A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System
This paper presents a new systematic approach to analyze all possible array configurations in order to determine the most optimal dense-array configuration for concentrator photovoltaic (CPV) systems. The proposed method is fast, simple, reasonably accurate, and very useful as a preliminary study be...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2013-01-01
|
Series: | The Scientific World Journal |
Online Access: | http://dx.doi.org/10.1155/2013/275169 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832568307651182592 |
---|---|
author | Fei-Lu Siaw Kok-Keong Chong |
author_facet | Fei-Lu Siaw Kok-Keong Chong |
author_sort | Fei-Lu Siaw |
collection | DOAJ |
description | This paper presents a new systematic approach to analyze all possible array configurations in order to determine the most optimal dense-array configuration for concentrator photovoltaic (CPV) systems. The proposed method is fast, simple, reasonably accurate, and very useful as a preliminary study before constructing a dense-array CPV panel. Using measured flux distribution data, each CPV cells’ voltage and current values at three critical points which are at short-circuit, open-circuit, and maximum power point are determined. From there, an algorithm groups the cells into basic modules. The next step is I-V curve prediction, to find the maximum output power of each array configuration. As a case study, twenty different I-V predictions are made for a prototype of nonimaging planar concentrator, and the array configuration that yields the highest output power is determined. The result is then verified by assembling and testing of an actual dense-array on the prototype. It was found that the I-V curve closely resembles simulated I-V prediction, and measured maximum output power varies by only 1.34%. |
format | Article |
id | doaj-art-a6069cc8f7a04b189ebb0cd1b25771cd |
institution | Kabale University |
issn | 1537-744X |
language | English |
publishDate | 2013-01-01 |
publisher | Wiley |
record_format | Article |
series | The Scientific World Journal |
spelling | doaj-art-a6069cc8f7a04b189ebb0cd1b25771cd2025-02-03T00:59:24ZengWileyThe Scientific World Journal1537-744X2013-01-01201310.1155/2013/275169275169A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic SystemFei-Lu Siaw0Kok-Keong Chong1Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Off Jalan Genting Kelang Setapak, 53300 Kuala Lumpur, MalaysiaFaculty of Engineering and Science, Universiti Tunku Abdul Rahman, Off Jalan Genting Kelang Setapak, 53300 Kuala Lumpur, MalaysiaThis paper presents a new systematic approach to analyze all possible array configurations in order to determine the most optimal dense-array configuration for concentrator photovoltaic (CPV) systems. The proposed method is fast, simple, reasonably accurate, and very useful as a preliminary study before constructing a dense-array CPV panel. Using measured flux distribution data, each CPV cells’ voltage and current values at three critical points which are at short-circuit, open-circuit, and maximum power point are determined. From there, an algorithm groups the cells into basic modules. The next step is I-V curve prediction, to find the maximum output power of each array configuration. As a case study, twenty different I-V predictions are made for a prototype of nonimaging planar concentrator, and the array configuration that yields the highest output power is determined. The result is then verified by assembling and testing of an actual dense-array on the prototype. It was found that the I-V curve closely resembles simulated I-V prediction, and measured maximum output power varies by only 1.34%.http://dx.doi.org/10.1155/2013/275169 |
spellingShingle | Fei-Lu Siaw Kok-Keong Chong A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System The Scientific World Journal |
title | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_full | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_fullStr | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_full_unstemmed | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_short | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_sort | systematic method of interconnection optimization for dense array concentrator photovoltaic system |
url | http://dx.doi.org/10.1155/2013/275169 |
work_keys_str_mv | AT feilusiaw asystematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem AT kokkeongchong asystematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem AT feilusiaw systematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem AT kokkeongchong systematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem |