Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane Electrode
A novel chromate selective PVC membrane electrode was constructed using a hexadecyltrimethylammonium-surfactant modified zeolite (SMZ). Nano particles of an Iranian clinoptilolite zeolite were prepared by a ball-mill mechanical method and characterized by FT-IR, SEM and XRD. Best performance was exh...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | Journal of Chemistry |
Online Access: | http://dx.doi.org/10.1155/2013/685290 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832553081324175360 |
---|---|
author | Alireza Nezamzadeh-Ejhieh Gholamhosein Raja |
author_facet | Alireza Nezamzadeh-Ejhieh Gholamhosein Raja |
author_sort | Alireza Nezamzadeh-Ejhieh |
collection | DOAJ |
description | A novel chromate selective PVC membrane electrode was constructed using a hexadecyltrimethylammonium-surfactant modified zeolite (SMZ). Nano particles of an Iranian clinoptilolite zeolite were prepared by a ball-mill mechanical method and characterized by FT-IR, SEM and XRD. Best performance was exhibited at the membrane composition of SMZ : PVC : dioctyl phthalate (DOP) in the ratio of 4 : 32 : 64. This membrane worked well over a wide concentration range from to mol L−1 of with a Nernstian slope of mv per decade of concentration with detection limit of mol L−1 in a wide pH range of 6.8–10.7. The response time of the sensor is 5–10 s over a period of 2 months with good reproducibility. The selectivity coefficients of the proposed electrode towards various interfering ions were determined by FIM and SSM methods. The sensor was successfully used as indicator electrode in the potentiometric titration of against Pb(II) and determination of chromium in an electroplating wastewater sample. |
format | Article |
id | doaj-art-b2e7cae17eac47cfa39610f15cf2d84a |
institution | Kabale University |
issn | 2090-9063 2090-9071 |
language | English |
publishDate | 2013-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Chemistry |
spelling | doaj-art-b2e7cae17eac47cfa39610f15cf2d84a2025-02-03T05:57:09ZengWileyJournal of Chemistry2090-90632090-90712013-01-01201310.1155/2013/685290685290Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane ElectrodeAlireza Nezamzadeh-Ejhieh0Gholamhosein Raja1Department of Chemistry, Islamic Azad University, Shahreza Branch, P.O. Box 311-86145, Shahreza, Isfahan, IranDepartment of Chemistry, Islamic Azad University, Shahreza Branch, P.O. Box 311-86145, Shahreza, Isfahan, IranA novel chromate selective PVC membrane electrode was constructed using a hexadecyltrimethylammonium-surfactant modified zeolite (SMZ). Nano particles of an Iranian clinoptilolite zeolite were prepared by a ball-mill mechanical method and characterized by FT-IR, SEM and XRD. Best performance was exhibited at the membrane composition of SMZ : PVC : dioctyl phthalate (DOP) in the ratio of 4 : 32 : 64. This membrane worked well over a wide concentration range from to mol L−1 of with a Nernstian slope of mv per decade of concentration with detection limit of mol L−1 in a wide pH range of 6.8–10.7. The response time of the sensor is 5–10 s over a period of 2 months with good reproducibility. The selectivity coefficients of the proposed electrode towards various interfering ions were determined by FIM and SSM methods. The sensor was successfully used as indicator electrode in the potentiometric titration of against Pb(II) and determination of chromium in an electroplating wastewater sample.http://dx.doi.org/10.1155/2013/685290 |
spellingShingle | Alireza Nezamzadeh-Ejhieh Gholamhosein Raja Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane Electrode Journal of Chemistry |
title | Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane Electrode |
title_full | Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane Electrode |
title_fullStr | Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane Electrode |
title_full_unstemmed | Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane Electrode |
title_short | Modification of Nanoclinoptilolite Zeolite with Hexadecyltrimethylammonium Surfactant as an Active Ingredient of Chromate-Selective Membrane Electrode |
title_sort | modification of nanoclinoptilolite zeolite with hexadecyltrimethylammonium surfactant as an active ingredient of chromate selective membrane electrode |
url | http://dx.doi.org/10.1155/2013/685290 |
work_keys_str_mv | AT alirezanezamzadehejhieh modificationofnanoclinoptilolitezeolitewithhexadecyltrimethylammoniumsurfactantasanactiveingredientofchromateselectivemembraneelectrode AT gholamhoseinraja modificationofnanoclinoptilolitezeolitewithhexadecyltrimethylammoniumsurfactantasanactiveingredientofchromateselectivemembraneelectrode |