KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR
Abstract Drinking water worth consumption are those that should be odorless, tasteless, clean, the temperatures preferably below air temperature, and low amounts of dissolved solids. On this turbidity and total dissolved solid water system is required some sensor devices. The accuracy of the sens...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Universitas Negeri Jakarta
2017-10-01
|
| Series: | Spektra: Jurnal Fisika dan Aplikasinya |
| Subjects: | |
| Online Access: | https://journal.unj.ac.id/unj/index.php/spektra/article/view/3981 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849698144596525056 |
|---|---|
| author | Zulfiah Ayu Kurnia Sari Handjoko Permana Widyaningrum Indrasari |
| author_facet | Zulfiah Ayu Kurnia Sari Handjoko Permana Widyaningrum Indrasari |
| author_sort | Zulfiah Ayu Kurnia Sari |
| collection | DOAJ |
| description | Abstract
Drinking water worth consumption are those that should be odorless, tasteless, clean, the temperatures preferably below air temperature, and low amounts of dissolved solids. On this turbidity and total dissolved solid water system is required some sensor devices. The accuracy of the sensor is an important thing to support the effectiveness of the system. In this research, the calibration of ds18b20 sensor as temperature detector, photodiode sensor as turbidity detector, and conductivity sensor as a detector of dissolved solid (TDS) in water and using Arduino as a microcontroller. The characterization is done by comparing the sensor output with laboratory test equipment. The result of characterization means that each measurement sensor has a variation error that is photodiode sensor with relative error 3.13%, sensor ds18b20 1.77%, and conductivity sensor 2.42%.
Keywords: temperature, turbidity, TDS, Arduino. |
| format | Article |
| id | doaj-art-a4e40bc2021d45a0a26a1a093d3dce09 |
| institution | DOAJ |
| issn | 2541-3384 2541-3392 |
| language | English |
| publishDate | 2017-10-01 |
| publisher | Universitas Negeri Jakarta |
| record_format | Article |
| series | Spektra: Jurnal Fisika dan Aplikasinya |
| spelling | doaj-art-a4e40bc2021d45a0a26a1a093d3dce092025-08-20T03:18:59ZengUniversitas Negeri JakartaSpektra: Jurnal Fisika dan Aplikasinya2541-33842541-33922017-10-012214915610.21009/SPEKTRA.022.093023KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIRZulfiah Ayu Kurnia Sari0Handjoko Permana1Widyaningrum Indrasari2Universitas Negeri JakartaProgram Studi Fisika, FMIPA, Universitas Negeri Jakarta, Jl. Rawamangun Muka, Jakarta Timur 13220Prodi Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Negeri Jakarta, Jl. Rawamangun Muka No 1 , Jakarta 13220Abstract Drinking water worth consumption are those that should be odorless, tasteless, clean, the temperatures preferably below air temperature, and low amounts of dissolved solids. On this turbidity and total dissolved solid water system is required some sensor devices. The accuracy of the sensor is an important thing to support the effectiveness of the system. In this research, the calibration of ds18b20 sensor as temperature detector, photodiode sensor as turbidity detector, and conductivity sensor as a detector of dissolved solid (TDS) in water and using Arduino as a microcontroller. The characterization is done by comparing the sensor output with laboratory test equipment. The result of characterization means that each measurement sensor has a variation error that is photodiode sensor with relative error 3.13%, sensor ds18b20 1.77%, and conductivity sensor 2.42%. Keywords: temperature, turbidity, TDS, Arduino.https://journal.unj.ac.id/unj/index.php/spektra/article/view/3981temperatureturbiditytdsarduino uno |
| spellingShingle | Zulfiah Ayu Kurnia Sari Handjoko Permana Widyaningrum Indrasari KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR Spektra: Jurnal Fisika dan Aplikasinya temperature turbidity tds arduino uno |
| title | KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR |
| title_full | KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR |
| title_fullStr | KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR |
| title_full_unstemmed | KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR |
| title_short | KARAKTERISASI SENSOR PHOTODIODA, DS18B20, DAN KONDUKTIVITAS PADA RANCANG BANGUN SISTEM DETEKSI KEKERUHAN DAN JUMLAH ZAT PADAT TERLARUT DALAM AIR |
| title_sort | karakterisasi sensor photodioda ds18b20 dan konduktivitas pada rancang bangun sistem deteksi kekeruhan dan jumlah zat padat terlarut dalam air |
| topic | temperature turbidity tds arduino uno |
| url | https://journal.unj.ac.id/unj/index.php/spektra/article/view/3981 |
| work_keys_str_mv | AT zulfiahayukurniasari karakterisasisensorphotodiodads18b20dankonduktivitaspadarancangbangunsistemdeteksikekeruhandanjumlahzatpadatterlarutdalamair AT handjokopermana karakterisasisensorphotodiodads18b20dankonduktivitaspadarancangbangunsistemdeteksikekeruhandanjumlahzatpadatterlarutdalamair AT widyaningrumindrasari karakterisasisensorphotodiodads18b20dankonduktivitaspadarancangbangunsistemdeteksikekeruhandanjumlahzatpadatterlarutdalamair |