed Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access Memory
title_short Physical Reservoir Computing for Real‐Time Electrocardiogram Arrhythmia Detection Through Controlled Ion Dynamics in Electrochemical Random‐Access Memory
title_sort physical reservoir computing for real time electrocardiogram arrhythmia detection through controlled ion dynamics in electrochemical random access memory
topic electrocardiogram arrhythmia detection
electrochemical random‐access memory
ionic conductivity
ionic diffusivity
non‐linear dynamics
physical reservoir computing
url https://doi.org/10.1002/aelm.202400920
work_keys_str_mv AT kyuminlee physicalreservoircomputingforrealtimeelectrocardiogramarrhythmiadetectionthroughcontrollediondynamicsinelectrochemicalrandomaccessmemory
AT dongminkim physicalreservoircomputingforrealtimeelectrocardiogramarrhythmiadetectionthroughcontrollediondynamicsinelectrochemicalrandomaccessmemory
AT jongseonseo physicalreservoircomputingforrealtimeelectrocardiogramarrhythmiadetectionthroughcontrollediondynamicsinelectrochemicalrandomaccessmemory
AT hyunsanghwang physicalreservoircomputingforrealtimeelectrocardiogramarrhythmiadetectionthroughcontrollediondynamicsinelectrochemicalrandomaccessmemory