Determining correct tracheal tube insertion depth by measuring distance between endotracheal tube cuff and vocal cords by ultrasound in Chinese adults: a prospective case-control study
Objectives Unrecognised malposition of the endotracheal tube can lead to severe complications in patients under general anaesthesia. The purpose of this study was to verify the feasibility of using ultrasound to measure the distance between the upper edge of saline-inflated cuff and the vocal cords....
Saved in:
Main Authors: | Xuanling Chen, Wenwen Zhai, Zhuoying Yu, Jiao Geng, Min Li |
---|---|
Format: | Article |
Language: | English |
Published: |
BMJ Publishing Group
2018-12-01
|
Series: | BMJ Open |
Online Access: | https://bmjopen.bmj.com/content/8/12/e023374.full |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Endotracheal tube cuff pressure assessment: expectations versus reality
by: Valentyn Sadovyi, et al.
Published: (2024-11-01) -
Cuff Failure of Spiral-Filled Polyvinyl Chloride Endotracheal Tube Immediately after Tracheal Intubation Using a Channeled Videolaryngoscope (Pentax Airway Scope)
by: Koichi Nishikawa, et al.
Published: (2020-01-01) -
The Relationship between Cuff Pressure and Air Injection Volume of Endotracheal Tube: A Study with Sheep Trachea Ex Vivo
by: Ruixue Wang, et al.
Published: (2022-01-01) -
Tracheal perforation and subcutaneous emphysema secondary to pseudomembranous invasive Aspergillus tracheobronchitis successfully managed with endotracheal tube manipulation
by: Kazushige Shiraishi, et al.
Published: (2025-01-01) -
Achieving the Recommended Endotracheal Tube Cuff Pressure: A Randomized Control Study Comparing Loss of Resistance Syringe to Pilot Balloon Palpation
by: Fred Bulamba, et al.
Published: (2017-01-01)