Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment
Measurement of partial discharges (PD) is a generally accepted method of diagnosing the insulation of electrical equipment worldwide. Today, the trend is to move from conventional offline testing to online monitoring to predict the service life of insulation. For testing and calibration of the...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2021-11-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%205%20(179)%20(%D0%9E%D0%9D%D0%92)/80-87%20%D0%93%D0%B0%D0%BB%D0%B8%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%93.,%20%D0%98%D0%B2%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A1%D0%B0%D0%B4%D1%8B%D0%BA%D0%BE%D0%B2%20%D0%9C.%20%D0%A4.,%20%D0%93%D0%BE%D0%BB%D0%B5%D0%BD%D0%B8%D1%89%D0%B5%D0%B2-.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832572429471318016 |
---|---|
author | T. G. Galieva D. A. Ivanov M. F. Sadykov A. V. Golenishchev-Kutuzov |
author_facet | T. G. Galieva D. A. Ivanov M. F. Sadykov A. V. Golenishchev-Kutuzov |
author_sort | T. G. Galieva |
collection | DOAJ |
description | Measurement of partial discharges (PD) is a generally
accepted method of diagnosing the insulation of electrical
equipment worldwide. Today, the trend is to move from
conventional offline testing to online monitoring to predict
the service life of insulation. For testing and calibration of
the developed new methods with the contact method, a
laboratory stand has been developed in accordance with
GOST R 55191-2012 (IEC 60270:2000). The article suggests
the use of acoustic and electromagnetic methods for a
system of continuous non-contact non-destructive testing
of the technical condition of insulation equipment, which
will allow monitoring insulation equipment online and
predicting its residual life. On their basis, a system of
«on-line» diagnostics of high-voltage insulators has been
developed. |
format | Article |
id | doaj-art-a6d9cca1bb4b49e08f6942f969009437 |
institution | Kabale University |
issn | 1813-8225 2541-7541 |
language | English |
publishDate | 2021-11-01 |
publisher | Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education |
record_format | Article |
series | Омский научный вестник |
spelling | doaj-art-a6d9cca1bb4b49e08f6942f9690094372025-02-02T10:00:56ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412021-11-015 (179)808710.25206/1813-8225-2021-179-80-87Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipmentT. G. Galieva0D. A. Ivanov1M. F. Sadykov2A. V. Golenishchev-Kutuzov3Kazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityMeasurement of partial discharges (PD) is a generally accepted method of diagnosing the insulation of electrical equipment worldwide. Today, the trend is to move from conventional offline testing to online monitoring to predict the service life of insulation. For testing and calibration of the developed new methods with the contact method, a laboratory stand has been developed in accordance with GOST R 55191-2012 (IEC 60270:2000). The article suggests the use of acoustic and electromagnetic methods for a system of continuous non-contact non-destructive testing of the technical condition of insulation equipment, which will allow monitoring insulation equipment online and predicting its residual life. On their basis, a system of «on-line» diagnostics of high-voltage insulators has been developed.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%205%20(179)%20(%D0%9E%D0%9D%D0%92)/80-87%20%D0%93%D0%B0%D0%BB%D0%B8%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%93.,%20%D0%98%D0%B2%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A1%D0%B0%D0%B4%D1%8B%D0%BA%D0%BE%D0%B2%20%D0%9C.%20%D0%A4.,%20%D0%93%D0%BE%D0%BB%D0%B5%D0%BD%D0%B8%D1%89%D0%B5%D0%B2-.pdfpartial dischargediagnostics of insulation equipmentlaboratory standelectromagnetic methodcontact methodultrasonic method |
spellingShingle | T. G. Galieva D. A. Ivanov M. F. Sadykov A. V. Golenishchev-Kutuzov Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment Омский научный вестник partial discharge diagnostics of insulation equipment laboratory stand electromagnetic method contact method ultrasonic method |
title | Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment |
title_full | Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment |
title_fullStr | Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment |
title_full_unstemmed | Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment |
title_short | Laboratory stand for development of method and system for continuous non-contact non-destructive testing of technical condition of insulation equipment |
title_sort | laboratory stand for development of method and system for continuous non contact non destructive testing of technical condition of insulation equipment |
topic | partial discharge diagnostics of insulation equipment laboratory stand electromagnetic method contact method ultrasonic method |
url | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2021/%E2%84%96%205%20(179)%20(%D0%9E%D0%9D%D0%92)/80-87%20%D0%93%D0%B0%D0%BB%D0%B8%D0%B5%D0%B2%D0%B0%20%D0%A2.%20%D0%93.,%20%D0%98%D0%B2%D0%B0%D0%BD%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A1%D0%B0%D0%B4%D1%8B%D0%BA%D0%BE%D0%B2%20%D0%9C.%20%D0%A4.,%20%D0%93%D0%BE%D0%BB%D0%B5%D0%BD%D0%B8%D1%89%D0%B5%D0%B2-.pdf |
work_keys_str_mv | AT tggalieva laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment AT daivanov laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment AT mfsadykov laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment AT avgolenishchevkutuzov laboratorystandfordevelopmentofmethodandsystemforcontinuousnoncontactnondestructivetestingoftechnicalconditionofinsulationequipment |