A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
CISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cab...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2025-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/10848110/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832576777285795840 |
---|---|
author | Xinglong Wu Alessandro Grande Xiaokang Liu Flavia Grassi Giordano Spadacini Sergio A. Pignari Fabio Vallarino Luca Ghezzi |
author_facet | Xinglong Wu Alessandro Grande Xiaokang Liu Flavia Grassi Giordano Spadacini Sergio A. Pignari Fabio Vallarino Luca Ghezzi |
author_sort | Xinglong Wu |
collection | DOAJ |
description | CISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cable bundle that radiates significantly, the work proposes a fast and simple pre-compliance radiated emission evaluation method based on cascaded Hertzian dipoles and its radiation theory. Several factors in the CISPR 11/32 test setups are integrated into this evaluation method to mimic a real test procedure. The accuracy of the proposed method is validated by an experimental test. A systematic analysis of the accuracy and applicability of the proposed method is also provided, showing that the method presents a simple, reliable and easy-to-be-implemented prediction tool for early-stage pre-compliance radiation evaluation, according to CISPR 11/32 testing. |
format | Article |
id | doaj-art-ad23080764a34492a7a57c3698fad02e |
institution | Kabale University |
issn | 2169-3536 |
language | English |
publishDate | 2025-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj-art-ad23080764a34492a7a57c3698fad02e2025-01-31T00:01:47ZengIEEEIEEE Access2169-35362025-01-0113190401904810.1109/ACCESS.2025.353246010848110A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32Xinglong Wu0https://orcid.org/0000-0002-0564-6690Alessandro Grande1https://orcid.org/0009-0000-1193-259XXiaokang Liu2https://orcid.org/0000-0001-5614-1601Flavia Grassi3https://orcid.org/0000-0001-6844-8766Giordano Spadacini4https://orcid.org/0000-0002-9778-693XSergio A. Pignari5https://orcid.org/0000-0002-6657-1530Fabio Vallarino6Luca Ghezzi7https://orcid.org/0000-0002-5868-9387Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyABB Electrification-Smart Buildings Division, Vittuone, ItalyABB Electrification-Smart Buildings Division, Vittuone, ItalyCISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cable bundle that radiates significantly, the work proposes a fast and simple pre-compliance radiated emission evaluation method based on cascaded Hertzian dipoles and its radiation theory. Several factors in the CISPR 11/32 test setups are integrated into this evaluation method to mimic a real test procedure. The accuracy of the proposed method is validated by an experimental test. A systematic analysis of the accuracy and applicability of the proposed method is also provided, showing that the method presents a simple, reliable and easy-to-be-implemented prediction tool for early-stage pre-compliance radiation evaluation, according to CISPR 11/32 testing.https://ieeexplore.ieee.org/document/10848110/CISPR 11CISPR 32common-mode currentHertzian dipoleradiated emission |
spellingShingle | Xinglong Wu Alessandro Grande Xiaokang Liu Flavia Grassi Giordano Spadacini Sergio A. Pignari Fabio Vallarino Luca Ghezzi A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32 IEEE Access CISPR 11 CISPR 32 common-mode current Hertzian dipole radiated emission |
title | A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32 |
title_full | A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32 |
title_fullStr | A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32 |
title_full_unstemmed | A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32 |
title_short | A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32 |
title_sort | simple cable radiated emission evaluation method for table top setups according to cispr 11 and cispr 32 |
topic | CISPR 11 CISPR 32 common-mode current Hertzian dipole radiated emission |
url | https://ieeexplore.ieee.org/document/10848110/ |
work_keys_str_mv | AT xinglongwu asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT alessandrogrande asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT xiaokangliu asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT flaviagrassi asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT giordanospadacini asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT sergioapignari asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT fabiovallarino asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT lucaghezzi asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT xinglongwu simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT alessandrogrande simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT xiaokangliu simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT flaviagrassi simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT giordanospadacini simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT sergioapignari simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT fabiovallarino simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 AT lucaghezzi simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32 |