THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL

The results of experimental studies, the purpose of which was to study the effect of low-intensity pulsed ultrasound on the wettability of the surface of titanium dental implants are described. We studied 64 titanium dental implants. The control group consisted of 32 dental implants without ultra-so...

Full description

Saved in:
Bibliographic Details
Main Authors: S. P. Rubnikovich, I. S. Khomich, V. T. Minchenya
Format: Article
Language:Russian
Published: Educational institution «Belarusian State University of Informatics and Radioelectronics» 2019-06-01
Series:Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
Subjects:
Online Access:https://doklady.bsuir.by/jour/article/view/763
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849340401916313600
author S. P. Rubnikovich
I. S. Khomich
V. T. Minchenya
author_facet S. P. Rubnikovich
I. S. Khomich
V. T. Minchenya
author_sort S. P. Rubnikovich
collection DOAJ
description The results of experimental studies, the purpose of which was to study the effect of low-intensity pulsed ultrasound on the wettability of the surface of titanium dental implants are described. We studied 64 titanium dental implants. The control group consisted of 32 dental implants without ultra-sonication. The experimental group consisted of 32 dental implants, which were exposed to low-intensity pulsed ultrasound. Studies using low-intensity pulsed ultrasound showed that the wettability of the surface of all the experimental samples (32 dental implant) was 100 %, and the wettability of control samples (32 dental implant) was not observed. Thus the previously unknown property of low intensity pulsed ultrasound enabling the wetting of entire surface of the dental implant was discovered.
format Article
id doaj-art-a6f1b94c672943928db15f3598a33e28
institution Kabale University
issn 1729-7648
language Russian
publishDate 2019-06-01
publisher Educational institution «Belarusian State University of Informatics and Radioelectronics»
record_format Article
series Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
spelling doaj-art-a6f1b94c672943928db15f3598a33e282025-08-20T03:43:55ZrusEducational institution «Belarusian State University of Informatics and Radioelectronics»Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki1729-76482019-06-010720132017762THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODELS. P. Rubnikovich0I. S. Khomich1V. T. Minchenya2Белорусская медицинская академия последипломного образованияБелорусская медицинская академия последипломного образованияБелорусский национальный технический университетThe results of experimental studies, the purpose of which was to study the effect of low-intensity pulsed ultrasound on the wettability of the surface of titanium dental implants are described. We studied 64 titanium dental implants. The control group consisted of 32 dental implants without ultra-sonication. The experimental group consisted of 32 dental implants, which were exposed to low-intensity pulsed ultrasound. Studies using low-intensity pulsed ultrasound showed that the wettability of the surface of all the experimental samples (32 dental implant) was 100 %, and the wettability of control samples (32 dental implant) was not observed. Thus the previously unknown property of low intensity pulsed ultrasound enabling the wetting of entire surface of the dental implant was discovered.https://doklady.bsuir.by/jour/article/view/763low intensity pulsed ultrasoundsurface wettabilityosseointegrationdental implantsdental implantology
spellingShingle S. P. Rubnikovich
I. S. Khomich
V. T. Minchenya
THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL
Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki
low intensity pulsed ultrasound
surface wettability
osseointegration
dental implants
dental implantology
title THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL
title_full THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL
title_fullStr THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL
title_full_unstemmed THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL
title_short THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL
title_sort study of low intensity pulsed ultrasound influence on wettability of titanium dental implants surface in experimental model
topic low intensity pulsed ultrasound
surface wettability
osseointegration
dental implants
dental implantology
url https://doklady.bsuir.by/jour/article/view/763
work_keys_str_mv AT sprubnikovich thestudyoflowintensitypulsedultrasoundinfluenceonwettabilityoftitaniumdentalimplantssurfaceinexperimentalmodel
AT iskhomich thestudyoflowintensitypulsedultrasoundinfluenceonwettabilityoftitaniumdentalimplantssurfaceinexperimentalmodel
AT vtminchenya thestudyoflowintensitypulsedultrasoundinfluenceonwettabilityoftitaniumdentalimplantssurfaceinexperimentalmodel
AT sprubnikovich studyoflowintensitypulsedultrasoundinfluenceonwettabilityoftitaniumdentalimplantssurfaceinexperimentalmodel
AT iskhomich studyoflowintensitypulsedultrasoundinfluenceonwettabilityoftitaniumdentalimplantssurfaceinexperimentalmodel
AT vtminchenya studyoflowintensitypulsedultrasoundinfluenceonwettabilityoftitaniumdentalimplantssurfaceinexperimentalmodel