A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32

CISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cab...

Full description

Saved in:
Bibliographic Details
Main Authors: Xinglong Wu, Alessandro Grande, Xiaokang Liu, Flavia Grassi, Giordano Spadacini, Sergio A. Pignari, Fabio Vallarino, Luca Ghezzi
Format: Article
Language:English
Published: IEEE 2025-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10848110/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832576777285795840
author Xinglong Wu
Alessandro Grande
Xiaokang Liu
Flavia Grassi
Giordano Spadacini
Sergio A. Pignari
Fabio Vallarino
Luca Ghezzi
author_facet Xinglong Wu
Alessandro Grande
Xiaokang Liu
Flavia Grassi
Giordano Spadacini
Sergio A. Pignari
Fabio Vallarino
Luca Ghezzi
author_sort Xinglong Wu
collection DOAJ
description CISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cable bundle that radiates significantly, the work proposes a fast and simple pre-compliance radiated emission evaluation method based on cascaded Hertzian dipoles and its radiation theory. Several factors in the CISPR 11/32 test setups are integrated into this evaluation method to mimic a real test procedure. The accuracy of the proposed method is validated by an experimental test. A systematic analysis of the accuracy and applicability of the proposed method is also provided, showing that the method presents a simple, reliable and easy-to-be-implemented prediction tool for early-stage pre-compliance radiation evaluation, according to CISPR 11/32 testing.
format Article
id doaj-art-ad23080764a34492a7a57c3698fad02e
institution Kabale University
issn 2169-3536
language English
publishDate 2025-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj-art-ad23080764a34492a7a57c3698fad02e2025-01-31T00:01:47ZengIEEEIEEE Access2169-35362025-01-0113190401904810.1109/ACCESS.2025.353246010848110A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32Xinglong Wu0https://orcid.org/0000-0002-0564-6690Alessandro Grande1https://orcid.org/0009-0000-1193-259XXiaokang Liu2https://orcid.org/0000-0001-5614-1601Flavia Grassi3https://orcid.org/0000-0001-6844-8766Giordano Spadacini4https://orcid.org/0000-0002-9778-693XSergio A. Pignari5https://orcid.org/0000-0002-6657-1530Fabio Vallarino6Luca Ghezzi7https://orcid.org/0000-0002-5868-9387Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, ItalyABB Electrification-Smart Buildings Division, Vittuone, ItalyABB Electrification-Smart Buildings Division, Vittuone, ItalyCISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cable bundle that radiates significantly, the work proposes a fast and simple pre-compliance radiated emission evaluation method based on cascaded Hertzian dipoles and its radiation theory. Several factors in the CISPR 11/32 test setups are integrated into this evaluation method to mimic a real test procedure. The accuracy of the proposed method is validated by an experimental test. A systematic analysis of the accuracy and applicability of the proposed method is also provided, showing that the method presents a simple, reliable and easy-to-be-implemented prediction tool for early-stage pre-compliance radiation evaluation, according to CISPR 11/32 testing.https://ieeexplore.ieee.org/document/10848110/CISPR 11CISPR 32common-mode currentHertzian dipoleradiated emission
spellingShingle Xinglong Wu
Alessandro Grande
Xiaokang Liu
Flavia Grassi
Giordano Spadacini
Sergio A. Pignari
Fabio Vallarino
Luca Ghezzi
A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
IEEE Access
CISPR 11
CISPR 32
common-mode current
Hertzian dipole
radiated emission
title A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
title_full A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
title_fullStr A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
title_full_unstemmed A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
title_short A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
title_sort simple cable radiated emission evaluation method for table top setups according to cispr 11 and cispr 32
topic CISPR 11
CISPR 32
common-mode current
Hertzian dipole
radiated emission
url https://ieeexplore.ieee.org/document/10848110/
work_keys_str_mv AT xinglongwu asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT alessandrogrande asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT xiaokangliu asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT flaviagrassi asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT giordanospadacini asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT sergioapignari asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT fabiovallarino asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT lucaghezzi asimplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT xinglongwu simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT alessandrogrande simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT xiaokangliu simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT flaviagrassi simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT giordanospadacini simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT sergioapignari simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT fabiovallarino simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32
AT lucaghezzi simplecableradiatedemissionevaluationmethodfortabletopsetupsaccordingtocispr11andcispr32