A Case of Implant Failure in Partial Wrist Fusion Applying Magnesium-Based Headless Bone Screws

This article presents a case of implant failure resulting in mechanical instability of a scaphotrapezotrapezoideal arthrodesis using magnesium-based headless bone screws. During revision surgery osteolysis surrounding the screws was observed as well as degraded screw threads already in existence at...

Full description

Saved in:
Bibliographic Details
Main Authors: Alice Wichelhaus, Judith Emmerich, Thomas Mittlmeier
Format: Article
Language:English
Published: Wiley 2016-01-01
Series:Case Reports in Orthopedics
Online Access:http://dx.doi.org/10.1155/2016/7049130
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This article presents a case of implant failure resulting in mechanical instability of a scaphotrapezotrapezoideal arthrodesis using magnesium-based headless bone screws. During revision surgery osteolysis surrounding the screws was observed as well as degraded screw threads already in existence at 6 weeks after implantation. The supposed osseous integration attributed to magnesium-based screws could not be reproduced in this particular case. Thus, it can be reasoned that the use of magnesium-based screws for partial wrist arthrodesis cannot be encouraged, at least not in dual use.
ISSN:2090-6749
2090-6757