Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig Bone
Correctly torquing bone screws is important to achieve good patient outcomes. An automated system has been previously proposed that may allow more objective torquing of bone screws. Here the system is tested vs. a static torque limit in pig bone. 5 screws were first inserted until stripping to calib...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
De Gruyter
2024-09-01
|
Series: | Current Directions in Biomedical Engineering |
Subjects: | |
Online Access: | https://doi.org/10.1515/cdbme-2024-1071 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832570519233232896 |
---|---|
author | Wilkie Jack Richard Jordan Joshi Aditya McFarlane Zoe Staiger Mark Rauter Georg Möller Knut |
author_facet | Wilkie Jack Richard Jordan Joshi Aditya McFarlane Zoe Staiger Mark Rauter Georg Möller Knut |
author_sort | Wilkie Jack |
collection | DOAJ |
description | Correctly torquing bone screws is important to achieve good patient outcomes. An automated system has been previously proposed that may allow more objective torquing of bone screws. Here the system is tested vs. a static torque limit in pig bone. 5 screws were first inserted until stripping to calibrate the dynamic and static limits. Then 6 were inserted limited to 80% of the mean stripping torque. Then 7 were inserted using 80% of the dynamic model-predicted stripping torque. The pull-out strength of the dynamic and static insertions were compared and no statistically significant difference was found. Future work should consider at using larger screws and different bone samples, with more repetitions to try and obtain a statistically significant result. |
format | Article |
id | doaj-art-a8cc8c1da5f049ea834005fcd4012d77 |
institution | Kabale University |
issn | 2364-5504 |
language | English |
publishDate | 2024-09-01 |
publisher | De Gruyter |
record_format | Article |
series | Current Directions in Biomedical Engineering |
spelling | doaj-art-a8cc8c1da5f049ea834005fcd4012d772025-02-02T15:45:00ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042024-09-01102757810.1515/cdbme-2024-1071Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig BoneWilkie Jack0Richard Jordan1Joshi Aditya2McFarlane Zoe3Staiger Mark4Rauter Georg5Möller Knut6ITeM, HS-Furtwangen, VS-Schwenningen, Furtwangen, GermanyDepartment of Mechanical Engineering, University of Canterbury,Christchurch, New ZealandDepartment of Mechanical Engineering, University of Canterbury,Christchurch, New ZealandDepartment of Mechanical Engineering, University of Canterbury,Christchurch, New ZealandDepartment of Mechanical Engineering, University of Canterbury,Christchurch, New ZealandBIROMED-Lab, University of Basel,Basel, SwitzerlandITeM, HS-Furtwangen, VS-Schwenningen, Furtwangen, GermanyCorrectly torquing bone screws is important to achieve good patient outcomes. An automated system has been previously proposed that may allow more objective torquing of bone screws. Here the system is tested vs. a static torque limit in pig bone. 5 screws were first inserted until stripping to calibrate the dynamic and static limits. Then 6 were inserted limited to 80% of the mean stripping torque. Then 7 were inserted using 80% of the dynamic model-predicted stripping torque. The pull-out strength of the dynamic and static insertions were compared and no statistically significant difference was found. Future work should consider at using larger screws and different bone samples, with more repetitions to try and obtain a statistically significant result.https://doi.org/10.1515/cdbme-2024-1071bone screwsmart screwdriverparameter identificationautomaticpig bone |
spellingShingle | Wilkie Jack Richard Jordan Joshi Aditya McFarlane Zoe Staiger Mark Rauter Georg Möller Knut Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig Bone Current Directions in Biomedical Engineering bone screw smart screwdriver parameter identification automatic pig bone |
title | Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig Bone |
title_full | Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig Bone |
title_fullStr | Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig Bone |
title_full_unstemmed | Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig Bone |
title_short | Dynamic Torque Limitation vs Static Torque Limitation for Bone Screws in Pig Bone |
title_sort | dynamic torque limitation vs static torque limitation for bone screws in pig bone |
topic | bone screw smart screwdriver parameter identification automatic pig bone |
url | https://doi.org/10.1515/cdbme-2024-1071 |
work_keys_str_mv | AT wilkiejack dynamictorquelimitationvsstatictorquelimitationforbonescrewsinpigbone AT richardjordan dynamictorquelimitationvsstatictorquelimitationforbonescrewsinpigbone AT joshiaditya dynamictorquelimitationvsstatictorquelimitationforbonescrewsinpigbone AT mcfarlanezoe dynamictorquelimitationvsstatictorquelimitationforbonescrewsinpigbone AT staigermark dynamictorquelimitationvsstatictorquelimitationforbonescrewsinpigbone AT rautergeorg dynamictorquelimitationvsstatictorquelimitationforbonescrewsinpigbone AT mollerknut dynamictorquelimitationvsstatictorquelimitationforbonescrewsinpigbone |