Measuring Airtightness of High-Rise Buildings (Lessons Learned)

Measuring the airtightness of high-rise buildings presents significant challenges due to the effects of wind and thermal lift (stack effect). Small indoor/outdoor temperature differences, combined with the building’s height, can create substantial natural pressure differences on the building envelop...

Full description

Saved in:
Bibliographic Details
Main Authors: Stefanie Rolfsmeier, Emanuel Mairinger, Johannes Neubig, Thomas Gayer
Format: Article
Language:English
Published: MDPI AG 2025-02-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/15/5/724
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850050738320834560
author Stefanie Rolfsmeier
Emanuel Mairinger
Johannes Neubig
Thomas Gayer
author_facet Stefanie Rolfsmeier
Emanuel Mairinger
Johannes Neubig
Thomas Gayer
author_sort Stefanie Rolfsmeier
collection DOAJ
description Measuring the airtightness of high-rise buildings presents significant challenges due to the effects of wind and thermal lift (stack effect). Small indoor/outdoor temperature differences, combined with the building’s height, can create substantial natural pressure differences on the building envelope, while winds induce pressure fluctuations. The international standard ISO 9972 provides insufficient guidelines for dealing with these high and fluctuating natural pressure differences. In addition, it is crucial to achieve a uniform internal pressure distribution during the test. This paper discusses the airtightness testing of high-rise buildings up to 125 m tall using portable blower door devices, following the “airtightness measurement of high-rise buildings” Passive House guideline. Differential pressure sensors were placed on the ground and top floors to record the effects of wind and thermal lift, and additional sensors helped to achieve a uniform pressure distribution within the building. The readings from the ground and top floors ensured full depressurization and pressurization during testing. The setup of the measuring fans, mainly on the ground floor, was supplemented with additional fans on higher floors to maintain pressure uniformity within a 10% tolerance. To be able to conduct a multi-point regression test, it is recommended to limit the product of the indoor/outdoor temperature difference and building height to ≤1250 mK and to achieve a coefficient of determination of 0.98 or higher, a wind speed ≤ 3 Beaufort. The study concludes that an airtight building envelope and larger internal flow paths, such as stairwells and elevator shafts, simplify the measurement.
format Article
id doaj-art-a1b9e7b240cd4ce2bc0d93f50ab821fd
institution DOAJ
issn 2075-5309
language English
publishDate 2025-02-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj-art-a1b9e7b240cd4ce2bc0d93f50ab821fd2025-08-20T02:53:22ZengMDPI AGBuildings2075-53092025-02-0115572410.3390/buildings15050724Measuring Airtightness of High-Rise Buildings (Lessons Learned)Stefanie Rolfsmeier0Emanuel Mairinger1Johannes Neubig2Thomas Gayer3BlowerDoor GmbH, Zum Energie- und Umweltzentrum 1, D-31832 Springe, GermanyDr. Ronald Mischek, ZT GmbH, Donau-City-Straße 1, A-1220 Wien, AustriaStadt Wien, Magistratsabteilung 39, Rinnböckstraße 15/2, A-1110 Wien, AustriaStadt Wien, Magistratsabteilung 39, Rinnböckstraße 15/2, A-1110 Wien, AustriaMeasuring the airtightness of high-rise buildings presents significant challenges due to the effects of wind and thermal lift (stack effect). Small indoor/outdoor temperature differences, combined with the building’s height, can create substantial natural pressure differences on the building envelope, while winds induce pressure fluctuations. The international standard ISO 9972 provides insufficient guidelines for dealing with these high and fluctuating natural pressure differences. In addition, it is crucial to achieve a uniform internal pressure distribution during the test. This paper discusses the airtightness testing of high-rise buildings up to 125 m tall using portable blower door devices, following the “airtightness measurement of high-rise buildings” Passive House guideline. Differential pressure sensors were placed on the ground and top floors to record the effects of wind and thermal lift, and additional sensors helped to achieve a uniform pressure distribution within the building. The readings from the ground and top floors ensured full depressurization and pressurization during testing. The setup of the measuring fans, mainly on the ground floor, was supplemented with additional fans on higher floors to maintain pressure uniformity within a 10% tolerance. To be able to conduct a multi-point regression test, it is recommended to limit the product of the indoor/outdoor temperature difference and building height to ≤1250 mK and to achieve a coefficient of determination of 0.98 or higher, a wind speed ≤ 3 Beaufort. The study concludes that an airtight building envelope and larger internal flow paths, such as stairwells and elevator shafts, simplify the measurement.https://www.mdpi.com/2075-5309/15/5/724airtightness testhigh-rise buildingtall buildingpressure distribution within buildingair permeabilityair flow paths
spellingShingle Stefanie Rolfsmeier
Emanuel Mairinger
Johannes Neubig
Thomas Gayer
Measuring Airtightness of High-Rise Buildings (Lessons Learned)
Buildings
airtightness test
high-rise building
tall building
pressure distribution within building
air permeability
air flow paths
title Measuring Airtightness of High-Rise Buildings (Lessons Learned)
title_full Measuring Airtightness of High-Rise Buildings (Lessons Learned)
title_fullStr Measuring Airtightness of High-Rise Buildings (Lessons Learned)
title_full_unstemmed Measuring Airtightness of High-Rise Buildings (Lessons Learned)
title_short Measuring Airtightness of High-Rise Buildings (Lessons Learned)
title_sort measuring airtightness of high rise buildings lessons learned
topic airtightness test
high-rise building
tall building
pressure distribution within building
air permeability
air flow paths
url https://www.mdpi.com/2075-5309/15/5/724
work_keys_str_mv AT stefanierolfsmeier measuringairtightnessofhighrisebuildingslessonslearned
AT emanuelmairinger measuringairtightnessofhighrisebuildingslessonslearned
AT johannesneubig measuringairtightnessofhighrisebuildingslessonslearned
AT thomasgayer measuringairtightnessofhighrisebuildingslessonslearned