The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltage
With the help of the methodological base of the study (the foundations of probability theory and mathematical statistics), the processing of the experiment conducted at the research object is carried out. This object is the mechanical workshop of CJSC Sibgazstroydetal, which is engaged in providi...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2024-06-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2024/%E2%84%962%20(190)%20%D0%9E%D0%9D%D0%92/77-86%20%D0%A0%D1%83%D0%B4%D0%B8%20%D0%94.%20%D0%AE.,%20%D0%90%D0%BD%D1%82%D0%BE%D0%BD%D0%BE%D0%B2%20%D0%90.%20%D0%98.,%20%D0%A0%D1%83%D0%BF%D0%BF%D0%B5%D0%BB%D1%8C%20%D0%90.%20%D0%90.,%20%20%D0%A0%D1%83%D0%BF%D0%BF%D0%B5%D0%BB%D1%8C%20%D0%95.%20%D0%AE.,%20%D0%A8%D0%B8%D1%82%D0%B8%D0%BA%20%D0%A2.%20%D0%92..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832557436712517632 |
---|---|
author | D. Yu. Rudi A. I. Antonov A. A. Ruppel E. Yu. Ruppel T. V. Shitik |
author_facet | D. Yu. Rudi A. I. Antonov A. A. Ruppel E. Yu. Ruppel T. V. Shitik |
author_sort | D. Yu. Rudi |
collection | DOAJ |
description | With the help of the methodological base of the study (the foundations of
probability theory and mathematical statistics), the processing of the experiment
conducted at the research object is carried out. This object is the mechanical
workshop of CJSC Sibgazstroydetal, which is engaged in providing for the needs
of the gas, oil and energy industries. In this paper, the issue of determining the
conductive low-frequency electromagnetic interference (EMI) by the coefficient of
the n-th harmonic component of the voltage (K U(n)
) is studied in detail. Harmonic
distortion is a constant phenomenon in electrical networks. Higher harmonics have a
negative impact on the electrical network, including on electric consumers (reduced
service life, productivity, etc.). The problem of non-sinusoidal voltages has been
studied for quite a long time and the results obtained during these studies confirm
the presence of a large number of damages to electricity consumers who are in
operation. The probability of occurrence of conductive low-frequency EMF by K U(n)
at the research site is determined. The paper analyzes the results obtained with
the help of the conducted research. According to the results of the analysis, the
relevant conclusions are presented. |
format | Article |
id | doaj-art-bd4de90945bc45a8884be012b6e87cbd |
institution | Kabale University |
issn | 1813-8225 2541-7541 |
language | English |
publishDate | 2024-06-01 |
publisher | Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education |
record_format | Article |
series | Омский научный вестник |
spelling | doaj-art-bd4de90945bc45a8884be012b6e87cbd2025-02-03T04:50:34ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412024-06-012 (190)778610.25206/1813-8225-2024-190-77-86The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltageD. Yu. Rudi0A. I. Antonov1A. A. Ruppel2E. Yu. Ruppel3T. V. Shitik4Omsk Institute of Water Transport (branch) Siberian State University Water TransportOmsk Institute of Water Transport (branch) Siberian State University Water TransportOmsk Institute of Water Transport (branch) Siberian State University Water TransportSiberian State Automobile and Highway UniversityOmsk River Command School named after Captain V. I. Evdokimov Omsk Institute of Water Transport (branch) Siberian State University Water TransportWith the help of the methodological base of the study (the foundations of probability theory and mathematical statistics), the processing of the experiment conducted at the research object is carried out. This object is the mechanical workshop of CJSC Sibgazstroydetal, which is engaged in providing for the needs of the gas, oil and energy industries. In this paper, the issue of determining the conductive low-frequency electromagnetic interference (EMI) by the coefficient of the n-th harmonic component of the voltage (K U(n) ) is studied in detail. Harmonic distortion is a constant phenomenon in electrical networks. Higher harmonics have a negative impact on the electrical network, including on electric consumers (reduced service life, productivity, etc.). The problem of non-sinusoidal voltages has been studied for quite a long time and the results obtained during these studies confirm the presence of a large number of damages to electricity consumers who are in operation. The probability of occurrence of conductive low-frequency EMF by K U(n) at the research site is determined. The paper analyzes the results obtained with the help of the conducted research. According to the results of the analysis, the relevant conclusions are presented.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2024/%E2%84%962%20(190)%20%D0%9E%D0%9D%D0%92/77-86%20%D0%A0%D1%83%D0%B4%D0%B8%20%D0%94.%20%D0%AE.,%20%D0%90%D0%BD%D1%82%D0%BE%D0%BD%D0%BE%D0%B2%20%D0%90.%20%D0%98.,%20%D0%A0%D1%83%D0%BF%D0%BF%D0%B5%D0%BB%D1%8C%20%D0%90.%20%D0%90.,%20%20%D0%A0%D1%83%D0%BF%D0%BF%D0%B5%D0%BB%D1%8C%20%D0%95.%20%D0%AE.,%20%D0%A8%D0%B8%D1%82%D0%B8%D0%BA%20%D0%A2.%20%D0%92..pdfquality of electric energyhigher harmonicsconductive interferencemathematical statistics and probability theorythe coefficient of the n-th harmonic component of stress |
spellingShingle | D. Yu. Rudi A. I. Antonov A. A. Ruppel E. Yu. Ruppel T. V. Shitik The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltage Омский научный вестник quality of electric energy higher harmonics conductive interference mathematical statistics and probability theory the coefficient of the n-th harmonic component of stress |
title | The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltage |
title_full | The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltage |
title_fullStr | The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltage |
title_full_unstemmed | The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltage |
title_short | The use of the methodological base of the study to determine the conduction of low-frequency electromagnetic interference according to the coefficient of the n-th harmonic component of the voltage |
title_sort | use of the methodological base of the study to determine the conduction of low frequency electromagnetic interference according to the coefficient of the n th harmonic component of the voltage |
topic | quality of electric energy higher harmonics conductive interference mathematical statistics and probability theory the coefficient of the n-th harmonic component of stress |
url | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2024/%E2%84%962%20(190)%20%D0%9E%D0%9D%D0%92/77-86%20%D0%A0%D1%83%D0%B4%D0%B8%20%D0%94.%20%D0%AE.,%20%D0%90%D0%BD%D1%82%D0%BE%D0%BD%D0%BE%D0%B2%20%D0%90.%20%D0%98.,%20%D0%A0%D1%83%D0%BF%D0%BF%D0%B5%D0%BB%D1%8C%20%D0%90.%20%D0%90.,%20%20%D0%A0%D1%83%D0%BF%D0%BF%D0%B5%D0%BB%D1%8C%20%D0%95.%20%D0%AE.,%20%D0%A8%D0%B8%D1%82%D0%B8%D0%BA%20%D0%A2.%20%D0%92..pdf |
work_keys_str_mv | AT dyurudi theuseofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT aiantonov theuseofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT aaruppel theuseofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT eyuruppel theuseofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT tvshitik theuseofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT dyurudi useofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT aiantonov useofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT aaruppel useofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT eyuruppel useofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage AT tvshitik useofthemethodologicalbaseofthestudytodeterminetheconductionoflowfrequencyelectromagneticinterferenceaccordingtothecoefficientofthenthharmoniccomponentofthevoltage |