Catheter Fracture and Embolization Related to an Arm Venous Port

This 55-year-old female had a chest X-ray during a follow-up visit for the management of her breast cancer. The chest X-ray demonstrated an embolized venous catheter superimposed upon the mediastinum. It was determined that the catheter of the patient's arm port had fractured and embolized to t...

Full description

Saved in:
Bibliographic Details
Main Author: Brent E. Burbridge
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:Case Reports in Radiology
Online Access:http://dx.doi.org/10.1155/2011/763284
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This 55-year-old female had a chest X-ray during a follow-up visit for the management of her breast cancer. The chest X-ray demonstrated an embolized venous catheter superimposed upon the mediastinum. It was determined that the catheter of the patient's arm port had fractured and embolized to the pulmonary circulation. The catheter was retrieved, in the interventional radiology suite, under fluoroscopic guidance. The patient suffered no ill effects. Subsequently, one day later, the old vein port was removed and a new arm port and associated catheter were implanted to facilitate the delivery of the patient's ongoing chemotherapy.
ISSN:2090-6862
2090-6870