High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms
A novel, simple and robust high-performance liquid chromatography (HPLC) method was developed and validated for simultaneous determination of xipamide (XIP), triamterene (TRI) and hydrochlorothiazide (HCT) in their bulk powders and dosage forms. Chromatographic separation was carried out in less tha...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sciendo
2016-03-01
|
Series: | Acta Pharmaceutica |
Subjects: | |
Online Access: | https://doi.org/10.1515/acph-2016-0022 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832570157747142656 |
---|---|
author | Abd El-Hay Soad S. Hashem Hisham Gouda Ayman A. |
author_facet | Abd El-Hay Soad S. Hashem Hisham Gouda Ayman A. |
author_sort | Abd El-Hay Soad S. |
collection | DOAJ |
description | A novel, simple and robust high-performance liquid chromatography (HPLC) method was developed and validated for simultaneous determination of xipamide (XIP), triamterene (TRI) and hydrochlorothiazide (HCT) in their bulk powders and dosage forms. Chromatographic separation was carried out in less than two minutes. The separation was performed on a RP C-18 stationary phase with an isocratic elution system consisting of 0.03 mol L−1 orthophosphoric acid (pH 2.3) and acetonitrile (ACN) as the mobile phase in the ratio of 50:50, at 2.0 mL min−1 flow rate at room temperature. Detection was performed at 220 nm. Validation was performed concerning system suitability, limits of detection and quantitation, accuracy, precision, linearity and robustness. Calibration curves were rectilinear over the range of 0.195–100 μg mL−1 for all the drugs studied. Recovery values were 99.9, 99.6 and 99.0 % for XIP, TRI and HCT, respectively. The method was applied to simultaneous determination of the studied analytes in their pharmaceutical dosage forms. |
format | Article |
id | doaj-art-ac4afa676a1a40f2bae19a9c0317d6d8 |
institution | Kabale University |
issn | 1846-9558 |
language | English |
publishDate | 2016-03-01 |
publisher | Sciendo |
record_format | Article |
series | Acta Pharmaceutica |
spelling | doaj-art-ac4afa676a1a40f2bae19a9c0317d6d82025-02-02T17:00:58ZengSciendoActa Pharmaceutica1846-95582016-03-0166110911810.1515/acph-2016-0022acph-2016-0022High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage formsAbd El-Hay Soad S.0Hashem Hisham1Gouda Ayman A.2 Faculty of Pharmacy, Pharmaceutical Chemistry Department, King Abdulaziz University, Saudi Arabia Faculty of Pharmacy, Department of Analytical Chemistry, Zagazig University, Egypt Faculty of Science, Department of Analytical Chemistry, Zagazig University, EgyptA novel, simple and robust high-performance liquid chromatography (HPLC) method was developed and validated for simultaneous determination of xipamide (XIP), triamterene (TRI) and hydrochlorothiazide (HCT) in their bulk powders and dosage forms. Chromatographic separation was carried out in less than two minutes. The separation was performed on a RP C-18 stationary phase with an isocratic elution system consisting of 0.03 mol L−1 orthophosphoric acid (pH 2.3) and acetonitrile (ACN) as the mobile phase in the ratio of 50:50, at 2.0 mL min−1 flow rate at room temperature. Detection was performed at 220 nm. Validation was performed concerning system suitability, limits of detection and quantitation, accuracy, precision, linearity and robustness. Calibration curves were rectilinear over the range of 0.195–100 μg mL−1 for all the drugs studied. Recovery values were 99.9, 99.6 and 99.0 % for XIP, TRI and HCT, respectively. The method was applied to simultaneous determination of the studied analytes in their pharmaceutical dosage forms.https://doi.org/10.1515/acph-2016-0022xipamidetriamterenehydrochlorothiazidehplcsimultaneous analysis |
spellingShingle | Abd El-Hay Soad S. Hashem Hisham Gouda Ayman A. High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms Acta Pharmaceutica xipamide triamterene hydrochlorothiazide hplc simultaneous analysis |
title | High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms |
title_full | High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms |
title_fullStr | High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms |
title_full_unstemmed | High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms |
title_short | High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms |
title_sort | high performance liquid chromatography for simultaneous determination of xipamide triamterene and hydrochlorothiazide in bulk drug samples and dosage forms |
topic | xipamide triamterene hydrochlorothiazide hplc simultaneous analysis |
url | https://doi.org/10.1515/acph-2016-0022 |
work_keys_str_mv | AT abdelhaysoads highperformanceliquidchromatographyforsimultaneousdeterminationofxipamidetriamtereneandhydrochlorothiazideinbulkdrugsamplesanddosageforms AT hashemhisham highperformanceliquidchromatographyforsimultaneousdeterminationofxipamidetriamtereneandhydrochlorothiazideinbulkdrugsamplesanddosageforms AT goudaaymana highperformanceliquidchromatographyforsimultaneousdeterminationofxipamidetriamtereneandhydrochlorothiazideinbulkdrugsamplesanddosageforms |