Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic Chips
A microfluidic chip with a microvalve based on a microhole array is proposed in this paper for the POCT of tumor marker proteins. In order to control the biochemical reaction time accurately and obtain a higher testing sensitivity, the parameters of the microhole array are optimized basing on the in...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2020-01-01
|
Series: | Journal of Analytical Methods in Chemistry |
Online Access: | http://dx.doi.org/10.1155/2020/8842890 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832551275030380544 |
---|---|
author | Cuimin Sun Hui You Yang Xie Ronald X. Xu |
author_facet | Cuimin Sun Hui You Yang Xie Ronald X. Xu |
author_sort | Cuimin Sun |
collection | DOAJ |
description | A microfluidic chip with a microvalve based on a microhole array is proposed in this paper for the POCT of tumor marker proteins. In order to control the biochemical reaction time accurately and obtain a higher testing sensitivity, the parameters of the microhole array are optimized basing on the investigation of the effects of the variation of those parameters on the fluid rate and the residual liquid value in the microvalve region. By conducting liquid flow experiments using microvalves based on microhole arrays with varying microstructural parameters, the residual rate of reaction products is demonstrated to be proportional to the depth and diameter of the microholes and inversely proportional to the distance between the microhole centers. A comprehensive analysis indicates that a microhole depth of 95 μm, a microhole diameter of 230 μm, and a distance between microhole centers of 250 μm not only ensure a sufficiently long delay time, but also reduce the residual rate of reaction products, thereby providing an optimum microvalve performance that maximizes the detection efficiency and accuracy of microfluidic chips. |
format | Article |
id | doaj-art-b2d72eb1498a4545b9eba475aa42cef1 |
institution | Kabale University |
issn | 2090-8865 2090-8873 |
language | English |
publishDate | 2020-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Analytical Methods in Chemistry |
spelling | doaj-art-b2d72eb1498a4545b9eba475aa42cef12025-02-03T06:04:35ZengWileyJournal of Analytical Methods in Chemistry2090-88652090-88732020-01-01202010.1155/2020/88428908842890Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic ChipsCuimin Sun0Hui You1Yang Xie2Ronald X. Xu3Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230001, ChinaDepartment of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230001, ChinaDepartment of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230001, ChinaDepartment of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230001, ChinaA microfluidic chip with a microvalve based on a microhole array is proposed in this paper for the POCT of tumor marker proteins. In order to control the biochemical reaction time accurately and obtain a higher testing sensitivity, the parameters of the microhole array are optimized basing on the investigation of the effects of the variation of those parameters on the fluid rate and the residual liquid value in the microvalve region. By conducting liquid flow experiments using microvalves based on microhole arrays with varying microstructural parameters, the residual rate of reaction products is demonstrated to be proportional to the depth and diameter of the microholes and inversely proportional to the distance between the microhole centers. A comprehensive analysis indicates that a microhole depth of 95 μm, a microhole diameter of 230 μm, and a distance between microhole centers of 250 μm not only ensure a sufficiently long delay time, but also reduce the residual rate of reaction products, thereby providing an optimum microvalve performance that maximizes the detection efficiency and accuracy of microfluidic chips.http://dx.doi.org/10.1155/2020/8842890 |
spellingShingle | Cuimin Sun Hui You Yang Xie Ronald X. Xu Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic Chips Journal of Analytical Methods in Chemistry |
title | Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic Chips |
title_full | Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic Chips |
title_fullStr | Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic Chips |
title_full_unstemmed | Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic Chips |
title_short | Performance Optimization of Microvalves Based on a Microhole Array for Microfluidic Chips |
title_sort | performance optimization of microvalves based on a microhole array for microfluidic chips |
url | http://dx.doi.org/10.1155/2020/8842890 |
work_keys_str_mv | AT cuiminsun performanceoptimizationofmicrovalvesbasedonamicroholearrayformicrofluidicchips AT huiyou performanceoptimizationofmicrovalvesbasedonamicroholearrayformicrofluidicchips AT yangxie performanceoptimizationofmicrovalvesbasedonamicroholearrayformicrofluidicchips AT ronaldxxu performanceoptimizationofmicrovalvesbasedonamicroholearrayformicrofluidicchips |