Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System

The operation of accelerator-driven systems or spallation sources requires the monitoring of intense neutron fluxes, which may be billions-fold more intense than the fluxes obtained with usual radioactive sources. If a neutron detector is placed near a very intense source, it can become saturated be...

Full description

Saved in:
Bibliographic Details
Main Authors: V. Bécares, J. Blázquez
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2012/240693
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832567538816385024
author V. Bécares
J. Blázquez
author_facet V. Bécares
J. Blázquez
author_sort V. Bécares
collection DOAJ
description The operation of accelerator-driven systems or spallation sources requires the monitoring of intense neutron fluxes, which may be billions-fold more intense than the fluxes obtained with usual radioactive sources. If a neutron detector is placed near a very intense source, it can become saturated because of detector dead time. On the contrary, if it is placed far away from the source, it will lose counting statistics. For this reason, there must exist an optimal position for placing the detector. The optimal position is defined as the one with the minimal relative uncertainty in the counting rate. In this work, we review the techniques to determine the detector dead time that can be applied with an accelerator-driven subcritical system or a spallation source. For the case of a spallation source, counting rates do not follow Poisson's statistics because of the multiplicity of the number of neutrons emitted by incident proton. It has been found a simple expression that relates the optimal counting rate with the source multiplicity and the uncertainty in the determination of the dead time.
format Article
id doaj-art-a95882fc0028431bb8f591019084c995
institution Kabale University
issn 1687-6075
1687-6083
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series Science and Technology of Nuclear Installations
spelling doaj-art-a95882fc0028431bb8f591019084c9952025-02-03T01:01:17ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832012-01-01201210.1155/2012/240693240693Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying SystemV. Bécares0J. Blázquez1Division of Nuclear Fission, CIEMAT, Avenida Complutense 40, 28040 Madrid, SpainDivision of Nuclear Fission, CIEMAT, Avenida Complutense 40, 28040 Madrid, SpainThe operation of accelerator-driven systems or spallation sources requires the monitoring of intense neutron fluxes, which may be billions-fold more intense than the fluxes obtained with usual radioactive sources. If a neutron detector is placed near a very intense source, it can become saturated because of detector dead time. On the contrary, if it is placed far away from the source, it will lose counting statistics. For this reason, there must exist an optimal position for placing the detector. The optimal position is defined as the one with the minimal relative uncertainty in the counting rate. In this work, we review the techniques to determine the detector dead time that can be applied with an accelerator-driven subcritical system or a spallation source. For the case of a spallation source, counting rates do not follow Poisson's statistics because of the multiplicity of the number of neutrons emitted by incident proton. It has been found a simple expression that relates the optimal counting rate with the source multiplicity and the uncertainty in the determination of the dead time.http://dx.doi.org/10.1155/2012/240693
spellingShingle V. Bécares
J. Blázquez
Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System
Science and Technology of Nuclear Installations
title Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System
title_full Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System
title_fullStr Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System
title_full_unstemmed Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System
title_short Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System
title_sort detector dead time determination and optimal counting rate for a detector near a spallation source or a subcritical multiplying system
url http://dx.doi.org/10.1155/2012/240693
work_keys_str_mv AT vbecares detectordeadtimedeterminationandoptimalcountingrateforadetectornearaspallationsourceorasubcriticalmultiplyingsystem
AT jblazquez detectordeadtimedeterminationandoptimalcountingrateforadetectornearaspallationsourceorasubcriticalmultiplyingsystem