EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALS

Hazen-William’s equation is usually used to determine the hydraulic head loss when designing drip irrigation systems. The mentioned equation is suggested for pipes with diameters greater than 75 mm and flow rates above 2.3 l/s. However, lateral pipes with 16 to 32 mm diameters are generally used for...

Full description

Saved in:
Bibliographic Details
Main Authors: Sh. Shafaei, Gh. Zarei, K. Ebrahimi, Sh. Soleimani, M. Shamsi
Format: Article
Language:fas
Published: Sharif University of Technology 2024-12-01
Series:مهندسی عمران شریف
Subjects:
Online Access:https://sjce.journals.sharif.edu/article_23556_512464a7b8dacc6896c8537d3550b044.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832572296092450816
author Sh. Shafaei
Gh. Zarei
K. Ebrahimi
Sh. Soleimani
M. Shamsi
author_facet Sh. Shafaei
Gh. Zarei
K. Ebrahimi
Sh. Soleimani
M. Shamsi
author_sort Sh. Shafaei
collection DOAJ
description Hazen-William’s equation is usually used to determine the hydraulic head loss when designing drip irrigation systems. The mentioned equation is suggested for pipes with diameters greater than 75 mm and flow rates above 2.3 l/s. However, lateral pipes with 16 to 32 mm diameters are generally used for trickle irrigation. In this case, the calculated hydraulic head loss is lower than the actual hydraulic head loss, and subsequently, the hydraulic pressure at the desired point will be lower than the required value. In other words, the output flow from the droppers will be reduced, and the water distribution uniformity will be less than expected. Herein, using laboratory models and polyethylene pipes with a diameter of 16, 20, 25, and 32 mm, the amount of hydraulic loss was measured for different flow rates and according to the permissible velocity limits. Hydraulic pressures were measured using a data logger, with one record for each second, and the discharge was adjusted volumetrically. A bypass pipe was installed on the physical model to control the discharge and the hydraulic pressure. The amount of hydraulic head loss was measured for different flow rates in the permissible flow velocity range (1-2 m/s). Then, by analyzing the recorded data, a new relationship was obtained that calculates the amount of hydraulic head loss in 16 to 32-mm pipes as a flow rate and pipe diameter function. The Hazen-Williams equation was compared with the results of Moody, Churchill, and Colebrook methods and the actual measured values. According to the results, the most significant error between the measured and the calculated head loss was for the Colebrook & White equation for the 25 mm pipe, and the smallest error was for the same equation for the 32 mm pipe. The obtained relationship is recommended for polyethylene pipes with a diameter of 16 to 32 mm and a Reynolds number above 2000 with high confidence. One of the advantages of the obtained relationship is its independence from the Hazen-Williams roughness coefficient and its remarkable accuracy.
format Article
id doaj-art-ad44bba82f3546278116ae2d45fde2f5
institution Kabale University
issn 2676-4768
2676-4776
language fas
publishDate 2024-12-01
publisher Sharif University of Technology
record_format Article
series مهندسی عمران شریف
spelling doaj-art-ad44bba82f3546278116ae2d45fde2f52025-02-02T10:57:49ZfasSharif University of Technologyمهندسی عمران شریف2676-47682676-47762024-12-0140331110.24200/j30.2024.62619.323423556EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALSSh. Shafaei0Gh. Zarei1K. Ebrahimi2Sh. Soleimani3M. Shamsi4Graduated MSc. in Faculty of Irrigation and Drainage Engineering, University of Tehran, Karaj, IRAN.Associate Professor, Agricultural Engineering Research Institute, Ministry of Agriculture – Jahad, Karaj, IRAN.* Professor Department of Environmental Sciences and Technologies, Faculty of Energy and Sustainable Resources Engineering, University of Tehran, Tehran, IRAN.Postdoc Associate, Rice University, Houston, Texas, United States,Graduated MSc. in Faculty of Irrigation and Drainage Engineering, University of Tehran, Karaj, IRAN.Hazen-William’s equation is usually used to determine the hydraulic head loss when designing drip irrigation systems. The mentioned equation is suggested for pipes with diameters greater than 75 mm and flow rates above 2.3 l/s. However, lateral pipes with 16 to 32 mm diameters are generally used for trickle irrigation. In this case, the calculated hydraulic head loss is lower than the actual hydraulic head loss, and subsequently, the hydraulic pressure at the desired point will be lower than the required value. In other words, the output flow from the droppers will be reduced, and the water distribution uniformity will be less than expected. Herein, using laboratory models and polyethylene pipes with a diameter of 16, 20, 25, and 32 mm, the amount of hydraulic loss was measured for different flow rates and according to the permissible velocity limits. Hydraulic pressures were measured using a data logger, with one record for each second, and the discharge was adjusted volumetrically. A bypass pipe was installed on the physical model to control the discharge and the hydraulic pressure. The amount of hydraulic head loss was measured for different flow rates in the permissible flow velocity range (1-2 m/s). Then, by analyzing the recorded data, a new relationship was obtained that calculates the amount of hydraulic head loss in 16 to 32-mm pipes as a flow rate and pipe diameter function. The Hazen-Williams equation was compared with the results of Moody, Churchill, and Colebrook methods and the actual measured values. According to the results, the most significant error between the measured and the calculated head loss was for the Colebrook & White equation for the 25 mm pipe, and the smallest error was for the same equation for the 32 mm pipe. The obtained relationship is recommended for polyethylene pipes with a diameter of 16 to 32 mm and a Reynolds number above 2000 with high confidence. One of the advantages of the obtained relationship is its independence from the Hazen-Williams roughness coefficient and its remarkable accuracy.https://sjce.journals.sharif.edu/article_23556_512464a7b8dacc6896c8537d3550b044.pdfdrip irrigationhydraulic losslaboratory modelhazen-williams
spellingShingle Sh. Shafaei
Gh. Zarei
K. Ebrahimi
Sh. Soleimani
M. Shamsi
EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALS
مهندسی عمران شریف
drip irrigation
hydraulic loss
laboratory model
hazen-williams
title EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALS
title_full EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALS
title_fullStr EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALS
title_full_unstemmed EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALS
title_short EVALUATION OF THE WIDELY-USED EQUATIONS OF HYDRAULIC LOSS CALCULATION AND CALIBRATION OF THE HAZEN-WILLIAMS EQUATION IN DRIP IRRIGATION LATERALS
title_sort evaluation of the widely used equations of hydraulic loss calculation and calibration of the hazen williams equation in drip irrigation laterals
topic drip irrigation
hydraulic loss
laboratory model
hazen-williams
url https://sjce.journals.sharif.edu/article_23556_512464a7b8dacc6896c8537d3550b044.pdf
work_keys_str_mv AT shshafaei evaluationofthewidelyusedequationsofhydrauliclosscalculationandcalibrationofthehazenwilliamsequationindripirrigationlaterals
AT ghzarei evaluationofthewidelyusedequationsofhydrauliclosscalculationandcalibrationofthehazenwilliamsequationindripirrigationlaterals
AT kebrahimi evaluationofthewidelyusedequationsofhydrauliclosscalculationandcalibrationofthehazenwilliamsequationindripirrigationlaterals
AT shsoleimani evaluationofthewidelyusedequationsofhydrauliclosscalculationandcalibrationofthehazenwilliamsequationindripirrigationlaterals
AT mshamsi evaluationofthewidelyusedequationsofhydrauliclosscalculationandcalibrationofthehazenwilliamsequationindripirrigationlaterals