Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchanger
In this study, the efficiency of a double pipe heat exchanger during a steady state laminar flow is both mathematically and numerically analysed for counter and the parallel flow configurations. The first-order and second-order upwind scheme in the Finite Volume Method are employed to obtain solutio...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2025-02-01
|
Series: | Case Studies in Thermal Engineering |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2214157X24017441 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832573234140151808 |
---|---|
author | Gizelle Rodrigues Neetu Srivastava |
author_facet | Gizelle Rodrigues Neetu Srivastava |
author_sort | Gizelle Rodrigues |
collection | DOAJ |
description | In this study, the efficiency of a double pipe heat exchanger during a steady state laminar flow is both mathematically and numerically analysed for counter and the parallel flow configurations. The first-order and second-order upwind scheme in the Finite Volume Method are employed to obtain solutions using MATLAB software. A comparison between the exact solution provided by Prasad [20] and the numerical results using the Finite Volume Method was conducted for both adiabatic and non-adiabatic conditions, demonstrating that the second-order upwind scheme showed a better analogy with low root mean square errors. Additionally, the effectiveness of the double pipe heat exchanger was calculated and plotted against the minimum heat capacity rate value for various parameters. |
format | Article |
id | doaj-art-9ff2bd90cfeb41a1a3c1a46117ed649e |
institution | Kabale University |
issn | 2214-157X |
language | English |
publishDate | 2025-02-01 |
publisher | Elsevier |
record_format | Article |
series | Case Studies in Thermal Engineering |
spelling | doaj-art-9ff2bd90cfeb41a1a3c1a46117ed649e2025-02-02T05:27:14ZengElsevierCase Studies in Thermal Engineering2214-157X2025-02-0166105713Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchangerGizelle Rodrigues0Neetu Srivastava1Department of Mathematics, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Bengaluru, 560035, IndiaCorresponding author.; Department of Mathematics, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Bengaluru, 560035, IndiaIn this study, the efficiency of a double pipe heat exchanger during a steady state laminar flow is both mathematically and numerically analysed for counter and the parallel flow configurations. The first-order and second-order upwind scheme in the Finite Volume Method are employed to obtain solutions using MATLAB software. A comparison between the exact solution provided by Prasad [20] and the numerical results using the Finite Volume Method was conducted for both adiabatic and non-adiabatic conditions, demonstrating that the second-order upwind scheme showed a better analogy with low root mean square errors. Additionally, the effectiveness of the double pipe heat exchanger was calculated and plotted against the minimum heat capacity rate value for various parameters.http://www.sciencedirect.com/science/article/pii/S2214157X2401744176R99 |
spellingShingle | Gizelle Rodrigues Neetu Srivastava Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchanger Case Studies in Thermal Engineering 76R99 |
title | Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchanger |
title_full | Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchanger |
title_fullStr | Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchanger |
title_full_unstemmed | Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchanger |
title_short | Comparative study between finite volume method and analytical method to analyse thermal efficiency of double-pipe heat exchanger |
title_sort | comparative study between finite volume method and analytical method to analyse thermal efficiency of double pipe heat exchanger |
topic | 76R99 |
url | http://www.sciencedirect.com/science/article/pii/S2214157X24017441 |
work_keys_str_mv | AT gizellerodrigues comparativestudybetweenfinitevolumemethodandanalyticalmethodtoanalysethermalefficiencyofdoublepipeheatexchanger AT neetusrivastava comparativestudybetweenfinitevolumemethodandanalyticalmethodtoanalysethermalefficiencyofdoublepipeheatexchanger |