ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA)
It is necessary to analyze the structural strength of the square chamber component in the design of injection multicasting pyrogenic igniter to ensure that the structural components of the chamber are able to withstand loads from hydraulic piston pressure. Four square chamber configurations were ana...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Brawijaya
2024-12-01
|
Series: | Rekayasa Mesin |
Subjects: | |
Online Access: | https://rekayasamesin.ub.ac.id/index.php/rm/article/view/1726 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832592885176860672 |
---|---|
author | Rama Dwi Prayoga Ichsan Dwi Prasetyo Maharani Inas Mahdiyyah |
author_facet | Rama Dwi Prayoga Ichsan Dwi Prasetyo Maharani Inas Mahdiyyah |
author_sort | Rama Dwi Prayoga |
collection | DOAJ |
description | It is necessary to analyze the structural strength of the square chamber component in the design of injection multicasting pyrogenic igniter to ensure that the structural components of the chamber are able to withstand loads from hydraulic piston pressure. Four square chamber configurations were analyzed using the Autodesk Inventor software FEA method. Load simulations are given at 10,000 N, 50,000 N, and 100,000 N. Von Mises stress, safety factor, and displacement are obtained for each design configuration. Where it is known that the structural design of the square chamber design configurations 1, 2, and 3 has optimal reliability at a load capacity of up to ± 10,000 N. As for the structural design of the square chamber design configuration 4, it is known to have optimal reliability at a load capacity of 50,000 N. However it is possible that it is reliable enough to withstand load capacities up to ± 100,000 N. |
format | Article |
id | doaj-art-b78db6e77b5f4282aee281a0a1549db5 |
institution | Kabale University |
issn | 2338-1663 2477-6041 |
language | English |
publishDate | 2024-12-01 |
publisher | University of Brawijaya |
record_format | Article |
series | Rekayasa Mesin |
spelling | doaj-art-b78db6e77b5f4282aee281a0a1549db52025-01-21T01:57:48ZengUniversity of BrawijayaRekayasa Mesin2338-16632477-60412024-12-011531483149210.21776/jrm.v15i3.17261437ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA)Rama Dwi Prayoga0Ichsan Dwi PrasetyoMaharani Inas MahdiyyahBRINIt is necessary to analyze the structural strength of the square chamber component in the design of injection multicasting pyrogenic igniter to ensure that the structural components of the chamber are able to withstand loads from hydraulic piston pressure. Four square chamber configurations were analyzed using the Autodesk Inventor software FEA method. Load simulations are given at 10,000 N, 50,000 N, and 100,000 N. Von Mises stress, safety factor, and displacement are obtained for each design configuration. Where it is known that the structural design of the square chamber design configurations 1, 2, and 3 has optimal reliability at a load capacity of up to ± 10,000 N. As for the structural design of the square chamber design configuration 4, it is known to have optimal reliability at a load capacity of 50,000 N. However it is possible that it is reliable enough to withstand load capacities up to ± 100,000 N.https://rekayasamesin.ub.ac.id/index.php/rm/article/view/1726feainjection moldingstrength analysisvon miseshydraulic piston pressure |
spellingShingle | Rama Dwi Prayoga Ichsan Dwi Prasetyo Maharani Inas Mahdiyyah ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA) Rekayasa Mesin fea injection molding strength analysis von mises hydraulic piston pressure |
title | ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA) |
title_full | ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA) |
title_fullStr | ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA) |
title_full_unstemmed | ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA) |
title_short | ANALISIS KEKUATAN STRUKTUR SQUARE CHAMBER INJECTION MULTICASTING PYROGENIC IGNITER MENGGUNAKAN FINITE ELEMENT ANALYSIS (FEA) |
title_sort | analisis kekuatan struktur square chamber injection multicasting pyrogenic igniter menggunakan finite element analysis fea |
topic | fea injection molding strength analysis von mises hydraulic piston pressure |
url | https://rekayasamesin.ub.ac.id/index.php/rm/article/view/1726 |
work_keys_str_mv | AT ramadwiprayoga analisiskekuatanstruktursquarechamberinjectionmulticastingpyrogenicignitermenggunakanfiniteelementanalysisfea AT ichsandwiprasetyo analisiskekuatanstruktursquarechamberinjectionmulticastingpyrogenicignitermenggunakanfiniteelementanalysisfea AT maharaniinasmahdiyyah analisiskekuatanstruktursquarechamberinjectionmulticastingpyrogenicignitermenggunakanfiniteelementanalysisfea |