Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia
A high demand for air conditioning systems exists in hot and humid regions because of the warm climate during the year. The high energy consumption of conventional air conditioning system is the reason for our investigation of the solar desiccant cooling system as an energy-efficient cooling system....
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2014-01-01
|
Series: | International Journal of Photoenergy |
Online Access: | http://dx.doi.org/10.1155/2014/843617 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832558266051198976 |
---|---|
author | M. M. S. Dezfouli S. Mat G. Pirasteh K. S. M. Sahari K. Sopian M. H. Ruslan |
author_facet | M. M. S. Dezfouli S. Mat G. Pirasteh K. S. M. Sahari K. Sopian M. H. Ruslan |
author_sort | M. M. S. Dezfouli |
collection | DOAJ |
description | A high demand for air conditioning systems exists in hot and humid regions because of the warm climate during the year. The high energy consumption of conventional air conditioning system is the reason for our investigation of the solar desiccant cooling system as an energy-efficient cooling system. Four model configurations were considered to determine the best configuration of a solar desiccant cooling system: one-stage ventilation, one-stage recirculation, two-stage ventilation, and two-stage recirculation. These models were stimulated for 8,760 hr of operation under hot and humid weather in Malaysia. Several parameters (i.e., coefficient of performance or COP, room temperature and humidity ratio, and the solar fraction of each system) were evaluated by detecting the temperature and humidity ratio of the different points of each configuration by TRNSYS simulation. The latent and sensible loads of the test room were 0.875 kW and 2.625 kW, respectively. By investigating the simulation results of the four systems, the ventilation modes were found to be higher than the recirculation modes in the one- and two-stage solar desiccant cooling systems. The isothermal dehumidification COP of the two-stage ventilation was higher than that of the two-stage recirculation. Hence, the two-stage ventilation mode desiccant cooling system in a hot and humid area has higher efficiency than the other configurations. |
format | Article |
id | doaj-art-ac49f838201b453e8d73c63ee15a6176 |
institution | Kabale University |
issn | 1110-662X 1687-529X |
language | English |
publishDate | 2014-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Photoenergy |
spelling | doaj-art-ac49f838201b453e8d73c63ee15a61762025-02-03T01:32:47ZengWileyInternational Journal of Photoenergy1110-662X1687-529X2014-01-01201410.1155/2014/843617843617Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in MalaysiaM. M. S. Dezfouli0S. Mat1G. Pirasteh2K. S. M. Sahari3K. Sopian4M. H. Ruslan5Solar Energy Research Institute (SERI), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, MalaysiaSolar Energy Research Institute (SERI), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, MalaysiaDepartment of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, MalaysiaDepartment of Mechanical Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, 43000 Kajang, Selangor, MalaysiaSolar Energy Research Institute (SERI), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, MalaysiaSolar Energy Research Institute (SERI), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, MalaysiaA high demand for air conditioning systems exists in hot and humid regions because of the warm climate during the year. The high energy consumption of conventional air conditioning system is the reason for our investigation of the solar desiccant cooling system as an energy-efficient cooling system. Four model configurations were considered to determine the best configuration of a solar desiccant cooling system: one-stage ventilation, one-stage recirculation, two-stage ventilation, and two-stage recirculation. These models were stimulated for 8,760 hr of operation under hot and humid weather in Malaysia. Several parameters (i.e., coefficient of performance or COP, room temperature and humidity ratio, and the solar fraction of each system) were evaluated by detecting the temperature and humidity ratio of the different points of each configuration by TRNSYS simulation. The latent and sensible loads of the test room were 0.875 kW and 2.625 kW, respectively. By investigating the simulation results of the four systems, the ventilation modes were found to be higher than the recirculation modes in the one- and two-stage solar desiccant cooling systems. The isothermal dehumidification COP of the two-stage ventilation was higher than that of the two-stage recirculation. Hence, the two-stage ventilation mode desiccant cooling system in a hot and humid area has higher efficiency than the other configurations.http://dx.doi.org/10.1155/2014/843617 |
spellingShingle | M. M. S. Dezfouli S. Mat G. Pirasteh K. S. M. Sahari K. Sopian M. H. Ruslan Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia International Journal of Photoenergy |
title | Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia |
title_full | Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia |
title_fullStr | Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia |
title_full_unstemmed | Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia |
title_short | Simulation Analysis of the Four Configurations of Solar Desiccant Cooling System Using Evaporative Cooling in Tropical Weather in Malaysia |
title_sort | simulation analysis of the four configurations of solar desiccant cooling system using evaporative cooling in tropical weather in malaysia |
url | http://dx.doi.org/10.1155/2014/843617 |
work_keys_str_mv | AT mmsdezfouli simulationanalysisofthefourconfigurationsofsolardesiccantcoolingsystemusingevaporativecoolingintropicalweatherinmalaysia AT smat simulationanalysisofthefourconfigurationsofsolardesiccantcoolingsystemusingevaporativecoolingintropicalweatherinmalaysia AT gpirasteh simulationanalysisofthefourconfigurationsofsolardesiccantcoolingsystemusingevaporativecoolingintropicalweatherinmalaysia AT ksmsahari simulationanalysisofthefourconfigurationsofsolardesiccantcoolingsystemusingevaporativecoolingintropicalweatherinmalaysia AT ksopian simulationanalysisofthefourconfigurationsofsolardesiccantcoolingsystemusingevaporativecoolingintropicalweatherinmalaysia AT mhruslan simulationanalysisofthefourconfigurationsofsolardesiccantcoolingsystemusingevaporativecoolingintropicalweatherinmalaysia |