Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes

THE PURPOSE. Consider the most pressing and important problems of parallel operation of generator sets as part of autonomous electrical complexes of modern sea vessels, such as the transition of diesel generator sets to reverse power mode and the existence of power exchange oscillations during paral...

Full description

Saved in:
Bibliographic Details
Main Authors: A. E. Savenko, P. S. Kerch
Format: Article
Language:English
Published: Kazan State Power Engineering University 2021-05-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1771
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850147846276251648
author A. E. Savenko
P. S. Kerch
author_facet A. E. Savenko
P. S. Kerch
author_sort A. E. Savenko
collection DOAJ
description THE PURPOSE. Consider the most pressing and important problems of parallel operation of generator sets as part of autonomous electrical complexes of modern sea vessels, such as the transition of diesel generator sets to reverse power mode and the existence of power exchange oscillations during parallel operation. Consider the possibility of improving the method for eliminating power exchange oscillations using maps of dependences of the amplitude of oscillations on the parameters of diesel generator sets. METHODS. When solving the problem, a mathematical model of an autonomous electrical complex was used, which allows to take into account the backlash clearances in the control loops of the rotation frequency of parallel diesel generator sets. RESULTS. A map of the dependence of the load angle on the backlash clearances was constructed. The complete identity of the maps of the dependence of the load angle on the backlash clearances and the maps of the dependence of the amplitude of the power exchange oscillations on the backlash gaps has been proved. In the criterion for determining the value of the amplitude of the power exchange oscillations, it is proposed to use the load angle of the generators instead of the envelope currents of the generators. CONCLUSION. The use of the load angle of parallel operating generators allows to increase the speed and accuracy of the unit for eliminating power exchange oscillations. The developed approach makes it possible to control the transition of generating sets to the reverse power mode and the appearance of power exchange oscillations based on measuring the load angles of the generators.
format Article
id doaj-art-c45ede371d514ee78edf596c8962111e
institution OA Journals
issn 1998-9903
language English
publishDate 2021-05-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-c45ede371d514ee78edf596c8962111e2025-08-20T02:27:27ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032021-05-0123119720710.30724/1998-9903-2021-23-1-197-207738Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexesA. E. Savenko0P. S. Kerch1Kerch State Maritime Technological UniversityKerch State Maritime Technological UniversityTHE PURPOSE. Consider the most pressing and important problems of parallel operation of generator sets as part of autonomous electrical complexes of modern sea vessels, such as the transition of diesel generator sets to reverse power mode and the existence of power exchange oscillations during parallel operation. Consider the possibility of improving the method for eliminating power exchange oscillations using maps of dependences of the amplitude of oscillations on the parameters of diesel generator sets. METHODS. When solving the problem, a mathematical model of an autonomous electrical complex was used, which allows to take into account the backlash clearances in the control loops of the rotation frequency of parallel diesel generator sets. RESULTS. A map of the dependence of the load angle on the backlash clearances was constructed. The complete identity of the maps of the dependence of the load angle on the backlash clearances and the maps of the dependence of the amplitude of the power exchange oscillations on the backlash gaps has been proved. In the criterion for determining the value of the amplitude of the power exchange oscillations, it is proposed to use the load angle of the generators instead of the envelope currents of the generators. CONCLUSION. The use of the load angle of parallel operating generators allows to increase the speed and accuracy of the unit for eliminating power exchange oscillations. The developed approach makes it possible to control the transition of generating sets to the reverse power mode and the appearance of power exchange oscillations based on measuring the load angles of the generators.https://www.energyret.ru/jour/article/view/1771power exchange oscillationsparallel operationautonomous electric power complexload anglegenerating setexperimental research
spellingShingle A. E. Savenko
P. S. Kerch
Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes
Известия высших учебных заведений: Проблемы энергетики
power exchange oscillations
parallel operation
autonomous electric power complex
load angle
generating set
experimental research
title Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes
title_full Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes
title_fullStr Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes
title_full_unstemmed Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes
title_short Use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes
title_sort use of load angle of synchronous generators to eliminate power exchange oscillations in autonomous electrical complexes
topic power exchange oscillations
parallel operation
autonomous electric power complex
load angle
generating set
experimental research
url https://www.energyret.ru/jour/article/view/1771
work_keys_str_mv AT aesavenko useofloadangleofsynchronousgeneratorstoeliminatepowerexchangeoscillationsinautonomouselectricalcomplexes
AT pskerch useofloadangleofsynchronousgeneratorstoeliminatepowerexchangeoscillationsinautonomouselectricalcomplexes