Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometry

The remarkable advancement in smartphone cameras has revolutionized their potential as highly accessible, portable, and manageable detectors in various analytical approaches. In this study, we developed a novel and cost-effective method for the simultaneous determination of four drugs (Tolperisone H...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamed Rizk, Emad Ramzy, Safaa Toubar, Amr M. Mahmoud, Marwa I. Helmy
Format: Article
Language:English
Published: Elsevier 2025-08-01
Series:Talanta Open
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666831925000189
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832540414196842496
author Mohamed Rizk
Emad Ramzy
Safaa Toubar
Amr M. Mahmoud
Marwa I. Helmy
author_facet Mohamed Rizk
Emad Ramzy
Safaa Toubar
Amr M. Mahmoud
Marwa I. Helmy
author_sort Mohamed Rizk
collection DOAJ
description The remarkable advancement in smartphone cameras has revolutionized their potential as highly accessible, portable, and manageable detectors in various analytical approaches. In this study, we developed a novel and cost-effective method for the simultaneous determination of four drugs (Tolperisone HCl (TOLP), aceclofenac(ACEC), Paracetamol (PARA), and etodolac (ETOD)). Our innovative approach combines high-performance thin-layer chromatography (HPTLC) with a smartphone's camera. Initially, chromatographic separation has been achieved utilizing HPTLC plates, employing an environmentally friendly mobile phase consisting of a mixture of ethyl acetate, methanol, and glacial acetic acid (8.5:1.5:0.25, by volume). The developed plates were visualized using a UV lamp and captured using the rear-facing camera of a smartphone fixed onto a specially designed chamber with a UV illumination source. Using ImageJ, a freely available image analysis program, the drug spot intensities were measured throughout a concentration range of 1.0–7.0 µg/band. Furthermore, the study expanded to include a comparison between the obtained results and a conventional benchtop densitometry method at a wavelength of 276.0 nm. The densitometry method exhibited a linear response within the range of 100.0 - 700.0 ng/band for TOLP, 100.0 - 600.0 ng/band for ACEC, and 150.0 - 600.0 ng/band for PARA and ETOD. The proposed HPTLC/smartphone method demonstrated its advantages of being fast, simple, reliable, and environmentally friendly, making it an outstanding platform for analyzing commercially available combined tablets. To evaluate the environmental impact and sustainability of the constructed methods and compare them with other published methods reported in the literature, the whiteness of the developed methods utilizing the RGB 12 algorithm combined with the two highly cited greenness assessment metrics, the analytical Eco-scale (AES) and the Analytical GREEnness (AGREE), were employed.
format Article
id doaj-art-ad38fe9f69ac432ca55e3484e95add30
institution Kabale University
issn 2666-8319
language English
publishDate 2025-08-01
publisher Elsevier
record_format Article
series Talanta Open
spelling doaj-art-ad38fe9f69ac432ca55e3484e95add302025-02-05T04:32:45ZengElsevierTalanta Open2666-83192025-08-0111100415Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometryMohamed Rizk0Emad Ramzy1Safaa Toubar2Amr M. Mahmoud3Marwa I. Helmy4Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan 11795, Cairo, EgyptAnalytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan 11795, Cairo, Egypt; Corresponding authors.Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan 11795, Cairo, EgyptAnalytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo 11562, Egypt; Corresponding authors.Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan 11795, Cairo, EgyptThe remarkable advancement in smartphone cameras has revolutionized their potential as highly accessible, portable, and manageable detectors in various analytical approaches. In this study, we developed a novel and cost-effective method for the simultaneous determination of four drugs (Tolperisone HCl (TOLP), aceclofenac(ACEC), Paracetamol (PARA), and etodolac (ETOD)). Our innovative approach combines high-performance thin-layer chromatography (HPTLC) with a smartphone's camera. Initially, chromatographic separation has been achieved utilizing HPTLC plates, employing an environmentally friendly mobile phase consisting of a mixture of ethyl acetate, methanol, and glacial acetic acid (8.5:1.5:0.25, by volume). The developed plates were visualized using a UV lamp and captured using the rear-facing camera of a smartphone fixed onto a specially designed chamber with a UV illumination source. Using ImageJ, a freely available image analysis program, the drug spot intensities were measured throughout a concentration range of 1.0–7.0 µg/band. Furthermore, the study expanded to include a comparison between the obtained results and a conventional benchtop densitometry method at a wavelength of 276.0 nm. The densitometry method exhibited a linear response within the range of 100.0 - 700.0 ng/band for TOLP, 100.0 - 600.0 ng/band for ACEC, and 150.0 - 600.0 ng/band for PARA and ETOD. The proposed HPTLC/smartphone method demonstrated its advantages of being fast, simple, reliable, and environmentally friendly, making it an outstanding platform for analyzing commercially available combined tablets. To evaluate the environmental impact and sustainability of the constructed methods and compare them with other published methods reported in the literature, the whiteness of the developed methods utilizing the RGB 12 algorithm combined with the two highly cited greenness assessment metrics, the analytical Eco-scale (AES) and the Analytical GREEnness (AGREE), were employed.http://www.sciencedirect.com/science/article/pii/S2666831925000189Multi-analyte analysisHigh-performance thin-layer chromatographySmartphoneSustainability assessment
spellingShingle Mohamed Rizk
Emad Ramzy
Safaa Toubar
Amr M. Mahmoud
Marwa I. Helmy
Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometry
Talanta Open
Multi-analyte analysis
High-performance thin-layer chromatography
Smartphone
Sustainability assessment
title Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometry
title_full Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometry
title_fullStr Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometry
title_full_unstemmed Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometry
title_short Sustainable and smart multi-analyte HPTLC determination of tolperisone HCl together with three pain killers using smartphone camera as a detector: Comparative study with benchtop densitometry
title_sort sustainable and smart multi analyte hptlc determination of tolperisone hcl together with three pain killers using smartphone camera as a detector comparative study with benchtop densitometry
topic Multi-analyte analysis
High-performance thin-layer chromatography
Smartphone
Sustainability assessment
url http://www.sciencedirect.com/science/article/pii/S2666831925000189
work_keys_str_mv AT mohamedrizk sustainableandsmartmultianalytehptlcdeterminationoftolperisonehcltogetherwiththreepainkillersusingsmartphonecameraasadetectorcomparativestudywithbenchtopdensitometry
AT emadramzy sustainableandsmartmultianalytehptlcdeterminationoftolperisonehcltogetherwiththreepainkillersusingsmartphonecameraasadetectorcomparativestudywithbenchtopdensitometry
AT safaatoubar sustainableandsmartmultianalytehptlcdeterminationoftolperisonehcltogetherwiththreepainkillersusingsmartphonecameraasadetectorcomparativestudywithbenchtopdensitometry
AT amrmmahmoud sustainableandsmartmultianalytehptlcdeterminationoftolperisonehcltogetherwiththreepainkillersusingsmartphonecameraasadetectorcomparativestudywithbenchtopdensitometry
AT marwaihelmy sustainableandsmartmultianalytehptlcdeterminationoftolperisonehcltogetherwiththreepainkillersusingsmartphonecameraasadetectorcomparativestudywithbenchtopdensitometry