Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit

The research focuses on problems related to fouling of heat exchange equipment of DHT (diesel hydrotreatment) processes and heat exchanger condition diagnostics. The purpose of the work is to determine the critical parameters of operation of heat exchangers. According to the results of calculatio...

Full description

Saved in:
Bibliographic Details
Main Authors: A. М. Demin, A. P. Naumenko
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2019-10-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/4%20(166)/84-88%20%D0%94%D0%B5%D0%BC%D0%B8%D0%BD%20%D0%90.%20%D0%9C.,%20%D0%9D%D0%B0%D1%83%D0%BC%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%90.%20%D0%9F..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832572892451176448
author A. М. Demin
A. P. Naumenko
author_facet A. М. Demin
A. P. Naumenko
author_sort A. М. Demin
collection DOAJ
description The research focuses on problems related to fouling of heat exchange equipment of DHT (diesel hydrotreatment) processes and heat exchanger condition diagnostics. The purpose of the work is to determine the critical parameters of operation of heat exchangers. According to the results of calculations on a mathematical model of a typical hydrotreating unit using a real-time diagnostic program based on monitoring operational parameters, the criterion for assessing the state of the reactor unit heat exchanger increases from 1 to 1.37 with an increase in the annulus pollution coefficient. When this occurs, the temperature of the raw material at the exit of the apparatus decreases and the cost of additional fuel consumed by furnaces in the amount of more than 1 million rubles / month. Diagnosis of heat exchangers in real time allows you to optimize operating costs, including choosing the optimal time for cleaning tube bundles in terms of comparability of costs for additional fuel consumed and cleaning.
format Article
id doaj-art-a25cefb6d6c442ebaa754f191a75b292
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2019-10-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-a25cefb6d6c442ebaa754f191a75b2922025-02-02T06:24:03ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412019-10-014 (166)848810.25206/1813-8225-2019-166-84-88Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unitA. М. Demin0A. P. Naumenko1https://orcid.org/0000-0002-0583-7809Omsk State Technical UniversityOmsk State Technical UniversityThe research focuses on problems related to fouling of heat exchange equipment of DHT (diesel hydrotreatment) processes and heat exchanger condition diagnostics. The purpose of the work is to determine the critical parameters of operation of heat exchangers. According to the results of calculations on a mathematical model of a typical hydrotreating unit using a real-time diagnostic program based on monitoring operational parameters, the criterion for assessing the state of the reactor unit heat exchanger increases from 1 to 1.37 with an increase in the annulus pollution coefficient. When this occurs, the temperature of the raw material at the exit of the apparatus decreases and the cost of additional fuel consumed by furnaces in the amount of more than 1 million rubles / month. Diagnosis of heat exchangers in real time allows you to optimize operating costs, including choosing the optimal time for cleaning tube bundles in terms of comparability of costs for additional fuel consumed and cleaning.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/4%20(166)/84-88%20%D0%94%D0%B5%D0%BC%D0%B8%D0%BD%20%D0%90.%20%D0%9C.,%20%D0%9D%D0%B0%D1%83%D0%BC%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%90.%20%D0%9F..pdfcondition monitoringdiagnosticsheat exchange equipmentdiesel fuel hydrotreatingreal-time monitoringsign
spellingShingle A. М. Demin
A. P. Naumenko
Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit
Омский научный вестник
condition monitoring
diagnostics
heat exchange equipment
diesel fuel hydrotreating
real-time monitoring
sign
title Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit
title_full Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit
title_fullStr Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit
title_full_unstemmed Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit
title_short Diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit
title_sort diagnostics of heat exchange equipment on basis of operating parameters of diesel fuel hydrotreating unit
topic condition monitoring
diagnostics
heat exchange equipment
diesel fuel hydrotreating
real-time monitoring
sign
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/4%20(166)/84-88%20%D0%94%D0%B5%D0%BC%D0%B8%D0%BD%20%D0%90.%20%D0%9C.,%20%D0%9D%D0%B0%D1%83%D0%BC%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%90.%20%D0%9F..pdf
work_keys_str_mv AT amdemin diagnosticsofheatexchangeequipmentonbasisofoperatingparametersofdieselfuelhydrotreatingunit
AT apnaumenko diagnosticsofheatexchangeequipmentonbasisofoperatingparametersofdieselfuelhydrotreatingunit