Basic Principles on Rational Heat Utilization from Industrial Furnace Surfaces
The executed analysis has shown that high operational temperature of 200–400 оС in the area of outside furnace surface can be decreased up to safety level by selection of dimensions and thermal and physical properties of heat insulation materials and due observation of some boundary conditions. Meth...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
Belarusian National Technical University
2011-02-01
|
| Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
| Online Access: | https://energy.bntu.by/jour/article/view/309 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|