Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mL

Microscopic examination of urine sediment using shih-yung system requires 10ml urine volume. Pediatric patients and kidney disease patients with oliguria difficult to get 10mL urine samples, so it needs to be studied to determine the accuracy of results with smaller sample volumes. Objectives: To an...

Full description

Saved in:
Bibliographic Details
Main Authors: Putri Niawaty, Rikarni Rikarni, Dwi Yulia
Format: Article
Language:English
Published: Faculty of Medicine at Universitas Andalas 2021-09-01
Series:Jurnal Kesehatan Andalas
Online Access:http://jurnal.fk.unand.ac.id/index.php/jka/article/view/1721
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832544075835768832
author Putri Niawaty
Rikarni Rikarni
Dwi Yulia
author_facet Putri Niawaty
Rikarni Rikarni
Dwi Yulia
author_sort Putri Niawaty
collection DOAJ
description Microscopic examination of urine sediment using shih-yung system requires 10ml urine volume. Pediatric patients and kidney disease patients with oliguria difficult to get 10mL urine samples, so it needs to be studied to determine the accuracy of results with smaller sample volumes. Objectives: To analyze agreement of urine sediment examination using Shih-yung system in 10 mL and 5 mL urine volume. Methods: This study was a cross-sectional analysis of 37 urine specimens that met inclusion and exclusion criteria at the central laboratory of Dr. M. Djamil Hospital from July to September 2020. Examination of erythrocyte sediment, leukocyte sediment, and non-hyaline cast using Shih-yung system was done in 10 mL and 5 mL urine volume. Data were analyzed using kappa reliability/agreement test and significant if p<0.05. Results: Agreement test of erythrocyte sediment examination using Shih-yung system in 10ml and 5mL urine volume were moderate significantly (κ=0.600; p<0.05), agreement of leukocyte sediment examination were moderate significantly (κ=0.571; p<0.05), and agreement of nonhialin cast examination were substantial significantly (κ=0.767; p<0.05). Conclusion: Agreement test of erythrocyte and leukocyte sediment examination in 10ml and 5mL urine volume is moderate, so 5ml urine volume was not recommended. Manual examination with microscope and difference in urine sample volume causing difference sediment concentration and amount of sediment per microscope field of view. Keywords: Shih-yung,  urine sediment,  urine volume
format Article
id doaj-art-a1417ff06ba045359140a4728804d869
institution Kabale University
issn 2301-7406
2615-1138
language English
publishDate 2021-09-01
publisher Faculty of Medicine at Universitas Andalas
record_format Article
series Jurnal Kesehatan Andalas
spelling doaj-art-a1417ff06ba045359140a4728804d8692025-02-03T11:08:42ZengFaculty of Medicine at Universitas AndalasJurnal Kesehatan Andalas2301-74062615-11382021-09-01102889310.25077/jka.v10i2.17211185Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mLPutri Niawaty0Rikarni Rikarni1Dwi Yulia2Program Pendidikan Dokter Spesialis Patologi Klinik, Fakultas Kedokteran, Universitas Andalas, PadangBagian Patologi Klinik dan Kedokteran Laboratorium, Fakultas Kedokteran, Universitas Andalas, PadangBagian Patologi Klinik dan Kedokteran Laboratorium, Fakultas Kedokteran, Universitas Andalas, PadangMicroscopic examination of urine sediment using shih-yung system requires 10ml urine volume. Pediatric patients and kidney disease patients with oliguria difficult to get 10mL urine samples, so it needs to be studied to determine the accuracy of results with smaller sample volumes. Objectives: To analyze agreement of urine sediment examination using Shih-yung system in 10 mL and 5 mL urine volume. Methods: This study was a cross-sectional analysis of 37 urine specimens that met inclusion and exclusion criteria at the central laboratory of Dr. M. Djamil Hospital from July to September 2020. Examination of erythrocyte sediment, leukocyte sediment, and non-hyaline cast using Shih-yung system was done in 10 mL and 5 mL urine volume. Data were analyzed using kappa reliability/agreement test and significant if p<0.05. Results: Agreement test of erythrocyte sediment examination using Shih-yung system in 10ml and 5mL urine volume were moderate significantly (κ=0.600; p<0.05), agreement of leukocyte sediment examination were moderate significantly (κ=0.571; p<0.05), and agreement of nonhialin cast examination were substantial significantly (κ=0.767; p<0.05). Conclusion: Agreement test of erythrocyte and leukocyte sediment examination in 10ml and 5mL urine volume is moderate, so 5ml urine volume was not recommended. Manual examination with microscope and difference in urine sample volume causing difference sediment concentration and amount of sediment per microscope field of view. Keywords: Shih-yung,  urine sediment,  urine volumehttp://jurnal.fk.unand.ac.id/index.php/jka/article/view/1721
spellingShingle Putri Niawaty
Rikarni Rikarni
Dwi Yulia
Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mL
Jurnal Kesehatan Andalas
title Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mL
title_full Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mL
title_fullStr Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mL
title_full_unstemmed Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mL
title_short Uji Kesesuaian Hasil Pemeriksaan Sedimen Urine Metode Shih-Yung pada Volume Urine 10 mL dan 5 mL
title_sort uji kesesuaian hasil pemeriksaan sedimen urine metode shih yung pada volume urine 10 ml dan 5 ml
url http://jurnal.fk.unand.ac.id/index.php/jka/article/view/1721
work_keys_str_mv AT putriniawaty ujikesesuaianhasilpemeriksaansedimenurinemetodeshihyungpadavolumeurine10mldan5ml
AT rikarnirikarni ujikesesuaianhasilpemeriksaansedimenurinemetodeshihyungpadavolumeurine10mldan5ml
AT dwiyulia ujikesesuaianhasilpemeriksaansedimenurinemetodeshihyungpadavolumeurine10mldan5ml