Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital Building

Operational modal analysis is a robust and practical approach to structural health monitoring which assumes white noise as input. Therefore, the accuracy of this method can be compromised when dealing with colored unknown excitations, in which, for example, harmonic loads induced by the operation of...

Full description

Saved in:
Bibliographic Details
Main Authors: C. Rinaldi, A. Talebi, M. D’Alessio, F. Potenza, V. Gattulli
Format: Article
Language:English
Published: Wiley 2024-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2024/4447739
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832564135993278464
author C. Rinaldi
A. Talebi
M. D’Alessio
F. Potenza
V. Gattulli
author_facet C. Rinaldi
A. Talebi
M. D’Alessio
F. Potenza
V. Gattulli
author_sort C. Rinaldi
collection DOAJ
description Operational modal analysis is a robust and practical approach to structural health monitoring which assumes white noise as input. Therefore, the accuracy of this method can be compromised when dealing with colored unknown excitations, in which, for example, harmonic loads induced by the operation of mechanical equipment, may affect the modal parameter estimation. This study aims to address the challenge of identifying both natural and forcing frequencies of a complex building by exploiting the potentiality of both the spectral kurtosis analysis and stochastic subspace identification technique. The first one is based on the evaluation of a statistical quantity characterized by low values when data are stationary and Gaussian and high values when specific frequencies and nonstationarity are present in the signals. It allows the detection of harmonics, transients, and repetitive impulses in the frequency domain. Its combined use with the stochastic subspace identification technique enables us to effectively identify and separate harmonic-induced vibrations from structural response to ambient white noise. This approach can lead to a more accurate modal parameter estimation that has been investigated in this work through numerical and experimental analyses carried out on the Cardinal Massaia hospital building in Asti, Italy. An experimental daily dynamic campaign has been carried out to acquire accelerations in operational conditions including disturbances due to machinery like elevators and air conditioners. The combined use of kurtosis analysis and stochastic subspace identification techniques has been used to process a large dataset of noisy measurements acquired in operational conditions. Five different measurement setups have been implemented, each one composed of 14 sensors. Notwithstanding the complexity of the case study under investigation for both the structural configuration and difficulties in the experimental data acquisition, this approach allowed to distinguish natural from forcing frequencies, highlighting its accuracy and robustness.
format Article
id doaj-art-9a2e208f6b394589b56959a3fd9693e3
institution Kabale University
issn 1687-8094
language English
publishDate 2024-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-9a2e208f6b394589b56959a3fd9693e32025-02-03T01:11:42ZengWileyAdvances in Civil Engineering1687-80942024-01-01202410.1155/2024/4447739Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital BuildingC. Rinaldi0A. Talebi1M. D’Alessio2F. Potenza3V. Gattulli4Department of Structural and Geotechnical EngineeringDepartment of Structural and Geotechnical EngineeringDepartment of Structural and Geotechnical EngineeringDepartment of Engineering and GeologyDepartment of Structural and Geotechnical EngineeringOperational modal analysis is a robust and practical approach to structural health monitoring which assumes white noise as input. Therefore, the accuracy of this method can be compromised when dealing with colored unknown excitations, in which, for example, harmonic loads induced by the operation of mechanical equipment, may affect the modal parameter estimation. This study aims to address the challenge of identifying both natural and forcing frequencies of a complex building by exploiting the potentiality of both the spectral kurtosis analysis and stochastic subspace identification technique. The first one is based on the evaluation of a statistical quantity characterized by low values when data are stationary and Gaussian and high values when specific frequencies and nonstationarity are present in the signals. It allows the detection of harmonics, transients, and repetitive impulses in the frequency domain. Its combined use with the stochastic subspace identification technique enables us to effectively identify and separate harmonic-induced vibrations from structural response to ambient white noise. This approach can lead to a more accurate modal parameter estimation that has been investigated in this work through numerical and experimental analyses carried out on the Cardinal Massaia hospital building in Asti, Italy. An experimental daily dynamic campaign has been carried out to acquire accelerations in operational conditions including disturbances due to machinery like elevators and air conditioners. The combined use of kurtosis analysis and stochastic subspace identification techniques has been used to process a large dataset of noisy measurements acquired in operational conditions. Five different measurement setups have been implemented, each one composed of 14 sensors. Notwithstanding the complexity of the case study under investigation for both the structural configuration and difficulties in the experimental data acquisition, this approach allowed to distinguish natural from forcing frequencies, highlighting its accuracy and robustness.http://dx.doi.org/10.1155/2024/4447739
spellingShingle C. Rinaldi
A. Talebi
M. D’Alessio
F. Potenza
V. Gattulli
Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital Building
Advances in Civil Engineering
title Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital Building
title_full Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital Building
title_fullStr Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital Building
title_full_unstemmed Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital Building
title_short Identification of Natural and Forcing Frequencies through Noisy Measurements Acquired in Operational Conditions on a Hospital Building
title_sort identification of natural and forcing frequencies through noisy measurements acquired in operational conditions on a hospital building
url http://dx.doi.org/10.1155/2024/4447739
work_keys_str_mv AT crinaldi identificationofnaturalandforcingfrequenciesthroughnoisymeasurementsacquiredinoperationalconditionsonahospitalbuilding
AT atalebi identificationofnaturalandforcingfrequenciesthroughnoisymeasurementsacquiredinoperationalconditionsonahospitalbuilding
AT mdalessio identificationofnaturalandforcingfrequenciesthroughnoisymeasurementsacquiredinoperationalconditionsonahospitalbuilding
AT fpotenza identificationofnaturalandforcingfrequenciesthroughnoisymeasurementsacquiredinoperationalconditionsonahospitalbuilding
AT vgattulli identificationofnaturalandforcingfrequenciesthroughnoisymeasurementsacquiredinoperationalconditionsonahospitalbuilding