Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates
In recent years, recycled aggregates from construction and demolition waste (CDW) have been widely accepted in construction sectors as the replacement of coarse aggregate in order to minimize the excessive use of natural resources. In this paper, an experimental investigation is carried out to obser...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2017-01-01
|
Series: | Advances in Civil Engineering |
Online Access: | http://dx.doi.org/10.1155/2017/1812363 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832545392955228160 |
---|---|
author | Md. Shariful Islam Mohammad Al Amin Siddique |
author_facet | Md. Shariful Islam Mohammad Al Amin Siddique |
author_sort | Md. Shariful Islam |
collection | DOAJ |
description | In recent years, recycled aggregates from construction and demolition waste (CDW) have been widely accepted in construction sectors as the replacement of coarse aggregate in order to minimize the excessive use of natural resources. In this paper, an experimental investigation is carried out to observe the influence of low grade steel fiber reinforcements on the stress-strain behavior of concrete made with recycled and fresh brick aggregates. In addition, compressive strength by destructive and nondestructive tests, splitting tensile strength, and Young’s modulus are determined. Hooked end steel wires with 50 mm of length and an aspect ratio of 55.6 are used as fiber reinforcements in a volume fraction of 0% (control case), 0.50%, and 1.00% in concrete mixes. The same gradation of aggregates and water-cement ratio (w/c=0.44) were used to assess the effect of steel fiber in all these concrete mixes. All tests were conducted at 7, 14, and 28 days to perceive the effect of age on different mechanical properties. The experimental results show that around 10%~15% and 40%~60% increase in 28 days compressive strength and tensile strength of steel fiber reinforced concrete, respectively, compared to those of the control case. It is observed that the effect of addition of 1% fiber on the concrete compressive strength is little compared to that of 0.5% steel fiber addition. On the other hand, strain of concrete at failure of steel fiber reinforced concrete has increased almost twice compared to the control case. A simple analytical model is also proposed to generate the ascending portions of the stress-strain curve of concrete. There exists a good correlation between the experimental results and the analytical model. A relatively ductile failure is observed for the concrete made with low grade steel fibers. |
format | Article |
id | doaj-art-b2f249e973af443080b8d6c70fbe24ea |
institution | Kabale University |
issn | 1687-8086 1687-8094 |
language | English |
publishDate | 2017-01-01 |
publisher | Wiley |
record_format | Article |
series | Advances in Civil Engineering |
spelling | doaj-art-b2f249e973af443080b8d6c70fbe24ea2025-02-03T07:25:57ZengWileyAdvances in Civil Engineering1687-80861687-80942017-01-01201710.1155/2017/18123631812363Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick AggregatesMd. Shariful Islam0Mohammad Al Amin Siddique1Department of Civil Engineering, World University of Bangladesh, Dhaka 1205, BangladeshDepartment of Civil Engineering, Bangladesh University of Engineering and Technology, Dhaka 1000, BangladeshIn recent years, recycled aggregates from construction and demolition waste (CDW) have been widely accepted in construction sectors as the replacement of coarse aggregate in order to minimize the excessive use of natural resources. In this paper, an experimental investigation is carried out to observe the influence of low grade steel fiber reinforcements on the stress-strain behavior of concrete made with recycled and fresh brick aggregates. In addition, compressive strength by destructive and nondestructive tests, splitting tensile strength, and Young’s modulus are determined. Hooked end steel wires with 50 mm of length and an aspect ratio of 55.6 are used as fiber reinforcements in a volume fraction of 0% (control case), 0.50%, and 1.00% in concrete mixes. The same gradation of aggregates and water-cement ratio (w/c=0.44) were used to assess the effect of steel fiber in all these concrete mixes. All tests were conducted at 7, 14, and 28 days to perceive the effect of age on different mechanical properties. The experimental results show that around 10%~15% and 40%~60% increase in 28 days compressive strength and tensile strength of steel fiber reinforced concrete, respectively, compared to those of the control case. It is observed that the effect of addition of 1% fiber on the concrete compressive strength is little compared to that of 0.5% steel fiber addition. On the other hand, strain of concrete at failure of steel fiber reinforced concrete has increased almost twice compared to the control case. A simple analytical model is also proposed to generate the ascending portions of the stress-strain curve of concrete. There exists a good correlation between the experimental results and the analytical model. A relatively ductile failure is observed for the concrete made with low grade steel fibers.http://dx.doi.org/10.1155/2017/1812363 |
spellingShingle | Md. Shariful Islam Mohammad Al Amin Siddique Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates Advances in Civil Engineering |
title | Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates |
title_full | Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates |
title_fullStr | Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates |
title_full_unstemmed | Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates |
title_short | Behavior of Low Grade Steel Fiber Reinforced Concrete Made with Fresh and Recycled Brick Aggregates |
title_sort | behavior of low grade steel fiber reinforced concrete made with fresh and recycled brick aggregates |
url | http://dx.doi.org/10.1155/2017/1812363 |
work_keys_str_mv | AT mdsharifulislam behavioroflowgradesteelfiberreinforcedconcretemadewithfreshandrecycledbrickaggregates AT mohammadalaminsiddique behavioroflowgradesteelfiberreinforcedconcretemadewithfreshandrecycledbrickaggregates |