Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous Samples

In the development of new technologies, sophisticated materials often require a highly pure inert atmospheres, for example with less than 1 ppm of oxygen and moisture. Additionally, special protection for operators is frequently necessary due to the health and environmental risks posed by these mat...

Full description

Saved in:
Bibliographic Details
Main Authors: Nick Brierley, Darius Zanke, Luke Peche, Peter Habenschaden
Format: Article
Language:deu
Published: NDT.net 2025-02-01
Series:e-Journal of Nondestructive Testing
Online Access:https://www.ndt.net/search/docs.php3?id=30721
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832086585093390336
author Nick Brierley
Darius Zanke
Luke Peche
Peter Habenschaden
author_facet Nick Brierley
Darius Zanke
Luke Peche
Peter Habenschaden
author_sort Nick Brierley
collection DOAJ
description In the development of new technologies, sophisticated materials often require a highly pure inert atmospheres, for example with less than 1 ppm of oxygen and moisture. Additionally, special protection for operators is frequently necessary due to the health and environmental risks posed by these materials. To address this need, diondo and MBRAUN have been collaborating to develop an X-ray CT scanner system that allows reactive or hazardous materials to be scanned in a highly sealed inert atmosphere. The innovative setup merges a diondo CT system with an MBRAUN glovebox. With a leakage rate of Class 1 according to ISO 10684-2, the glovebox functions as an ultra-tight containment, ensuring the integrity and safety needed for handling challenging materials, whilst the radiation enclosure ensures operators and bystanders are protected from X-rays during scanning. Combining the two forms of containment with the X-ray imaging chain is non-trivial, especially considering sample manipulation, ergonomics and maintenance. This contribution will describe the solutions adopted to meet these challenges.
format Article
id doaj-art-98f981d008674ac289add8381d2494f4
institution Kabale University
issn 1435-4934
language deu
publishDate 2025-02-01
publisher NDT.net
record_format Article
series e-Journal of Nondestructive Testing
spelling doaj-art-98f981d008674ac289add8381d2494f42025-02-06T10:48:18ZdeuNDT.nete-Journal of Nondestructive Testing1435-49342025-02-0130210.58286/30721Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous SamplesNick Brierleyhttps://orcid.org/0000-0002-4398-0884Darius ZankeLuke PechePeter Habenschaden In the development of new technologies, sophisticated materials often require a highly pure inert atmospheres, for example with less than 1 ppm of oxygen and moisture. Additionally, special protection for operators is frequently necessary due to the health and environmental risks posed by these materials. To address this need, diondo and MBRAUN have been collaborating to develop an X-ray CT scanner system that allows reactive or hazardous materials to be scanned in a highly sealed inert atmosphere. The innovative setup merges a diondo CT system with an MBRAUN glovebox. With a leakage rate of Class 1 according to ISO 10684-2, the glovebox functions as an ultra-tight containment, ensuring the integrity and safety needed for handling challenging materials, whilst the radiation enclosure ensures operators and bystanders are protected from X-rays during scanning. Combining the two forms of containment with the X-ray imaging chain is non-trivial, especially considering sample manipulation, ergonomics and maintenance. This contribution will describe the solutions adopted to meet these challenges. https://www.ndt.net/search/docs.php3?id=30721
spellingShingle Nick Brierley
Darius Zanke
Luke Peche
Peter Habenschaden
Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous Samples
e-Journal of Nondestructive Testing
title Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous Samples
title_full Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous Samples
title_fullStr Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous Samples
title_full_unstemmed Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous Samples
title_short Glovebox-CT to Enable 3D Imaging of Reactive or Hazardous Samples
title_sort glovebox ct to enable 3d imaging of reactive or hazardous samples
url https://www.ndt.net/search/docs.php3?id=30721
work_keys_str_mv AT nickbrierley gloveboxcttoenable3dimagingofreactiveorhazardoussamples
AT dariuszanke gloveboxcttoenable3dimagingofreactiveorhazardoussamples
AT lukepeche gloveboxcttoenable3dimagingofreactiveorhazardoussamples
AT peterhabenschaden gloveboxcttoenable3dimagingofreactiveorhazardoussamples