Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink

As the harmonic pollution of power grid is becoming increasingly seriously, harmonic and reactive detection has became one of the key approaches of power quality improvement. It analyzed amply a harmonic current detection method based on the two-dimensional spread theory and a fast harmonic detectio...

Full description

Saved in:
Bibliographic Details
Main Authors: 李圣清, 何政平, 李永安, 曾黎琳
Format: Article
Language:zho
Published: Editorial Office of Control and Information Technology 2012-01-01
Series:Kongzhi Yu Xinxi Jishu
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2012.06.015
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849224897438416896
author 李圣清
何政平
李永安
曾黎琳
author_facet 李圣清
何政平
李永安
曾黎琳
author_sort 李圣清
collection DOAJ
description As the harmonic pollution of power grid is becoming increasingly seriously, harmonic and reactive detection has became one of the key approaches of power quality improvement. It analyzed amply a harmonic current detection method based on the two-dimensional spread theory and a fast harmonic detection method based on the active current separation theory which has no phase locked loop (PLL), and verified them by Matlab/Simulink. Simulation results show that these two methods can detect harmonic and reactive currents of single-phase circuit real-timely and accurately under ideal conditions, and the algorithms are simple and easy to implement; but once the grid voltage distorts and the fundamental frequency offsets, the harmonic current detection algorithm of single-phase circuit based on the active current separation theory has a higher accuracy.
format Article
id doaj-art-a72d0ec13a0646e9b9b0aaba9b03badc
institution Kabale University
issn 2096-5427
language zho
publishDate 2012-01-01
publisher Editorial Office of Control and Information Technology
record_format Article
series Kongzhi Yu Xinxi Jishu
spelling doaj-art-a72d0ec13a0646e9b9b0aaba9b03badc2025-08-25T06:51:32ZzhoEditorial Office of Control and Information TechnologyKongzhi Yu Xinxi Jishu2096-54272012-01-0129545782333946Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink李圣清何政平李永安曾黎琳As the harmonic pollution of power grid is becoming increasingly seriously, harmonic and reactive detection has became one of the key approaches of power quality improvement. It analyzed amply a harmonic current detection method based on the two-dimensional spread theory and a fast harmonic detection method based on the active current separation theory which has no phase locked loop (PLL), and verified them by Matlab/Simulink. Simulation results show that these two methods can detect harmonic and reactive currents of single-phase circuit real-timely and accurately under ideal conditions, and the algorithms are simple and easy to implement; but once the grid voltage distorts and the fundamental frequency offsets, the harmonic current detection algorithm of single-phase circuit based on the active current separation theory has a higher accuracy.http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2012.06.015harmonic detectionactive power filteractive current separate methodtwo-dimensional spread theory
spellingShingle 李圣清
何政平
李永安
曾黎琳
Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink
Kongzhi Yu Xinxi Jishu
harmonic detection
active power filter
active current separate method
two-dimensional spread theory
title Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink
title_full Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink
title_fullStr Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink
title_full_unstemmed Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink
title_short Research on Two Detection Methods of Single-phase Circuit Harmonic Current Based on Simulink
title_sort research on two detection methods of single phase circuit harmonic current based on simulink
topic harmonic detection
active power filter
active current separate method
two-dimensional spread theory
url http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2012.06.015
work_keys_str_mv AT lǐshèngqīng researchontwodetectionmethodsofsinglephasecircuitharmoniccurrentbasedonsimulink
AT hézhèngpíng researchontwodetectionmethodsofsinglephasecircuitharmoniccurrentbasedonsimulink
AT lǐyǒngān researchontwodetectionmethodsofsinglephasecircuitharmoniccurrentbasedonsimulink
AT cénglílín researchontwodetectionmethodsofsinglephasecircuitharmoniccurrentbasedonsimulink