Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves

In this article, the mechanical properties of the steel bars connected by the full-grouted sleeve with grouting defects were investigated experimentally. The study focused on two defect factors: the insufficiency of grouting material strength and the lack of grouting fullness. The HRB400 steel bar w...

Full description

Saved in:
Bibliographic Details
Main Authors: Fei Guo, Junhua Li, Sicong He, Chunheng Zhou
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2022/5036505
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832563857774608384
author Fei Guo
Junhua Li
Sicong He
Chunheng Zhou
author_facet Fei Guo
Junhua Li
Sicong He
Chunheng Zhou
author_sort Fei Guo
collection DOAJ
description In this article, the mechanical properties of the steel bars connected by the full-grouted sleeve with grouting defects were investigated experimentally. The study focused on two defect factors: the insufficiency of grouting material strength and the lack of grouting fullness. The HRB400 steel bar with a diameter of 20 mm and the full-grouted sleeve with the model of GTQ4J 16 were applied in the experiment. The mechanical properties of the steel bar connected by grouted sleeve under different conditions were tested under tensile load, and these mechanical parameters were compared with the standard values in the specification. The results show that both kinds of grouting defects have a significant impact on the mechanical properties of reinforcement. The tensile strength and elongation of the joint were decreased with the decrease of the strength of the grouting material. When the water-binder ratio reaches 0.14, the strength of the grouting material is 66.4 MPa, and the mechanical properties of the joint cannot meet the requirements. At the same time, the mechanical properties of the joints were also reduced with the decrease of the grouting fullness. When the grouting fullness is below 80%, the tensile strength decreased more obviously than before, and the mechanical properties cannot reach the relevant standard.
format Article
id doaj-art-9a3b3511986d4bb2b596038f5178c71e
institution Kabale University
issn 1687-8094
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-9a3b3511986d4bb2b596038f5178c71e2025-02-03T01:12:22ZengWileyAdvances in Civil Engineering1687-80942022-01-01202210.1155/2022/5036505Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted SleevesFei Guo0Junhua Li1Sicong He2Chunheng Zhou3School of Civil and Environmental EngineeringSchool of Civil and Environmental EngineeringSchool of Civil and Environmental EngineeringSchool of Civil and Environmental EngineeringIn this article, the mechanical properties of the steel bars connected by the full-grouted sleeve with grouting defects were investigated experimentally. The study focused on two defect factors: the insufficiency of grouting material strength and the lack of grouting fullness. The HRB400 steel bar with a diameter of 20 mm and the full-grouted sleeve with the model of GTQ4J 16 were applied in the experiment. The mechanical properties of the steel bar connected by grouted sleeve under different conditions were tested under tensile load, and these mechanical parameters were compared with the standard values in the specification. The results show that both kinds of grouting defects have a significant impact on the mechanical properties of reinforcement. The tensile strength and elongation of the joint were decreased with the decrease of the strength of the grouting material. When the water-binder ratio reaches 0.14, the strength of the grouting material is 66.4 MPa, and the mechanical properties of the joint cannot meet the requirements. At the same time, the mechanical properties of the joints were also reduced with the decrease of the grouting fullness. When the grouting fullness is below 80%, the tensile strength decreased more obviously than before, and the mechanical properties cannot reach the relevant standard.http://dx.doi.org/10.1155/2022/5036505
spellingShingle Fei Guo
Junhua Li
Sicong He
Chunheng Zhou
Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves
Advances in Civil Engineering
title Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves
title_full Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves
title_fullStr Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves
title_full_unstemmed Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves
title_short Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves
title_sort experimental study on the effect of grouting defects on mechanical properties of the rebar connected by full grouted sleeves
url http://dx.doi.org/10.1155/2022/5036505
work_keys_str_mv AT feiguo experimentalstudyontheeffectofgroutingdefectsonmechanicalpropertiesoftherebarconnectedbyfullgroutedsleeves
AT junhuali experimentalstudyontheeffectofgroutingdefectsonmechanicalpropertiesoftherebarconnectedbyfullgroutedsleeves
AT siconghe experimentalstudyontheeffectofgroutingdefectsonmechanicalpropertiesoftherebarconnectedbyfullgroutedsleeves
AT chunhengzhou experimentalstudyontheeffectofgroutingdefectsonmechanicalpropertiesoftherebarconnectedbyfullgroutedsleeves