Strength Analysis for 100% Low-floor Tram Motor Bogie Frame

The main technical parameters of a 100% low-floor tram and the main components of the motor bogie were introduced. The corresponding finite element model was established by using the finite element software ANSYS. The calculation of the load outline was listed according to the European standard EN 1...

Full description

Saved in:
Bibliographic Details
Main Authors: Yuecheng NIU, Fu LI, Jincheng LI, Fangwei LIU
Format: Article
Language:zho
Published: Editorial Department of Electric Drive for Locomotives 2019-01-01
Series:机车电传动
Subjects:
Online Access:http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2018.04.120
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The main technical parameters of a 100% low-floor tram and the main components of the motor bogie were introduced. The corresponding finite element model was established by using the finite element software ANSYS. The calculation of the load outline was listed according to the European standard EN 13749, and the static strength and fatigue strength of the motor bogie frame were calculated, as well as the modal analysis of the bogie frame was carried out. The results showed that the strength of the motor bogie frame conformed to the relevant standard, and the modal characteristics met the vehicle running requirements.
ISSN:1000-128X