Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regions

Abstract High-speed trains bring cold air into tunnels, significantly affecting the temperature field in cold-region tunnels, leading to risks of lining freeze-thaw damage, track deformation, and safety hazards, which is detrimental to thermal insulation design. Using the Kunlunshan Tunnel as a case...

Full description

Saved in:
Bibliographic Details
Main Authors: Jun Zhou, Liyuan Wu, Yan Gao, Xu Chen, Rongrong Liu
Format: Article
Language:English
Published: Nature Portfolio 2025-08-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-025-16068-4
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849226290740068352
author Jun Zhou
Liyuan Wu
Yan Gao
Xu Chen
Rongrong Liu
author_facet Jun Zhou
Liyuan Wu
Yan Gao
Xu Chen
Rongrong Liu
author_sort Jun Zhou
collection DOAJ
description Abstract High-speed trains bring cold air into tunnels, significantly affecting the temperature field in cold-region tunnels, leading to risks of lining freeze-thaw damage, track deformation, and safety hazards, which is detrimental to thermal insulation design. Using the Kunlunshan Tunnel as a case study and based on unsteady flow theory, this study constructed the Navier-Stokes equations and proposed a theoretical calculation method for train-induced airflow. Dynamic mesh technology was adopted to develop an “equivalent wind speed” train-induced-airflow-temperature coupling computational model. The main idea of this model is to divide the effect of external wind speed on the tunnel into three distinct phases: the train-induced airflow phase, the residual airflow phase, and the natural wind phase. During each phase, the changes in wind speed are governed by the principle of conservation of cold air volume and converted into a steady airflow equivalent for that specific phase. This model was used to investigate the effects of train frequency, ground temperature of surrounding rock, external temperature, and external wind speed on the temperature field variation in single-track high-speed railway tunnels in cold regions. After verification, the temperature field inside the tunnel calculated by the “equivalent wind speed” method was in good agreement with the measured data, and can be used for subsequent numerical simulation calculations. The results show that when the interval between two trains is less than 20 min, the average temperature in the tunnel decreases by approximately 1.71 ℃ due to the significant impact of train-induced airflow. The impact of the ground temperature of surrounding rock on the longitudinal temperature gradient in cold-region tunnels ranges from 0.059 ℃ to 1.13 ℃ for every 100 m, and the ranges for external temperature and external wind speed are 0.080 ℃ to 2.286 ℃ and 0.002 ℃ to 1.134 ℃, respectively.
format Article
id doaj-art-99c9c74ee7b94e9ebe440a25b7dd3d0c
institution Kabale University
issn 2045-2322
language English
publishDate 2025-08-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-99c9c74ee7b94e9ebe440a25b7dd3d0c2025-08-24T11:30:01ZengNature PortfolioScientific Reports2045-23222025-08-0115111310.1038/s41598-025-16068-4Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regionsJun Zhou0Liyuan Wu1Yan Gao2Xu Chen3Rongrong Liu4Huaiyin Institute of TechnologyHuaiyin Institute of TechnologyHuaiyin Institute of TechnologyHuaiyin Institute of TechnologyHuaiyin Institute of TechnologyAbstract High-speed trains bring cold air into tunnels, significantly affecting the temperature field in cold-region tunnels, leading to risks of lining freeze-thaw damage, track deformation, and safety hazards, which is detrimental to thermal insulation design. Using the Kunlunshan Tunnel as a case study and based on unsteady flow theory, this study constructed the Navier-Stokes equations and proposed a theoretical calculation method for train-induced airflow. Dynamic mesh technology was adopted to develop an “equivalent wind speed” train-induced-airflow-temperature coupling computational model. The main idea of this model is to divide the effect of external wind speed on the tunnel into three distinct phases: the train-induced airflow phase, the residual airflow phase, and the natural wind phase. During each phase, the changes in wind speed are governed by the principle of conservation of cold air volume and converted into a steady airflow equivalent for that specific phase. This model was used to investigate the effects of train frequency, ground temperature of surrounding rock, external temperature, and external wind speed on the temperature field variation in single-track high-speed railway tunnels in cold regions. After verification, the temperature field inside the tunnel calculated by the “equivalent wind speed” method was in good agreement with the measured data, and can be used for subsequent numerical simulation calculations. The results show that when the interval between two trains is less than 20 min, the average temperature in the tunnel decreases by approximately 1.71 ℃ due to the significant impact of train-induced airflow. The impact of the ground temperature of surrounding rock on the longitudinal temperature gradient in cold-region tunnels ranges from 0.059 ℃ to 1.13 ℃ for every 100 m, and the ranges for external temperature and external wind speed are 0.080 ℃ to 2.286 ℃ and 0.002 ℃ to 1.134 ℃, respectively.https://doi.org/10.1038/s41598-025-16068-4Cold-region engineeringSingle-track tunnelTrain-induced airflowTemperature fieldAnalytical solution
spellingShingle Jun Zhou
Liyuan Wu
Yan Gao
Xu Chen
Rongrong Liu
Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regions
Scientific Reports
Cold-region engineering
Single-track tunnel
Train-induced airflow
Temperature field
Analytical solution
title Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regions
title_full Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regions
title_fullStr Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regions
title_full_unstemmed Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regions
title_short Study on effects of the train-induced airflow on the temperature field of single-track high-speed railway tunnels in cold regions
title_sort study on effects of the train induced airflow on the temperature field of single track high speed railway tunnels in cold regions
topic Cold-region engineering
Single-track tunnel
Train-induced airflow
Temperature field
Analytical solution
url https://doi.org/10.1038/s41598-025-16068-4
work_keys_str_mv AT junzhou studyoneffectsofthetraininducedairflowonthetemperaturefieldofsingletrackhighspeedrailwaytunnelsincoldregions
AT liyuanwu studyoneffectsofthetraininducedairflowonthetemperaturefieldofsingletrackhighspeedrailwaytunnelsincoldregions
AT yangao studyoneffectsofthetraininducedairflowonthetemperaturefieldofsingletrackhighspeedrailwaytunnelsincoldregions
AT xuchen studyoneffectsofthetraininducedairflowonthetemperaturefieldofsingletrackhighspeedrailwaytunnelsincoldregions
AT rongrongliu studyoneffectsofthetraininducedairflowonthetemperaturefieldofsingletrackhighspeedrailwaytunnelsincoldregions