Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment

Measurement of partial discharges (PD) is a generally accepted method of diagnosing the insulation of electrical equipment worldwide. Today, the trend is to move from conventional offline testing to online monitoring to predict the service life of insulation. For testing and calibration of the...

Full description

Saved in:
Bibliographic Details
Main Authors: T. G. Galieva, D. A. Ivanov, M. F. Sadykov, A. V. Golenishchev-Kutuzov
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2021-11-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%205%20(179)%20(%D0%9E%D0%9D%D0%92)/80-87%20%D0%93%D0%B0%D0%BB%D0%B8%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%93.,%20%D0%98%D0%B2%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A1%D0%B0%D0%B4%D1%8B%D0%BA%D0%BE%D0%B2%20%D0%9C.%20%D0%A4.,%20%D0%93%D0%BE%D0%BB%D0%B5%D0%BD%D0%B8%D1%89%D0%B5%D0%B2-.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832572429471318016
author T. G. Galieva
D. A. Ivanov
M. F. Sadykov
A. V. Golenishchev-Kutuzov
author_facet T. G. Galieva
D. A. Ivanov
M. F. Sadykov
A. V. Golenishchev-Kutuzov
author_sort T. G. Galieva
collection DOAJ
description Measurement of partial discharges (PD) is a generally accepted method of diagnosing the insulation of electrical equipment worldwide. Today, the trend is to move from conventional offline testing to online monitoring to predict the service life of insulation. For testing and calibration of the developed new methods with the contact method, a laboratory stand has been developed in accordance with GOST R 55191-2012 (IEC 60270:2000). The article suggests the use of acoustic and electromagnetic methods for a system of continuous non-contact non-destructive testing of the technical condition of insulation equipment, which will allow monitoring insulation equipment online and predicting its residual life. On their basis, a system of «on-line» diagnostics of high-voltage insulators has been developed.
format Article
id doaj-art-a6d9cca1bb4b49e08f6942f969009437
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2021-11-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-a6d9cca1bb4b49e08f6942f9690094372025-02-02T10:00:56ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412021-11-015 (179)808710.25206/1813-8225-2021-179-80-87Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipmentT. G. Galieva0D. A. Ivanov1M. F. Sadykov2A. V. Golenishchev-Kutuzov3Kazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityMeasurement of partial discharges (PD) is a generally accepted method of diagnosing the insulation of electrical equipment worldwide. Today, the trend is to move from conventional offline testing to online monitoring to predict the service life of insulation. For testing and calibration of the developed new methods with the contact method, a laboratory stand has been developed in accordance with GOST R 55191-2012 (IEC 60270:2000). The article suggests the use of acoustic and electromagnetic methods for a system of continuous non-contact non-destructive testing of the technical condition of insulation equipment, which will allow monitoring insulation equipment online and predicting its residual life. On their basis, a system of «on-line» diagnostics of high-voltage insulators has been developed.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%205%20(179)%20(%D0%9E%D0%9D%D0%92)/80-87%20%D0%93%D0%B0%D0%BB%D0%B8%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%93.,%20%D0%98%D0%B2%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A1%D0%B0%D0%B4%D1%8B%D0%BA%D0%BE%D0%B2%20%D0%9C.%20%D0%A4.,%20%D0%93%D0%BE%D0%BB%D0%B5%D0%BD%D0%B8%D1%89%D0%B5%D0%B2-.pdfpartial dischargediagnostics of insulation equipmentlaboratory standelectromagnetic methodcontact methodultrasonic method
spellingShingle T. G. Galieva
D. A. Ivanov
M. F. Sadykov
A. V. Golenishchev-Kutuzov
Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment
Омский научный вестник
partial discharge
diagnostics of insulation equipment
laboratory stand
electromagnetic method
contact method
ultrasonic method
title Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment
title_full Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment
title_fullStr Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment
title_full_unstemmed Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment
title_short Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment
title_sort laboratory stand for development of method and system for continuous non contact non destructive testing of technical condition of insulation equipment
topic partial discharge
diagnostics of insulation equipment
laboratory stand
electromagnetic method
contact method
ultrasonic method
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%205%20(179)%20(%D0%9E%D0%9D%D0%92)/80-87%20%D0%93%D0%B0%D0%BB%D0%B8%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%93.,%20%D0%98%D0%B2%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A1%D0%B0%D0%B4%D1%8B%D0%BA%D0%BE%D0%B2%20%D0%9C.%20%D0%A4.,%20%D0%93%D0%BE%D0%BB%D0%B5%D0%BD%D0%B8%D1%89%D0%B5%D0%B2-.pdf
work_keys_str_mv AT tggalieva laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment
AT daivanov laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment
AT mfsadykov laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment
AT avgolenishchevkutuzov laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment