Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review

Background. Dorsal spanning plate fixation is an increasingly popular method of fixation for certain distal radius fractures. Published outcomes are encouraging, but complications are still reported. Methods. We present a case report of a 26-year-old woman with spanning plate breakage and extensor p...

Full description

Saved in:
Bibliographic Details
Main Authors: Rachel Lefebvre, Jessica Intravia, Lisa Cao, Alidad Ghiassi, Milan Stevanovic
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Case Reports in Orthopedics
Online Access:http://dx.doi.org/10.1155/2018/3256891
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832564349564092416
author Rachel Lefebvre
Jessica Intravia
Lisa Cao
Alidad Ghiassi
Milan Stevanovic
author_facet Rachel Lefebvre
Jessica Intravia
Lisa Cao
Alidad Ghiassi
Milan Stevanovic
author_sort Rachel Lefebvre
collection DOAJ
description Background. Dorsal spanning plate fixation is an increasingly popular method of fixation for certain distal radius fractures. Published outcomes are encouraging, but complications are still reported. Methods. We present a case report of a 26-year-old woman with spanning plate breakage and extensor pollicis longus (EPL) metallosis, fraying, and near-complete rupture. The patient’s unsuccessful follow-up led to this complication. Metallosis and damage to the extensor indices (EI) and distal extensor carpi radialis longus (ECRL) were intraoperative obstacles for tendon transfer to restore EPL function. Results. Tendon transfer in the setting of bridge plate failure has not yet been described in the literature. There are reports of spanning plate failure indicating that breakage often happens through the plate’s holes and after fracture healing. Conclusions. The compounded complication of plate failure with extensor tendon injury emphasizes the important relationship between the local anatomy, barriers to patient care, and potential problems after spanning plate fixation.
format Article
id doaj-art-a3e5f1e931ea4083b6bfe1befb5672ba
institution Kabale University
issn 2090-6749
2090-6757
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Case Reports in Orthopedics
spelling doaj-art-a3e5f1e931ea4083b6bfe1befb5672ba2025-02-03T01:11:15ZengWileyCase Reports in Orthopedics2090-67492090-67572018-01-01201810.1155/2018/32568913256891Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature ReviewRachel Lefebvre0Jessica Intravia1Lisa Cao2Alidad Ghiassi3Milan Stevanovic4Division of Hand Surgery, Department of Orthopaedic Surgery, University of Southern California, 1200 N State Street CT-A7D, Los Angeles 90033, USADivision of Hand Surgery, Department of Orthopaedic Surgery, University of Southern California, 1200 N State Street CT-A7D, Los Angeles 90033, USADivision of Hand Surgery, Department of Orthopaedic Surgery, University of Southern California, 1200 N State Street CT-A7D, Los Angeles 90033, USADivision of Hand Surgery, Department of Orthopaedic Surgery, University of Southern California, 1200 N State Street CT-A7D, Los Angeles 90033, USADivision of Hand Surgery, Department of Orthopaedic Surgery, University of Southern California, 1200 N State Street CT-A7D, Los Angeles 90033, USABackground. Dorsal spanning plate fixation is an increasingly popular method of fixation for certain distal radius fractures. Published outcomes are encouraging, but complications are still reported. Methods. We present a case report of a 26-year-old woman with spanning plate breakage and extensor pollicis longus (EPL) metallosis, fraying, and near-complete rupture. The patient’s unsuccessful follow-up led to this complication. Metallosis and damage to the extensor indices (EI) and distal extensor carpi radialis longus (ECRL) were intraoperative obstacles for tendon transfer to restore EPL function. Results. Tendon transfer in the setting of bridge plate failure has not yet been described in the literature. There are reports of spanning plate failure indicating that breakage often happens through the plate’s holes and after fracture healing. Conclusions. The compounded complication of plate failure with extensor tendon injury emphasizes the important relationship between the local anatomy, barriers to patient care, and potential problems after spanning plate fixation.http://dx.doi.org/10.1155/2018/3256891
spellingShingle Rachel Lefebvre
Jessica Intravia
Lisa Cao
Alidad Ghiassi
Milan Stevanovic
Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review
Case Reports in Orthopedics
title Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review
title_full Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review
title_fullStr Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review
title_full_unstemmed Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review
title_short Bridge Plate Failure with Extensor Tendon Injury: A Case Report and Literature Review
title_sort bridge plate failure with extensor tendon injury a case report and literature review
url http://dx.doi.org/10.1155/2018/3256891
work_keys_str_mv AT rachellefebvre bridgeplatefailurewithextensortendoninjuryacasereportandliteraturereview
AT jessicaintravia bridgeplatefailurewithextensortendoninjuryacasereportandliteraturereview
AT lisacao bridgeplatefailurewithextensortendoninjuryacasereportandliteraturereview
AT alidadghiassi bridgeplatefailurewithextensortendoninjuryacasereportandliteraturereview
AT milanstevanovic bridgeplatefailurewithextensortendoninjuryacasereportandliteraturereview