While starting turbines from cold and non-cooled-down states rotors are heated quicker than cylinders due to significantly less weight and more intensive interaction with steam and the value of their differential expansion reaches up to the rated ones in the period of 4-5 hours.The investigations ha...

Full description

Saved in:
Bibliographic Details
Main Authors: V. P. Kashcheev, E. O. Vоrоnоv, V. A. Khаimоv, A. V. Kashcheev, V. N. Sоrоkin
Format: Article
Language:Russian
Published: Belarusian National Technical University 2011-04-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Online Access:https://energy.bntu.by/jour/article/view/298
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:While starting turbines from cold and non-cooled-down states rotors are heated quicker than cylinders due to significantly less weight and more intensive interaction with steam and the value of their differential expansion reaches up to the rated ones in the period of 4-5 hours.The investigations have revealed that while using a swirling steam attemperator it is possible to feed steam to turbine seals of the required temperature and at the required time during its variable operational conditions. This methodology makes it possible to save 400 t of specific fuel. In addition to this operational reliability of a power block is increased and a number and cost of repairs is decreased.