Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects

Background. The leading role in long-term survival of the prosthesis installed using impaction bone grafting is given to the mechanical properties of the graft. The aim of the study is to explore the mechanical properties of osteoplastic material and determine the potential impact of cyclic loads...

Full description

Saved in:
Bibliographic Details
Main Authors: Vadim N. Golnik, Natalia V. Fedorova, Alexey Y. Larichkin, Svetlana V. Boyko, Andrey A. Panchenko, Alexandr M. Kosinov, Vladimir A. Peleganchuk, Vitaliy V. Pavlov
Format: Article
Language:Russian
Published: Vreden Russian Research Institute of Traumatology and Orthopedics 2024-12-01
Series:Travmatologiâ i Ortopediâ Rossii
Subjects:
Online Access:https://journal.rniito.org/jour/article/viewFile/17564/pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832594233001771008
author Vadim N. Golnik
Natalia V. Fedorova
Alexey Y. Larichkin
Svetlana V. Boyko
Andrey A. Panchenko
Alexandr M. Kosinov
Vladimir A. Peleganchuk
Vitaliy V. Pavlov
author_facet Vadim N. Golnik
Natalia V. Fedorova
Alexey Y. Larichkin
Svetlana V. Boyko
Andrey A. Panchenko
Alexandr M. Kosinov
Vladimir A. Peleganchuk
Vitaliy V. Pavlov
author_sort Vadim N. Golnik
collection DOAJ
description Background. The leading role in long-term survival of the prosthesis installed using impaction bone grafting is given to the mechanical properties of the graft. The aim of the study is to explore the mechanical properties of osteoplastic material and determine the potential impact of cyclic loads on dynamic changes in the position of the acetabular component after revision hip arthroplasty using impaction bone grafting. Methods. We conducted an experiment evaluating the impact of cyclic loads on the mechanical properties of osteoplastic material. At the first stage, a single-cycle tension-compression testing was carried out. Cyclic tests were carried out at the second stage of the experiment. Taking into account the presence of blood in the wound, we provided for a model with an aqueous solution of 45% glycerin. Clinical interpretation of biomechanics was carried out basing on the dynamic radiography data of two patients who underwent revision hip arthroplasty with the use of impaction bone grafting (IBG). The changes in the position of the rotation center and acetabular component were assessed. Results. During a single-cycle loading, we observed stress-strain dependences and instantaneous elastic moduli for each specimen. During cyclic tests, we obtained the increase of the instantaneous elastic modulus by 2.6 times for a “dry” specimen and from 3.9 to 4.7 times for the ones with liquid. X-rays of both patients showed the shift of the center rotation cranially and laterally: 2.4 and 1.5 mm in the first case and 14.9 and 9.5 mm in the second one, respectively. In the first case the change in the inclination was 18.7º, in the second case — 19.8º. The Hip Harris Score (HHS) was 97 points for the first patient, 53 points — for the second one. Conclusions. The material used for IBG is subject to deformation both in the intraoperative and postoperative period. Compression tests have suggested that the deformation of morselized impacted bone graft gradually tends to reach a plateau in the postoperative period, and with the completion of the deformation, migration of the acetabular component stops. The change in the position of the rotation center and acetabular component in the absence of a radiolucent line is not an absolute sign of loosening.
format Article
id doaj-art-ac29adb1631147af85ed604a48e6c911
institution Kabale University
issn 2311-2905
2542-0933
language Russian
publishDate 2024-12-01
publisher Vreden Russian Research Institute of Traumatology and Orthopedics
record_format Article
series Travmatologiâ i Ortopediâ Rossii
spelling doaj-art-ac29adb1631147af85ed604a48e6c9112025-01-20T02:43:24ZrusVreden Russian Research Institute of Traumatology and OrthopedicsTravmatologiâ i Ortopediâ Rossii2311-29052542-09332024-12-0130410111310.17816/2311-2905-175641363Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspectsVadim N. Golnik0https://orcid.org/0000-0002-5047-2060Natalia V. Fedorova1https://orcid.org/0000-0002-6850-995XAlexey Y. Larichkin2https://orcid.org/0000-0002-7306-9522Svetlana V. Boyko3https://orcid.org/0000-0002-1478-0533Andrey A. Panchenko4https://orcid.org/0000-0002-1018-5059Alexandr M. Kosinov5https://orcid.org/0009-0004-8973-172XVladimir A. Peleganchuk6https://orcid.org/0000-0002-2386-4421Vitaliy V. Pavlov7https://orcid.org/0000-0002-8997-7330Federal Center of Traumatology, Orthopedics and ArthroplastyLavrentyev Institute of Hydrodynamics SB RASLavrentyev Institute of Hydrodynamics SB RASLavrentyev Institute of Hydrodynamics SB RASLOGEEKS MS LLCLavrentyev Institute of Hydrodynamics SB RASFederal Center of Traumatology, Orthopedics and ArthroplastyNovosibirsk Research Institute of Traumatology and Orthopedics n.a. Ya.L. TsivyanBackground. The leading role in long-term survival of the prosthesis installed using impaction bone grafting is given to the mechanical properties of the graft. The aim of the study is to explore the mechanical properties of osteoplastic material and determine the potential impact of cyclic loads on dynamic changes in the position of the acetabular component after revision hip arthroplasty using impaction bone grafting. Methods. We conducted an experiment evaluating the impact of cyclic loads on the mechanical properties of osteoplastic material. At the first stage, a single-cycle tension-compression testing was carried out. Cyclic tests were carried out at the second stage of the experiment. Taking into account the presence of blood in the wound, we provided for a model with an aqueous solution of 45% glycerin. Clinical interpretation of biomechanics was carried out basing on the dynamic radiography data of two patients who underwent revision hip arthroplasty with the use of impaction bone grafting (IBG). The changes in the position of the rotation center and acetabular component were assessed. Results. During a single-cycle loading, we observed stress-strain dependences and instantaneous elastic moduli for each specimen. During cyclic tests, we obtained the increase of the instantaneous elastic modulus by 2.6 times for a “dry” specimen and from 3.9 to 4.7 times for the ones with liquid. X-rays of both patients showed the shift of the center rotation cranially and laterally: 2.4 and 1.5 mm in the first case and 14.9 and 9.5 mm in the second one, respectively. In the first case the change in the inclination was 18.7º, in the second case — 19.8º. The Hip Harris Score (HHS) was 97 points for the first patient, 53 points — for the second one. Conclusions. The material used for IBG is subject to deformation both in the intraoperative and postoperative period. Compression tests have suggested that the deformation of morselized impacted bone graft gradually tends to reach a plateau in the postoperative period, and with the completion of the deformation, migration of the acetabular component stops. The change in the position of the rotation center and acetabular component in the absence of a radiolucent line is not an absolute sign of loosening.https://journal.rniito.org/jour/article/viewFile/17564/pdfbiomechanicscyclic loadsimpact bone graftingbone defectgraftrevision arthroplasty
spellingShingle Vadim N. Golnik
Natalia V. Fedorova
Alexey Y. Larichkin
Svetlana V. Boyko
Andrey A. Panchenko
Alexandr M. Kosinov
Vladimir A. Peleganchuk
Vitaliy V. Pavlov
Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects
Travmatologiâ i Ortopediâ Rossii
biomechanics
cyclic loads
impact bone grafting
bone defect
graft
revision arthroplasty
title Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects
title_full Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects
title_fullStr Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects
title_full_unstemmed Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects
title_short Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects
title_sort impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty biomechanical aspects
topic biomechanics
cyclic loads
impact bone grafting
bone defect
graft
revision arthroplasty
url https://journal.rniito.org/jour/article/viewFile/17564/pdf
work_keys_str_mv AT vadimngolnik impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects
AT nataliavfedorova impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects
AT alexeyylarichkin impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects
AT svetlanavboyko impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects
AT andreyapanchenko impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects
AT alexandrmkosinov impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects
AT vladimirapeleganchuk impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects
AT vitaliyvpavlov impactionbonegraftingforacetabularbonedefectsreplacementinrevisionhiparthroplastybiomechanicalaspects