A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrode
In this report, we present electrochemical immunosensors for the detection of S. aureus bacteria on the basis of SPCE/PEI/АBSA/PSS layer-by-layer assembly as a recognition element. QCM measurements and AFM imaging ensure effective adhesion of S. aureus antibody to PEI surface and its strong interact...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-02-01
|
Series: | Sensing and Bio-Sensing Research |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2214180425000108 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832582187731386368 |
---|---|
author | Aleksei A. Evdokimov Anna A. Baldina Anna A. Nikitina Timur A. Aliev Artemii M. Zenkin Mikhail V. Zhukov Igor S. Pantyukhin Ekaterina V. Skorb Anton A. Muravev |
author_facet | Aleksei A. Evdokimov Anna A. Baldina Anna A. Nikitina Timur A. Aliev Artemii M. Zenkin Mikhail V. Zhukov Igor S. Pantyukhin Ekaterina V. Skorb Anton A. Muravev |
author_sort | Aleksei A. Evdokimov |
collection | DOAJ |
description | In this report, we present electrochemical immunosensors for the detection of S. aureus bacteria on the basis of SPCE/PEI/АBSA/PSS layer-by-layer assembly as a recognition element. QCM measurements and AFM imaging ensure effective adhesion of S. aureus antibody to PEI surface and its strong interactions with analyte through the PSS polyelectrolyte layer. Impedimetric detection of S. aureus gives the LOD of 1000 CFU/mL and the linear range from 104 to 107 CFU/mL and features facile assembly of recognition element and easy sampling. Voltammetric detection of the formation of the sandwich immunocomplex with secondary antibody in the outermost layer (AB–AG–AB-HRP) not only decreases the detection limit to 230 CFU/mL and expands the linear range of detection to 103–108 CFU/mL, but also could detect S. aureus bacteria with a portable open-source custom potentiostat in voltammetric mode, which is promising for non-invasive point-of-care monitoring of pathogens and addresses issues of antibody-based sensors, such as high cost and difficult chemical modification. |
format | Article |
id | doaj-art-b107c65f8e5840af90a218abd2e82359 |
institution | Kabale University |
issn | 2214-1804 |
language | English |
publishDate | 2025-02-01 |
publisher | Elsevier |
record_format | Article |
series | Sensing and Bio-Sensing Research |
spelling | doaj-art-b107c65f8e5840af90a218abd2e823592025-01-30T05:14:14ZengElsevierSensing and Bio-Sensing Research2214-18042025-02-0147100744A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrodeAleksei A. Evdokimov0Anna A. Baldina1Anna A. Nikitina2Timur A. Aliev3Artemii M. Zenkin4Mikhail V. Zhukov5Igor S. Pantyukhin6Ekaterina V. Skorb7Anton A. Muravev8Infochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaInfochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaInfochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaInfochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaInfochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaInfochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaInfochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaCorresponding authors.; Infochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaCorresponding authors.; Infochemistry Scientific Center, ITMO University, Lomonosov Str. 9, 191002 Saint Petersburg, RussiaIn this report, we present electrochemical immunosensors for the detection of S. aureus bacteria on the basis of SPCE/PEI/АBSA/PSS layer-by-layer assembly as a recognition element. QCM measurements and AFM imaging ensure effective adhesion of S. aureus antibody to PEI surface and its strong interactions with analyte through the PSS polyelectrolyte layer. Impedimetric detection of S. aureus gives the LOD of 1000 CFU/mL and the linear range from 104 to 107 CFU/mL and features facile assembly of recognition element and easy sampling. Voltammetric detection of the formation of the sandwich immunocomplex with secondary antibody in the outermost layer (AB–AG–AB-HRP) not only decreases the detection limit to 230 CFU/mL and expands the linear range of detection to 103–108 CFU/mL, but also could detect S. aureus bacteria with a portable open-source custom potentiostat in voltammetric mode, which is promising for non-invasive point-of-care monitoring of pathogens and addresses issues of antibody-based sensors, such as high cost and difficult chemical modification.http://www.sciencedirect.com/science/article/pii/S2214180425000108Polyelectrolyte assemblySPCEImmunoassayAntibody–S. aureus Antigen Complex |
spellingShingle | Aleksei A. Evdokimov Anna A. Baldina Anna A. Nikitina Timur A. Aliev Artemii M. Zenkin Mikhail V. Zhukov Igor S. Pantyukhin Ekaterina V. Skorb Anton A. Muravev A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrode Sensing and Bio-Sensing Research Polyelectrolyte assembly SPCE Immunoassay Antibody–S. aureus Antigen Complex |
title | A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrode |
title_full | A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrode |
title_fullStr | A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrode |
title_full_unstemmed | A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrode |
title_short | A portable electrochemical immunosensor for detection of S. aureus based on polyelectrolyte-modified screen-printed carbon electrode |
title_sort | portable electrochemical immunosensor for detection of s aureus based on polyelectrolyte modified screen printed carbon electrode |
topic | Polyelectrolyte assembly SPCE Immunoassay Antibody–S. aureus Antigen Complex |
url | http://www.sciencedirect.com/science/article/pii/S2214180425000108 |
work_keys_str_mv | AT alekseiaevdokimov aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT annaabaldina aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT annaanikitina aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT timuraaliev aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT artemiimzenkin aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT mikhailvzhukov aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT igorspantyukhin aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT ekaterinavskorb aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT antonamuravev aportableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT alekseiaevdokimov portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT annaabaldina portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT annaanikitina portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT timuraaliev portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT artemiimzenkin portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT mikhailvzhukov portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT igorspantyukhin portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT ekaterinavskorb portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode AT antonamuravev portableelectrochemicalimmunosensorfordetectionofsaureusbasedonpolyelectrolytemodifiedscreenprintedcarbonelectrode |