Estimation of Heavy Metals in Multivitamin Tablets by Differential Pulse Anodic Stripping Voltammetry

Differential pulse anodic stripping voltammetry (DPASV) was applied for the simultaneous determination of zinc and copper in multivitamin tablet (supradyn and centrum). Determination of the metals was made in ammonium acetate buffer (pH 4.5) with a scan rate of 0.01 V/s by Hanging Mercury Dropping E...

Full description

Saved in:
Bibliographic Details
Main Authors: Kumar Rohit Raj, Shashank Sharma, Sachin Saxena, M. M. Srivastava, Soami P. Satsangi
Format: Article
Language:English
Published: Wiley 2010-01-01
Series:E-Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2010/152416
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Differential pulse anodic stripping voltammetry (DPASV) was applied for the simultaneous determination of zinc and copper in multivitamin tablet (supradyn and centrum). Determination of the metals was made in ammonium acetate buffer (pH 4.5) with a scan rate of 0.01 V/s by Hanging Mercury Dropping Electrode (HMDE).The solution was stirred during electrolysis at -1.3 V for 300 s in the potential range of -1.3 to + 0.1 V. Concentrations of zinc and copper in supradyn drug sample were found to be 1.80 and 2.9 mg/tablet and for centrum drug sample were found to be 4.6 and 0.94 mg/tablet respectively.
ISSN:0973-4945
2090-9810