Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices

Oral implantology faces a multitude of technical challenges in light of current clinical experience, underlining the need for innovation in implantable medical devices in both mechanical and biological terms. <b>Objectives:</b> This study explores the influence of the thickness factor of...

Full description

Saved in:
Bibliographic Details
Main Authors: Alex Tchinda, Richard Kouitat-Ndjiwa, Pierre Bravetti
Format: Article
Language:English
Published: MDPI AG 2024-12-01
Series:Biomedicines
Subjects:
Online Access:https://www.mdpi.com/2227-9059/13/1/37
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832589071244853248
author Alex Tchinda
Richard Kouitat-Ndjiwa
Pierre Bravetti
author_facet Alex Tchinda
Richard Kouitat-Ndjiwa
Pierre Bravetti
author_sort Alex Tchinda
collection DOAJ
description Oral implantology faces a multitude of technical challenges in light of current clinical experience, underlining the need for innovation in implantable medical devices in both mechanical and biological terms. <b>Objectives:</b> This study explores the influence of the thickness factor of calcium-doped zirconia (Ca-SZ) coatings deposited by PVD on their intrinsic mechanical properties and the determinism of the latter on adhesion to the TA6V alloy substrate after mechanical loading for applications in dental implantology. <b>Methods:</b> Three separate thicknesses of 250 nm, 450 nm and 850 nm were evaluated in terms of mechanical strength, modulus of elasticity and adhesion to the substrate, in accordance with ISO 20502:2005. <b>Results</b>: The results show an increase in apparent modulus of elasticity with thickness, reaching values of around 25.05 GPa and 36.3 GPa, close to the cortical bone for the 250 nm and 450 nm thick coatings, respectively. Adhesion tests show a progressive improvement up to 450 nm, followed by a similar observation at 850 nm, underlining the importance of optimal thickness to balance mechanical protection and biomechanical compatibility. Furthermore, the initial roughness and topography of the substrate were not influenced by the different thicknesses of the Ca-SZ coating. <b>Conclusions:</b> Together, these results reinforce the potential of Ca-SZ coatings to minimise stress shielding in dental implants.
format Article
id doaj-art-b8e260b054624187bba6566c812ccd40
institution Kabale University
issn 2227-9059
language English
publishDate 2024-12-01
publisher MDPI AG
record_format Article
series Biomedicines
spelling doaj-art-b8e260b054624187bba6566c812ccd402025-01-24T13:23:48ZengMDPI AGBiomedicines2227-90592024-12-011313710.3390/biomedicines13010037Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical DevicesAlex Tchinda0Richard Kouitat-Ndjiwa1Pierre Bravetti2Jean Lamour Institute, Department of Micro and Nanomechanics for Life, University of Lorraine, UMR 7198, 54011 Nancy, FranceJean Lamour Institute, Department of Micro and Nanomechanics for Life, University of Lorraine, UMR 7198, 54011 Nancy, FranceJean Lamour Institute, Department of Micro and Nanomechanics for Life, University of Lorraine, UMR 7198, 54011 Nancy, FranceOral implantology faces a multitude of technical challenges in light of current clinical experience, underlining the need for innovation in implantable medical devices in both mechanical and biological terms. <b>Objectives:</b> This study explores the influence of the thickness factor of calcium-doped zirconia (Ca-SZ) coatings deposited by PVD on their intrinsic mechanical properties and the determinism of the latter on adhesion to the TA6V alloy substrate after mechanical loading for applications in dental implantology. <b>Methods:</b> Three separate thicknesses of 250 nm, 450 nm and 850 nm were evaluated in terms of mechanical strength, modulus of elasticity and adhesion to the substrate, in accordance with ISO 20502:2005. <b>Results</b>: The results show an increase in apparent modulus of elasticity with thickness, reaching values of around 25.05 GPa and 36.3 GPa, close to the cortical bone for the 250 nm and 450 nm thick coatings, respectively. Adhesion tests show a progressive improvement up to 450 nm, followed by a similar observation at 850 nm, underlining the importance of optimal thickness to balance mechanical protection and biomechanical compatibility. Furthermore, the initial roughness and topography of the substrate were not influenced by the different thicknesses of the Ca-SZ coating. <b>Conclusions:</b> Together, these results reinforce the potential of Ca-SZ coatings to minimise stress shielding in dental implants.https://www.mdpi.com/2227-9059/13/1/37coatingCa-SZadhesionbiomechanicsYoung’s modulus
spellingShingle Alex Tchinda
Richard Kouitat-Ndjiwa
Pierre Bravetti
Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices
Biomedicines
coating
Ca-SZ
adhesion
biomechanics
Young’s modulus
title Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices
title_full Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices
title_fullStr Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices
title_full_unstemmed Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices
title_short Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices
title_sort multi scale characterisation and mechanical adhesion in pvd deposited ca sz coating for implantable medical devices
topic coating
Ca-SZ
adhesion
biomechanics
Young’s modulus
url https://www.mdpi.com/2227-9059/13/1/37
work_keys_str_mv AT alextchinda multiscalecharacterisationandmechanicaladhesioninpvddepositedcaszcoatingforimplantablemedicaldevices
AT richardkouitatndjiwa multiscalecharacterisationandmechanicaladhesioninpvddepositedcaszcoatingforimplantablemedicaldevices
AT pierrebravetti multiscalecharacterisationandmechanicaladhesioninpvddepositedcaszcoatingforimplantablemedicaldevices